7. Select Confirm to confirm the setting.
5.11 Monitoring the energy consumption
If your installation is equipped with an energy meter, you can monitor your
energy consumption.
1. Press the key.
2. Select
User settings.
3. Select Energy counter.
The energy consumed since the last energy consumption meter
reset is displayed:
Tab.34
Parameter
Description
CH Energy Consumed
Energy consumed for central heating
DHW energy consumed
Energy consumed for domestic hot water
Cool Energy consumed
Energy consumed for cooling
CH Energy delivered
Thermal energy delivered for central heating
DHW Energy delivered
Thermal energy delivered for domestic hot water
Cool Energy deliver.
Thermal energy delivered for cooling
Total EnergyDeliver.
Total thermal energy delivered
5.12 Starting and stopping the heat pump
5.12.1 Starting the heat pump
1. Switch on the outdoor unit and the indoor unit.
The heat pump will begin an automatic vent programme (which lasts
approx. three minutes), run each time the power is switched on. If
there is a problem, an error message is displayed on the home
screen.
2. If an error message is displayed on the home screen, contact the
installer.
3. Check the hydraulic pressure in the installation indicated on the user
interface.
Important
Recommended hydraulic pressure between 1.5 and 2.0 bar.
5.12.2 Shutting down the heat pump
The heat pump must be shut down in certain situations, for example
during any intervention on the equipment. In other situations, such as an
extended absence period, we recommend that the System holiday mode
operating mode is used in order to benefit from the heat pump anti-
blocking function and to protect the installation from frost.
To shut down the heat pump:
1. Switch off the outdoor unit and the indoor unit.
MW-6000865-02
MW-6000890-1
5 Operation
7763552 - v02 - 29062020
200 ESL HYBRID