5. Technical  description 

 

5.1. Unit  description 

 
The dust extraction unit is designed for the collection of mineral, metal and other dry fine 
and coarse dust in the air.  
 

  mounted on chassis, complete and ready-to-use  

  quick relocation possible 

  galvanized tandem chassis with hit brake, TÜV approved 

  electronic control unit with various special functions 

  robust construction, designed for continuous operation 

  recoverable filter system (automatic cleaning during operation) 

  dust bunker to collect fine and coarse dust 

 HEPA-Filter 

stage 

  high air flow velocity  at the inlet side to prevent deposits in the suction line 

  differential pressure monitoring for filter control 

  Manual speed control 

 

5.2. Options 

 

  Automatic control SRE 

  Dust bunker with fill level monitoring and emptying via suction connection 

 
 

5.3. Filter  system 

 
The collected fine dust is deposited on the filter surface and forms the “filter cake” (coat). 
An automatically working Jet-cleaning system ensures the cleaning of the filters during 
operation. The injection nozzles pull air by a suction effect and jet the coat off the filter, 
working from inside to the outside. The blown off dust is collected in the dust bunker and 
can be removed from there. 
 
 

5.4. Filter  cleaning 

 
The cleaning operates automatically when the compressor and the cleaning are switched 
on. The compressor fills the pressure accumulator, which operates the Jet-cleaning 
system. 
 

The Deduster is provided with an integrated compressor for short term uses. In 
case of long term uses, it is essential to use the external compressed air supply! 
 

 

Содержание ME 12

Страница 1: ...Original instruction manual Mobile Deduster ME 12 Manufacturer deconta GmbH Im Geer 20 46419 Isselburg Description Type No Mobile Deduster ME 12 Type 94 565 Serial No ...

Страница 2: ...ance data 7 4 3 Filter data 1 Filter stage regenerative Filter 7 4 4 Filter data 2 Filter stage HEPA Filter 8 4 5 Requirement for towing vehicle 8 5 Technical description 9 5 1 Unit description 9 5 2 Options 9 5 3 Filter system 9 5 4 Filter cleaning 9 6 Initial operation 10 6 1 Option automatic control SRE 11 6 2 Option Dust bunker with filling level control and emptying via suction port 13 7 Main...

Страница 3: ... work including removal and replacement of the filters may only be carried out by authorized persons wearing suitable protective clothing The device must be completely disconnected from the power supply during all repairs and maintenance work The safety and protective systems must be maintained and functioning correctly Safety instructions affixed to the unit must be maintained in a legible condit...

Страница 4: ...esult in death or serious injury Do not damage the mains cable e g by vehicle overrun tearing squeezing Regularly check the mains cable for damage Have defective mains cable replaced before use by the deconta service or a qualified electrician CAUTION Damage due to unsuitable mains voltage The device can be damaged if it is connected to an unsuitable mains voltage Check whether the voltage indicat...

Страница 5: ...the trailer ball of towing vehicle Pull stabilization handle Pos 1 upwards Put opened coupling Pos 2 coupling handle pulled upwards by winding down of support wheel on the trailer ball of the towing vehicle Release coupling handle handle slides back independently into original position Use our hand to press down handle locking and securing is done automatically Press stabilisation handle downwards...

Страница 6: ...it may only be parked in areas inaccessible for unauthorized persons 3 Volume of delivery Regardless if the unit is purchased or rented unless no other agreements have been made the volume of delivery of the Mobile Deduster consists of Unit ME 12 Instruction manual Stoppers Return delivery after ending of rental period For the protection of our clients and in accordance with the rules for hazmat t...

Страница 7: ... ca 2010 mm Weight ca 1400 Kg 4 2 Performance data Exhaust air volume up to 12000 m h Suction speed up to 25 m s Bunkervolumen ca 0 5 m Shock valve G1 12 pcs Control electric 12 channels Dedusting continuously Operating pressure 4 5bar 4 3 Filter data 1 Filter stage regenerative Filter Filter material Polyester needle pleated Filter area ca 100m Quantity filters 24 pcs Filter resistance 4300 Pa Cl...

Страница 8: ... class H13 pursuant EN 1822 Degree of separation 99 95 leak tested in MPPS Most Penetrated Particle Size Temperature humidity 110 C 100 RF relative humidity Filter dimensions in mm 610 x 910 x 292 Handle protection Expanded metal double sided 4 5 Requirement for towing vehicle Ball head coupling Permissible drawbar load 75 kg Ball head 94 20 EG A 50 with min diameter 49 mm Control device not rotat...

Страница 9: ...ilter control Manual speed control 5 2 Options Automatic control SRE Dust bunker with fill level monitoring and emptying via suction connection 5 3 Filter system The collected fine dust is deposited on the filter surface and forms the filter cake coat An automatically working Jet cleaning system ensures the cleaning of the filters during operation The injection nozzles pull air by a suction effect...

Страница 10: ... to Deduster 400V 32A 3N PE Switch on Main switch make sure the Lamp Mains Ok lights up Switch on Fan Fan active lights up and wait until the motor is running Switch on Cleaning Cleaning active lights up When an external Compressor is connected the lamp Compressed air external lights up The unit is operating The desired performance can be set by turning the rotary knob Fan control Main switch Moun...

Страница 11: ...tive pressure in the working area Specify the measuring point in the working area and connect to the connection negative pressure with PE hose 8 x 1 Determine the measuring point in the clean area adjoining rooms an connect to the connection atmosphere with PE hose 8 x 1 Connection external Compressor Min 5 bar max 10 bar Connection negative pressure Connection atmosphere ...

Страница 12: ...h the keys and display set value in automatic mode By comparing the entered set point value with the permanently measured current actual value measured negative pressure the speed of the fan is automatically adapted that is the fan moves automatically up and down Important In the event of power failure the control saves the last set values restarts automatically after damage elimination and restor...

Страница 13: ...signal horn can be connected to this alarm socket For emptying the bunker there are 2 suction connections on the unit Switch off Fan and Cleaning function of the mobile dust extractor Connect the suitable vacuum cleaner to the suction connection Open shut off valve The Bunker can now be vacuumed Please note After emptying the shut off valve must be closed again Dust bunker Fill level monitoring Su...

Страница 14: ...r and checked by a qualified technician The test result shall be presented on request 7 1 Details on filter change The frequency of the filter change depends on the degree of contamination of the filters As the filter occupancy is increased contamination of the filters the air performance decreases For filter monitoring during operation there are two manometers installed on the device We recommend...

Страница 15: ...tive compononents Have unit repaired by deconta or a workshop authorized by deconta Cleaning of filter does not work Plug of solenoid valve may be loose Insert plug one more time Compressor does not run Compressor is not switched on Remove right front panel und switch on compressor Compressor does not run Plug of compressor came off Remove right front panel and insert plug again Caution Work on th...

Страница 16: ...65 complies with all applicable regulations of the above mentioned directive and the other applicable directives hereafter including the amendments applicable at the time of the declaration The following other EU directives were applied EMC directive 2004 108 EC The following harmonized standards were applied EN 60204 1 2006 AC 2010 EN 60335 2 69 2012 The following national or international standa...

Отзывы: