Series configuration

(See page 7 for single heater)

9. Stop valve

28. Cold water supply pipe
29. Pressure reducing valve
30. Safety unit set to 7 bars

a. Cold water inlet including a non-return valve
b. Connection to the calorifier cold water inlet.
c. Stop valve.
d. valve and manual drain.
e. Drain orifice.

54. YA type load break (health regulations).
57. Hot water outlet

Note: Vertical wall-mounted waters shown on page 4 may also be fitted in
series, along the same principle.

8. Packaging

Cor-émail electric water heaters are supplied in cardboard packa-
ging. They are protected by moulded polystyrene packing pieces
(except 400 and 500 l floor-standing models, which are delivered on
a wooden pallet with cardboard strapping).

The table below provides the dimensions and weights of each hea-
ter model after packaging.

Optional features:

- For 10, 15 and 30 litre Compact heaters: mixing taps for inlet controlled heaters
- For 75 -200 litre standard vertical heaters: stand for standard vertical wall-mounted heaters

20

100

°

C

20

100

°

C

20

100

°

C

20

100

°

C

9

29

28

57

30
a

b

c

d

e

2 cm

(54)

28

57

30
a

b

c

d

e

2 cm

(54)

8978F011

7. Assembly of the insulation connector delivered with the water heater

- standard wall-mounted water heaters - p. 4

- horizontal water heaters - p. 5

- free-standing water heaters (except 400 and 500 l) - p. 6

The connection of a water heater to copper mains pipes must be
done using the intercalation of the insulation connector, if this is
delivered with the appliance, or with reduced or equal male/female
sleeves in cast iron, if this is not the case. The connector provided
is intended to be connected to the hot water outlet, the safety
control unit being connected directly to the cold water inlet pipe on
the water heater. If this is not the case and copper mains pipes form
the junction between the cold water pipe and the safety control unit,
it is essential that a sleeve is also intercalated. For example,
sleeves in malleable cast iron may be used (Right – Right 270). If
the threading on pipes not fitted with this protection is corroded, our
guarantee may not be invoked.

Domestic hot 
water outlet

Fiber seal

Insulation connector

Fiber seal

Domestic hot 
water outlet pipe

8978F015

8971Q011

Type COMPACT

STANDARD 

WALL-

HORIZONTAL

of heater

MOUNTED VERTICAL

Capacity

litres

10*

15*

30

50

75

100

150

200

75

100

150

200

Width

mm

305

340

395

570

570

570

570

570

570

570

570

570

Depth

mm

305

340

395

570

570

570

570

570

570

570

570

570

Height

mm

500

555

683

615

805

937

1281

1605

721

890

1212

1539

Weight

kg

9

11

16

24

30

35

45

54

30

35

45

56

FREE-STANDING

150

200

250

300

400

500

570

570

600

600

790

790

570

570

610

610

790

790

1248

1575

1616

1840

1865

2218

45

56

67

76

150

172

Содержание Cor-email

Страница 1: ...plications D E D I E T R I C H T H E R M I Q U E Société Anonyme au Capital de 21 686 370 Euros BOITE POSTALE 30 57 RUE DE LA GARE F 67580 MERTZWILLER TELEPHONE 03 88 80 27 00 FAX 03 88 80 27 99 Vertical wall mounted water heaters 50 200 litre standard heaters p 4 These highly aesthetic heaters may be mounted on a wall or placed on a stand Thanks to their small dimensions they may also be fitted i...

Страница 2: ...ermostats of all heaters are factory set at 65 C Selecting the water heater Hot water needs are not easy to assess as they increase very rapidly as users get used to this major convenience As a result the recommended capacity should be much greater than existing needs Daily needs Supply point Number of people hot water at 60 C Recommended capacity in the household days of normal use days of increa...

Страница 3: ...guarantee to operate We recommend the use of diaphragm type hydraulic safety units bearing the NF mark A pressure reducing valve must be fitted if the supply pressure is greater than 5 5 bar Examples of installation Type of heater COMPACT HEATER COMPACT HEATER for low mounting for overhead mounting Capacity litres 10 15 10 15 30 Dimensions of AFY 40 cast female 1 2 ron pipe joints in inches male 3...

Страница 4: ...CAL WALL MOUNTED HEATER Capacity litres 50 75 100 150 200 Power supply single single single single multiple single multiple Section mm2 1 5 1 5 1 5 1 5 1 5 2 5 2 5 Single phase 230 V Intensity Amp 3 9 5 2 5 2 7 8 7 8 10 4 10 4 Section mm2 1 5 1 5 Three phase 230 V Intensity Amp 4 5 6 Section mm2 1 5 1 5 Three phase 400 V Intensity Amp 2 6 3 5 Hydraulic connections The connections are marked with b...

Страница 5: ...2 6 3 Three phase 400 V Intensity Amp 2 6 3 Hydraulic connections The connections are marked with blue cold water and red hot water discs Fitting a stop valve on the cold water supply pipe is compulsory Safety rules require that a lead sealed safety valve calibrated to 7 bar must necessarily be fitted on the cold water supply pipe for the guarantee to operate We recommend the use of diaphragm type...

Страница 6: ...ected directly to copper or brass With 400 and 500 L heaters connection to copper piping must necessarily be done via cast iron male female reducing or non reducing pipe joints for the guarantee to operate E g _ or 1 AFY 40 pipe joints for 400 litre hea ters and 1 joints for 500 litre heaters 6 Free standing water heaters Type of water heater FREE STANDING HEATER Nominal capacity litres 150 200 25...

Страница 7: ...eaters p 5 free standing water heaters except 400 and 500 l p 6 The connection of a water heater to copper mains pipes must be done using the intercalation of the insulation connector if this is delivered with the appliance or with reduced or equal male female sleeves in cast iron if this is not the case The connector provided is intended to be connected to the hot water outlet the safety control ...

Страница 8: ...mounted vertical horizontal and floor standing water heaters except 400 and 500 l are fitted with the ACI system active and permanent protection of the tank against corrosion using a titanium anode which does not dissolve over time and requires no mainte nance Important Check the correct operation of the safety unit see ins tructions for use from time to time at least once a month Do not worry if ...

Отзывы: