5. Horizontal water heaters

Type of water heater

HORIZONTAL HEATER

Nominal capacity

litres

75

100

150

200

Nominal capacity

watts

1200

1800

1800

2100

Heating time (1)

4:30 hr.

3:20 hr.

4:45 hr.

4:55 hr.

Maintaining consumption

kWh per 24 hours at 65˚C (2)

1.01

1.09

1.28

1.70

Cooling constant

Wh per 24 hours / litre / ˚C

0.31

0.29

0.22

0.20

Main dimensions

A

mm

480

600

800

1050

L

mm

691

860

1182

1509

Weight without water

kg

33

39

50

61

(1) As per standard NFC 73 221 (15˚C to 65˚C). 
(2) As per French Standard.

Fastening

Horizontal water heaters are fastened with 4 bolts, dia. 10, sealed
into the wall.
A drilling template is supplied with the unit to make it easier to mark
the drilling holes without any need to take measurements.
Horizontal water heaters may be fastened to a wall or the ceiling. In
either case, the connections may be placed to the left or right-hand
side of the heater.

Electrical connections

Horizontal wall-mounted water heaters are designed for a single-
phase 230 VAC power supply. The coupling of multiple voltage hea-
ters is user-modifiable, and may also be set for three-phase 230 V
or 400 V power supplies.
Grounding the metal parts (with the special terminal on the unit) is
compulsory. The section of the line, the omnipole breaking device
and the protection system (fuses or circuit-breakers) shall be selec-
ted in keeping with applicable standards, depending upon the input
intensity, voltage and power.

Note: The heaters must necessarily be connected to a fixed piping system. In prin-
ciple, power will be supplied to the heater at night, manually or automatically with
the help of a clock supplied by the electricity company. In this way, the water is hea-
ted when the reduced off-peak rate is charged for electricity. The unit may be fitted
with a switch for supplying power in the daytime, when the full rate is charged.

Type of water heater

HORIZONTAL HEATER

Capacity

litres

75

100

150

200

Power supply

single multiple multiple multiple

Section

mm

2

1,5

1,5

1,5

2,5

Single-phase 230 V

Intensity

Amp

5,2

7,8

7,8

10,4

Section

mm

2

1,5

1,5

Three-phase 230 V

Intensity

Amp

4,5

5,3

Section

mm

2

2,6

3

Three-phase 400 V

Intensity

Amp

2,6

3

Hydraulic connections

The connections are marked with blue (cold water) and red (hot
water) discs. Fitting a stop valve on the cold water supply pipe is
compulsory.

Safety rules require that a lead-sealed safety valve calibrated to 7
bar must necessarily be fitted on the cold water supply pipe (for the
guarantee to operate). We recommend the use of diaphragm type
hydraulic safety units bearing the NF mark. 

A pressure reducing

valve must be fitted if the supply pressure is greater than 5.5 bar.

Example of installation

Pressurised heater

Type of heater

HORIZONTAL HEATER

Capacity

litres

75

100

150

200

14 x 16

Copper pipe dimensions

mm

12 x 14 or 14 x 16

or

16 x 18

Note : The composite material connecting piece (supplied in a bag) is to be
fitted on the hot water outlet of the heater. It is used to prevent the formation
of a galvanic couple, which can lead to the corrosion of the connection
threads when the heater is connected directly to copper or brass.

;;

@@

;;

yy

;;

;;

@@

@@

;;

;;

yy

yy

;;

;;

@@

@@

;;

;;

yy

yy

Vitreous enamel
with a high quartz
content, resistant to
the most corrosive
water

Imposed current
titanium anode

Thick metal tank
(test pressure
12 bar)

Thimble tube
thermostat

Lacquered white
cladding, curved
square shape

Heating element
made up of an
enclosed resistor on
a steatite support,
accessible without
draining the heater

Mulitpole voltage power
supply connection (except
75 and 100 L models,
single-phase 230 V)

Adjustable thermostat with
built-in thermal safety
device

Hot water outlet pipe
(stainless steel)

Cold water supply
pipe with anti-splash
plug (stainless steel)

Rigid injected
polyurethane foam
insulating material
(0 % CFC)

8971Q008

min. support height 300
(not supplied)

on the floor

on an wall

on the ceiling

L

A

30

120

490

100

505

440

275

530

580

600

440

275

691

480

30

195

254

90

505

cold water

supply R 3/4

hot water

outlet R 3/4

hot water

outlet R 3/4

cold water

supply R 3/4

8978F014

8978F002A

75 l

100-150-200 l

9. Stop valve

28. Cold water supply pipe
29. Pressure reducing valve
30. Safety unit set to 7 bars

a. Cold water inlet including

a non-return valve

b. Connection to the calori-

fier cold water inlet.

c. Stop valve.
d. valve and manual drain.
e. Drain orifice.

54. YA type load break (heal-

th regulations).

57. Hot water outlet

9

29

57

28

b

c

d

e

2 cm

(54)

30

a

8978F001

Содержание Cor-email

Страница 1: ...plications D E D I E T R I C H T H E R M I Q U E Société Anonyme au Capital de 21 686 370 Euros BOITE POSTALE 30 57 RUE DE LA GARE F 67580 MERTZWILLER TELEPHONE 03 88 80 27 00 FAX 03 88 80 27 99 Vertical wall mounted water heaters 50 200 litre standard heaters p 4 These highly aesthetic heaters may be mounted on a wall or placed on a stand Thanks to their small dimensions they may also be fitted i...

Страница 2: ...ermostats of all heaters are factory set at 65 C Selecting the water heater Hot water needs are not easy to assess as they increase very rapidly as users get used to this major convenience As a result the recommended capacity should be much greater than existing needs Daily needs Supply point Number of people hot water at 60 C Recommended capacity in the household days of normal use days of increa...

Страница 3: ...guarantee to operate We recommend the use of diaphragm type hydraulic safety units bearing the NF mark A pressure reducing valve must be fitted if the supply pressure is greater than 5 5 bar Examples of installation Type of heater COMPACT HEATER COMPACT HEATER for low mounting for overhead mounting Capacity litres 10 15 10 15 30 Dimensions of AFY 40 cast female 1 2 ron pipe joints in inches male 3...

Страница 4: ...CAL WALL MOUNTED HEATER Capacity litres 50 75 100 150 200 Power supply single single single single multiple single multiple Section mm2 1 5 1 5 1 5 1 5 1 5 2 5 2 5 Single phase 230 V Intensity Amp 3 9 5 2 5 2 7 8 7 8 10 4 10 4 Section mm2 1 5 1 5 Three phase 230 V Intensity Amp 4 5 6 Section mm2 1 5 1 5 Three phase 400 V Intensity Amp 2 6 3 5 Hydraulic connections The connections are marked with b...

Страница 5: ...2 6 3 Three phase 400 V Intensity Amp 2 6 3 Hydraulic connections The connections are marked with blue cold water and red hot water discs Fitting a stop valve on the cold water supply pipe is compulsory Safety rules require that a lead sealed safety valve calibrated to 7 bar must necessarily be fitted on the cold water supply pipe for the guarantee to operate We recommend the use of diaphragm type...

Страница 6: ...ected directly to copper or brass With 400 and 500 L heaters connection to copper piping must necessarily be done via cast iron male female reducing or non reducing pipe joints for the guarantee to operate E g _ or 1 AFY 40 pipe joints for 400 litre hea ters and 1 joints for 500 litre heaters 6 Free standing water heaters Type of water heater FREE STANDING HEATER Nominal capacity litres 150 200 25...

Страница 7: ...eaters p 5 free standing water heaters except 400 and 500 l p 6 The connection of a water heater to copper mains pipes must be done using the intercalation of the insulation connector if this is delivered with the appliance or with reduced or equal male female sleeves in cast iron if this is not the case The connector provided is intended to be connected to the hot water outlet the safety control ...

Страница 8: ...mounted vertical horizontal and floor standing water heaters except 400 and 500 l are fitted with the ACI system active and permanent protection of the tank against corrosion using a titanium anode which does not dissolve over time and requires no mainte nance Important Check the correct operation of the safety unit see ins tructions for use from time to time at least once a month Do not worry if ...

Отзывы: