COUNTERS, TIME PROG, CLOCK \CIRCA, CIRCB and
DHW menus
Tab.26
Menu
Description
CIRCA
TP.H: Timer programming for heating
06:00 - 23:00 ON
23:00 - 06:00 OFF
TP.C: Timer programming for cooling
14:00 - 23:00 ON
23:00 - 14:00 OFF
CIRCB
TP.H: Timer programming for heating
06:00 - 23:00 ON
23:00 - 06:00 OFF
TP.C: Timer programming for cooling
14:00 - 23:00 ON
23:00 - 14:00 OFF
DHW
Timer programming for domestic hot water
06:00 - 23:00 ON
23:00 - 06:00 OFF
COUNTERS, TIME PROG, CLOCK \CLK menus
Tab.27
CLK parameter
Unit
HMI
HOURS
Can be set from 0 to 23
available
MINUTE
Can be set from 0 to 59
available
DATE
Can be set from 1 to 31
available
MONTH
Can be set from 1 to 12
available
YEAR
Can be set from 2000 to 2100
available
6.3
Setting the parameters
6.3.1
Setting the room temperature set point in comfort mode
Important
The room temperature set point can be managed via the TIME
PROG sub-menu dedicated to timer programming.
Important
To set the room set point temperature in reduced mode, it is
necessary to set the CP080 parameter available in the User
menu.
When the setting is made in a reduced mode range, this setting
shortcut is used only to set the set point temperature in comfort
mode corresponding to the CP081.
1. Access the heating parameters by pressing the key twice.
2. Display the parameters for the required circuit by pressing the or
key.
Fig.33
MW-5000144-3
6 Settings
7613346 - v06 - 02072019
200 ESL HYBRID
39