Operating Instructions for the Dean Stoves 105SE Inset 

(

105IS issue1st October 2016)

 

All stoves meet the essential type test requirement  

BS EN13229:2001 + A1:2003 +A2:2004, CE marked 

The 105Se inset is Ecodesign ready and satisfies all the stringent 

emission requirements.  

 

The Clean Air Act 1993 and Smoke Control Areas

 

  
Under the Clean Air Act local authorities may declare the whole or part of the district of the 
authority to be a smoke control area. It is an offence to emit smoke from a chimney of a 
building, from a furnace or from any fixed boiler if located in a designated smoke control area. 
It is also an offence to acquire an "unauthorised fuel" for use within a smoke control area 
unless it is used in an "exempt" appliance ("exempted" from the controls which generally apply 
in the smoke control area). 
  
The Secretary of State for Environment, Food and Rural Affairs has powers under the Act to 
authorise smokeless fuels or exempt appliances for use in smoke control areas in England. In 
Scotland and Wales this power rests with Ministers in the devolved administrations for those 
countries. Separate legislation, the Clean Air (Northern Ireland) Order 1981, applies in 
Northern Ireland. Therefore it is a requirement that fuels burnt or obtained for use in smoke 
control areas have been "authorised" in Regulations and that appliances used to burn solid 
fuel in those areas (other than "authorised" fuels) have been exempted by an Order made and 
signed by the Secretary of State or Minister in the devolved administrations. 
  
The Dean Stoves, 105Se inset has been recommended as suitable for use in smoke control 
areas when burning wood logs. 
 
To use the 105Se inset in smoke controlled areas the smoke control kit must be fitted to the 
stove. 
  
Further information on the requirements of the Clean Air Act can be found here: 
http://smokecontrol.defra.gov.uk/  
Your local authority is responsible for implementing the Clean Air Act 1993 including 
designation and supervision of smoke control areas and you can contact them for details of 
Clean Air Act requirements 

 
Important  

You will find a rectangular shaped plate with slotted holes in it, situated on the top of the main 
grate. This grate is design to retain the ash when burning wood only and must NOT be used 
when burning solid fuel (smokeless fuel or similar) or a mixture of wood and solid fuel. This 
plate can be lifted out prior to lighting the fire, if required. Although the stove will burn wood 
straight on the solid fuel grate, the rectangular shaped plate retains the ash and helps to give a 
slower and hotter burn. By using the suppled tool/poker the ash can be pushed backwards and 
forwards which will help it drop through to the ash pan. Always leave a small layer of ash on 
the plate. 

Содержание 105SE

Страница 1: ...rthern Ireland Therefore it is a requirement that fuels burnt or obtained for use in smoke control areas have been authorised in Regulations and that appliances used to burn solid fuel in those areas other than authorised fuels have been exempted by an Order made and signed by the Secretary of State or Minister in the devolved administrations The Dean Stoves 105Se inset has been recommended as sui...

Страница 2: ...nts are in place to cover the requirements of such appliances Extractor Fans Do not use an extractor fan in the same room when operating a stove Wood Suitable fuels Dry wood 18 moisture content or below must be used or the stove and flue will tar up and the door won t stay clean Wood is best seasoned by splitting it into a log and dried for 2 years in a covered area allowing air to pass through Wh...

Страница 3: ...air flow The secondary air wash control is indicated with double ring turned into the control knob This controls the preheated air wash system Once the fire in the stove is established this is the control that should be used to control the fire when burning wood The secondary control works as follows Pull out fully for maximum air flow into the fire and fully in for minimum airflow to the fire Onc...

Страница 4: ...recommended that you do not leave the appliance unattended until it is certain that the logs are burning well with a sustained flame Do not load the fuel above the log retainer Please note If there is insufficient burning material in the fire bed to light a new fuel charge excessive smoke emission can occur Refuelling must be carried out onto a sufficient quantity of glowing embers and ash that th...

Страница 5: ...ould burn well for about 1 5 2 hours before the need to riddle the fire In the summer or when the stove is not being used for a long period of time clear all the ash out and leave primary and secondary air vents open to prevent condensation Please Note When lighting the stove for the first time the paint on the stove will cure and give off a metallic smell It is advisable to ventilate the room ie ...

Страница 6: ... Check there is no blockage or restriction in the flue 2 Check the external air vent is not blocked 3 Check the baffle plate has not dislodged itself from the stove 4 Call an engineer If the stove does not perform properly this is could be due to unseasoned wet wood or too much ash in the firebox In the case of the stove malfunctioning shut all vents open the windows and let the residual fuel in s...

Страница 7: ... supplied with an extension frame This frame can be used when the fireplace aperture cannot be covered by the stove alone The frame sits behind the stove front before the stove is secured into the fire place aperture Securing the stove The stove must be securely fixed to the hearth via the securing hole in the base of the stove To access this securing hole you will need to remove the great A 120mm...

Страница 8: ...thick 1 2 The hearth must extend at least 225mm in front of the firebox and 150mm to the sides It is recommended that a larger hearth size is fitted if possible The stove is designed to fit into a non combustible chimney opening If a combustible mantel piece is to be fitted to the fireplace it must be at least 400mm above the top of the stove and 200mm at the sides these are minimum distances The ...

Страница 9: ...tted for all stoves with a kw rating of over 5kw Very air tight properties designed with air permeability less than or equal to 5 0 m3 h m2 per hour an air vent will need to be fitted for all kilowatts It must be considered when fitting air vents that it is taken into account any other appliance fitted within the room Please Note Extractor fans when operating in the same room or space as the appli...

Страница 10: ...ides of the stove 200mm Stove Performance 105Se inset Wood burning 5kW nominal 77 0 Net Efficiency Solid Fuel Maxibite 5kW nominal 76 9 Net Efficiency All stoves are tested to nominal outputs and will well exceed these kilowatt ratings EC Declaration Of Conformity The Undersigned representing the following Manufacturer Dean Forge Ltd Dean Prior Buckfastleigh Devon TQ11 0LS Herewith declare that th...

Страница 11: ...rovisions to which the product conforms Product Room heater fired by solid fuel as covered under the scope of the standards listed Intended use Space heating in residential building Characteristic Performance Report Fire Safety Satisfies Emission of combustible products and Thermal output Efficiency 105Se Inset STDF105I Co 13 0 Wood 0 31 Maxibrite 0 31 5 0Kw 77 Wood 5Kw 76 9 Maxibrite 6931 2 Relea...

Страница 12: ...mission Delegated Regulation 105Se inset Nominal Heat Output to Room KW Nominal Heat Output to Water KW Dean Stoves EU 2015 1187 Seasonal Space Efficiency Net Efficiency Supplier s Name Model Energy Efficiency Class Energy Labelling of Local Space Heaters ...

Страница 13: ...your supplier installer for any relevant guarantees applicable to the installation Dean Forge Fabrication Ltd will not be held liable for any consequential or incidental loss damage or injury however caused Claims under this guarantee should be first made through your retailer This guarantee is only applicable in the UK Nothing in this guarantee shall affect your statutory rights Exclusions The fo...

Страница 14: ...14 ...

Страница 15: ...abrication Ltd Dean Prior Buckfastleigh Devon TQ11 0LS PRODUCT REGISTRATION Name Address Phone Number Suppliers Details Name Address Phone Number Installers Details Name Address Phone Number HETAS Registration Number ...

Страница 16: ...16 ...

Отзывы: