DTG 1300 Eco.NOx Plus / V130DTG(E) 130 Eco.NOx Plus
Gas fired condensing boiler
ELIDENS
User Guide
8538N045-B
300002784-001-F
EN
Страница 1: ...DTG 1300 Eco NOx Plus V130 DTG E 130 Eco NOx Plus Gas fired condensing boiler ELIDENS User Guide 8538N045 B 300002784 001 F EN...
Страница 2: ...ecommendations 3 2 1 Aeration 4 2 1 1 Chimney versions 4 2 1 2 Forced flue versions 4 2 2 Maintenance 4 2 3 Adapting to another gas type 4 3 Description 5 3 1 Boilers 5 3 2 Control panel 8 4 Energy sa...
Страница 3: ...ting of the boiler follow carefully the instructions Any intervention on the appliance and heating equipment must be carried out by a qualified technician The manufacturer is not liable for any improp...
Страница 4: ...alled must comply with the standards in force in the country 2 1 2 Forced flue versions It is not necessary to provide ventilation of the premises in which the boiler is installed Ventilation is requi...
Страница 5: ...ndensing boiler module 2 Electronic manometer 3 Automatic air vent 4 Expansion vessel 12 litres 5 Siphon 6 Modulating pump 7 Safety valve 3 bar 8 Inverter valve 9 Stop cock 10 Domestic hot water safet...
Страница 6: ...on vessel 12 litres 5 Siphon 6 Modulating pump 7 Safety valve 3 bar 8 Inverter valve 9 Stop cock 10 Domestic hot water safety valve 7 bar 11 Non return valve 12 Disconnector 13 Funnel 14 Domestic hot...
Страница 7: ...3 Siphon 4 Heating return 5 Condensates discharge 6 Heating outlet 7 Gas 1 Condensing boiler module 15 kW 25 kW 2 Electronic manometer 3 Automatic air vent 4 Expansion vessel 12 litres 5 Siphon 6 Mod...
Страница 8: ...4 16 18 20 22 24 A 2 4 SUNDAY 04 1 Main ON OFF switch 2 On light Alarm Red LED lit Burner in safety condition Flashing red Led abnormal operation 3 Safety control box reset button 4 Timed circuit brea...
Страница 9: ...mme display P1 P2 P3 P4 or E Summer mode activated 8 The arrows flash when setting values can be modified using the and keys 9 Circuit operation symbols A B C Opening the 3 way valve Closing the 3 way...
Страница 10: ...ature 2 Reduced temperature 2 Domestic hot water temperature Is used to adjust the selected temperature Operating mode selection keys AUTO Heating according to the time programme Forced Comfort mode u...
Страница 11: ...R Standard programme key Reset of all time programmes K Fitter settings access key Key for access to setting and measurements J Page scrolling I Line scrolling H Back to the title or the previous lin...
Страница 12: ...the exhaust gases perceptible but also takes advantage of latent heat hidden This energy is extracted from the steam produced during the combustion process and is not exploited by conventional boiler...
Страница 13: ...ling your fitter The burner is not working It is cold If using a remote control CDI2 or FM52 check that it is set according to the instructions It is cold There is no domestic hot water Check the temp...
Страница 14: ...lve control in the safety control box is defective CVI10 22 FAILURE Internal safety control box fault CVI COM FAULT Communication error between DIEMATIC and safety control box MANOMETRE FAIL Fault on...
Страница 15: ...ding dispositions are not exclusive of benefits for the purchaser of the legal guarantee as stated in Civil Code articles 1641 to 1648 Poland Warranty conditions are included in the warranty card Swit...
Страница 16: ...282 EMSDETTEN 49 0 25 72 23 5 49 0 25 72 23 102 info dedietrich de Weggevoerdenlaan 5 B 8500 KORTRIJK 32 0 56 23 75 11 Bahnstrasse 24 CH 8603 SCHWERZENBACH 41 0 44 806 44 24 41 0 44 806 44 25 39 rue J...