4.23. UNIT’S TAIP REFERENCE
4.23.25
(XACT) Communication Test
Qualifiers
:
S
,
R
Use this message to generate an event code to a
Destination Address
(DA). This message is used to test the communication with a given
destination(s) without requiring for an specific event to occur. It
is also a method for testing a DA definition and testing the remote
host identification process of an
EV
message. The message has the
following format:
ABB
Chars
Item
Format
Value
Meaning
1
Destination
Address
A
0-9
Destination Address to which
generate the “fake” event.
2
event code
BB
00-49
Event code to report.
161