Product name
200 ESL
Hybrid 8MR-2
+ EFU C 24
200 ESL
Hybrid 11MR-2
+ EFU C 19
200 ESL
Hybrid 16MR-2
+ EFU C 24
T
j
= operation limit temperature
COPd
-
or
%
1.63
1.45
1.54
Operation limit temperature for air-to-water
heat pumps
TOL
°C
-10
-10
-10
Heating water operating limit temperature
WTOL
°C
80
80
80
Electrical power consumption
Off mode
P
OFF
kW
0.009
0.009
0.009
Thermostat-off mode
P
TO
kW
0.049
0.049
0.049
Stand-by
P
SB
kW
0.019
0.025
0.025
Crankcase heater mode
P
CK
kW
0.055
0.055
0.055
Supplementary heater
Psup
kW
5.8
9.0
13.7
Type of energy input
Oil
Oil
Oil
Other specifications
Capacity control
Variable
Variable
Variable
Sound power level, indoors - outdoors
L
WA
dB
48 – 66
47 – 69
47 – 69
Annual energy consumption under average
conditions
Q
HE
kWh
GJ
5859
9
7869
13
11525
21
Annual energy consumption under colder con
ditions
Q
HE
kWh
GJ
6548
6
8009
8
10810
10
Annual energy consumption under warmer
conditions
Q
HE
kWh
GJ
1904
0
2580
0
4120
0
Rated air flow rate, outdoors for air-to-water
heat pumps
—
m
3
/h
3300
6000
6000
Declared load profile
L
L
L
Daily electricity consumption
Q
elec
kWh
4.816
4.816
4.816
Annual electricity consumption
AEC
kWh
968
968
968
Water heating energy efficiency
ƞ
wh
%
106.00
106.00
106.00
Daily fuel consumption
Q
fuel
kWh
0.000
0.000
0.000
Annual fuel consumption
AFC
GJ
0
0
0
(1) The rated heat output
Prated is equal to the design load for heating Pdesignh, and the rated heat output of a supplementary heater
Psup is equal to the supplementary capacity for heating sup(Tj).
(2) If
Cdh is not determined by measurement then the default degradation coefficient is Cdh = 0.9.
See
The back cover for contact details.
3.2.5
Circulating pump
Important
The benchmark for the most efficient circulating pumps is EEI ≤
0.20.
The circulating pump in the indoor module is a variable speed pump. It
adapts its speed to the distribution network.
3 Technical specifications
22
200 ESL HYBRID
7613346 - v06 - 02072019