4.23. UNIT’S TAIP REFERENCE
4.23.22
(XAAP) Auto Power-ON, periodic
Qualifiers
:
S
,
Q
,
R
This message is used to configure a periodic, automatic power-ON.
The period can be set as a daily turn-on with a time-of-day parameter
or it can be set as a time interval defined with hours, minutes and sec-
onds. For a daily configuration, the date and time information from
the unit is taken as the GMT time. Daily and time-based configura-
tions are exclusive. A non-periodic date-based automatic power-ON
can also be set with the
XATP
message. This configuration combined
with a sleep timer enable the unit to increase battery-duration on
no-reporting periods. See the
XAPM
message. The message has the
following format:
ABBCCDD
Chars
Item
Format
Value
Meaning
1
type
A
T or D
Type of periodic power-ON:
D:
Daily. BBCCDD specify the
time-of-day.
T:
Time interval specified by
BBCCDD.
U:
Disable periodic power-ON.
2
hours
BB
00-99
Hours.
2
minutes
CC
00-99
Minutes.
2
seconds
DD
00-99
Seconds.
For example, to have the unit turn on every hour:
>
SXAAPT010000
<
To have the unit turn on every day at 9 AM:
>
SXAAPD090000
<
To deactivate the automatic power-ON:
>
SXAAPU
<
.
To achieve a periodic turn-ON/OFF, an Sleep Timer has to be
set too. See the
XAPM
message.
Warning:
See also the
XATP
for an automatic power-ON on a set Date/Time.