Dedicated Micros ©2007
1
SD Range
RS
RS
5.16
6.1
Step Connecting a Keyboard
The SD supports Dedicated Micro keyboards DM/KBC1 and DM/KBC2. Connect either of
these keyboards via the KBD connector socket on the rear panel.
Note:
Refer to the Unit Operation section of this manual for further guidance regarding the
supported keyboards.
Step Connecting Dennard 00 & 00 Domes
A Dennard 2040/2060 Dome can be connected via either co-axial telemetry or RS485 twisted pair. If
using co-axial the address switches should be set as:
Blue switch - F
Yellow switch - D
If the dome is being connected using RS485, the dome address should be set according to the
camera number of the SD (1-32).
Pin connections for RS485 connection to a Dennard dome on serial port 3/4 are:
Dome Cable SD Serial Connector
Yellow
1 TX+
Green
9 TX-
Содержание SD Range
Страница 1: ...SD Range Installation and Operation Guide...
Страница 72: ...Dedicated Micros 2007 72 SD Range...
Страница 73: ...Dedicated Micros 2007 73 SD Range...
Страница 74: ...Dedicated Micros 2007 74 SD Range Notes...