Manual operation:
In manual operation, the „+“ and „-“ keys are used to set the fan performance. The
display show the performance value in „%“ and the measured negative pressure.
Automatic operation:
In automatic mode, the set point in Pascal for the negative pressure is preset with the
keys „+“ and „-„ (display set value in automatic mode). By comparing the entered set
point value with the permanently measured current actual value (measured negative
pressure), the speed of the fan is automatically adapted, that is, the fan moves
automatically „up“ and „down“.
Important:
In the event of power failure, the control saves the last set values, restarts automatically
after damage elimination and restores the saved data.
Set value in automatic operation
Operating mode (AUTO or MANUAL)
Measured negative pressure
Fan performance in %