The 480, 481 and 482 DriveRack™ units offer you the option of changing the input gain level settings. There are 3 hard-
ware configurable gain settings. They are: +14 dBu, +22 dBu and +30 dBu. For these cases, use the following pro-
cedure to change the gain level settings. Please be advised however, that once the gain level has been changed from
the factory settings, the output meters will no longer be calibrated correctly.
To change the gain level, move the jumpers to the pins that are marked with the desired gain setting
1) First, ground yourself prior to opening the DriveRack™ chassis to prevent ESD damage.
2) Open the chassis by removing five screws on each side of the chassis and the top two center screws on the rear panel,
as well as the top center allen screw located on the front panel
3) Locate the jumper block shown in the illustration below:
4) Set the jumpers to the desired input and output gain settings. Note that to change settings on inputs 3 and 4 and out-
puts 5-8 of the 480 and 482, the top board must be removed.
5) Once the desired settings have been made, replace the chassis lid.
481 Top Board
Input Jumpers
Output Jumpers
+22dBu
Ch1
+30dBu
+30dBu
Ch1
Ch2
Ch1
Ch2
+14dBu
Ch2
+14dBu
+22dBu
+22dBu
Ch3
+30dBu
+30dBu
Ch3
Ch4
Ch3
Ch4
+14dBu
Ch4
+14dBu
+22dBu
+14dBu
+22dBu
+30dBu
+14dBu
+22dBu
+30dBu
+14dBu
+22dBu
+30dBu
+14dBu
+22dBu
+30dBu
+14dBu
+22dBu
+30dBu
+14dBu
+22dBu
+30dBu
+14dBu
+22dBu
+30dBu
+14dBu
+22dBu
+30dBu
480 and 482 Top Board
Input Jumpers
Output Jumpers
+22dBu
Ch1
Ch1
Ch2
Ch3
Ch4
+30dBu
+14dBu
+14dBu
+22dBu
+30dBu
+14dBu
+22dBu
+30dBu
+14dBu
+22dBu
+30dBu
+14dBu
+22dBu
+30dBu
+22dBu
Ch2
NOTE: Inputs 3 and 4 are located directly beneath inputs 1 and 2 on the underside of the board.
Outputs 5-8 are located directly beneath Outputs 1-4 on the underside of the board.
+30dBu
+14dBu
CAUTION: These servicing instructions are for use by qualified service
personnel only. To reduce the risk of electric shock, do not perform any
servicing other than that contained in the operating instructions unless you
are qualified to do so. Refer all servicing to qualified service personnel.
Disconnect mains power before servicing.
A.8 Gain Level Jumpers
Appendix A
DriveRack
™
DriveRack™ User Manual
105
Содержание DriveRack 480
Страница 1: ...User Manual CompleteEqualization LoudspeakerManagementSystem 480 481 482 480R...
Страница 6: ...INTRO CUSTOMER SERVICE INFO Defining the DriveRack WARRANTY INFO INTRODUCTION DriveRack...
Страница 11: ...Getting Started Section 1 DriveRack...
Страница 19: ...EDITING FUNCTIONS Editing Functions Section 2 DriveRack...
Страница 23: ...2 5 Navigating the EQ Sections Editing Functions Section 2 DriveRack 13 DriveRack User Manual...
Страница 24: ...Editing Functions 14 Section 2 DriveRack 2 6 Navigating the XOVER DriveRack User Manual...
Страница 25: ...2 7 Navigating the RTA Editing Functions Section 2 DriveRack 15 DriveRack User Manual...
Страница 26: ...Editing Functions 16 Section 2 DriveRack 2 8 Navigating the Delay DriveRack User Manual...
Страница 27: ...2 9 Navigating the Dynamics Section Editing Functions Section 2 DriveRack 17 DriveRack User Manual...
Страница 28: ...Editing Functions 18 Section 2 DriveRack 2 10 Navigating the Other Section DriveRack User Manual...
Страница 29: ...2 11 Navigating the Utility Section Editing Functions Section 2 DriveRack 19 DriveRack User Manual...
Страница 30: ...CONFIGURATION FUNCTIONS SOFTWARE Section 3 DriveRack...
Страница 40: ...DETAILED PARAMETERS PARAMETERS Section 4 DriveRack...
Страница 52: ...STORING PROGRAM CHANGES Storing Programs Section 5 DriveRack...
Страница 56: ...UTILITIES SECTION Utilities Section 6 DriveRack...
Страница 66: ...NETWORK FUNCTIONS Network Functions DriveRack...
Страница 82: ...480R Remote Controller Section 8 DriveRack...
Страница 90: ...APPLICATION GUIDE Section 9 DriveRack...
Страница 97: ...Appendix DriveRack...
Страница 114: ...DriveRack User Manual 106 Appendix A DriveRack A 9 Input and Output Diagrams...