5
5. Horizontal water heaters
Type of water heater
HORIZONTAL HEATER
Nominal capacity
litres
75
100
150
200
Nominal capacity
watts
1200
1800
1800
2100
Heating time (1)
4:30 hr.
3:20 hr.
4:45 hr.
4:55 hr.
Maintaining consumption
kWh per 24 hours at 65˚C (2)
1.01
1.09
1.28
1.70
Cooling constant
Wh per 24 hours / litre / ˚C
0.31
0.29
0.22
0.20
Main dimensions
A
mm
480
600
800
1050
L
mm
691
860
1182
1509
Weight without water
kg
33
39
50
61
(1) As per standard NFC 73 221 (15˚C to 65˚C).
(2) As per French Standard.
Fastening
Horizontal water heaters are fastened with 4 bolts, dia. 10, sealed
into the wall.
A drilling template is supplied with the unit to make it easier to mark
the drilling holes without any need to take measurements.
Horizontal water heaters may be fastened to a wall or the ceiling. In
either case, the connections may be placed to the left or right-hand
side of the heater.
Electrical connections
Horizontal wall-mounted water heaters are designed for a single-
phase 230 VAC power supply. The coupling of multiple voltage hea-
ters is user-modifiable, and may also be set for three-phase 230 V
or 400 V power supplies.
Grounding the metal parts (with the special terminal on the unit) is
compulsory. The section of the line, the omnipole breaking device
and the protection system (fuses or circuit-breakers) shall be selec-
ted in keeping with applicable standards, depending upon the input
intensity, voltage and power.
Note: The heaters must necessarily be connected to a fixed piping system. In prin-
ciple, power will be supplied to the heater at night, manually or automatically with
the help of a clock supplied by the electricity company. In this way, the water is hea-
ted when the reduced off-peak rate is charged for electricity. The unit may be fitted
with a switch for supplying power in the daytime, when the full rate is charged.
Type of water heater
HORIZONTAL HEATER
Capacity
litres
75
100
150
200
Power supply
single multiple multiple multiple
Section
mm
2
1,5
1,5
1,5
2,5
Single-phase 230 V
Intensity
Amp
5,2
7,8
7,8
10,4
Section
mm
2
–
–
1,5
1,5
Three-phase 230 V
Intensity
Amp
–
–
4,5
5,3
Section
mm
2
–
–
2,6
3
Three-phase 400 V
Intensity
Amp
–
–
2,6
3
Hydraulic connections
The connections are marked with blue (cold water) and red (hot
water) discs. Fitting a stop valve on the cold water supply pipe is
compulsory.
Safety rules require that a lead-sealed safety valve calibrated to 7
bar must necessarily be fitted on the cold water supply pipe (for the
guarantee to operate). We recommend the use of diaphragm type
hydraulic safety units bearing the NF mark.
A pressure reducing
valve must be fitted if the supply pressure is greater than 5.5 bar.
Example of installation
Pressurised heater
Type of heater
HORIZONTAL HEATER
Capacity
litres
75
100
150
200
14 x 16
Copper pipe dimensions
mm
12 x 14 or 14 x 16
or
16 x 18
Note : The composite material connecting piece (supplied in a bag) is to be
fitted on the hot water outlet of the heater. It is used to prevent the formation
of a galvanic couple, which can lead to the corrosion of the connection
threads when the heater is connected directly to copper or brass.
;;
@@
;;
yy
;;
;;
@@
@@
;;
;;
yy
yy
;;
;;
@@
@@
;;
;;
yy
yy
Vitreous enamel
with a high quartz
content, resistant to
the most corrosive
water
Imposed current
titanium anode
Thick metal tank
(test pressure
12 bar)
Thimble tube
thermostat
Lacquered white
cladding, curved
square shape
Heating element
made up of an
enclosed resistor on
a steatite support,
accessible without
draining the heater
Mulitpole voltage power
supply connection (except
75 and 100 L models,
single-phase 230 V)
Adjustable thermostat with
built-in thermal safety
device
Hot water outlet pipe
(stainless steel)
Cold water supply
pipe with anti-splash
plug (stainless steel)
Rigid injected
polyurethane foam
insulating material
(0 % CFC)
8971Q008
min. support height 300
(not supplied)
on the floor
on an wall
on the ceiling
L
A
30
120
490
100
505
440
275
530
580
600
440
275
691
480
30
195
254
90
505
cold water
supply R 3/4
hot water
outlet R 3/4
hot water
outlet R 3/4
cold water
supply R 3/4
8978F014
8978F002A
75 l
100-150-200 l
9. Stop valve
28. Cold water supply pipe
29. Pressure reducing valve
30. Safety unit set to 7 bars
a. Cold water inlet including
a non-return valve
b. Connection to the calori-
fier cold water inlet.
c. Stop valve.
d. valve and manual drain.
e. Drain orifice.
54. YA type load break (heal-
th regulations).
57. Hot water outlet
9
29
57
28
b
c
d
e
2 cm
(54)
30
a
8978F001