Step 5.
Record inspection data:
Record the inspection date and results in the
Inspection and
Maintenance Log
(see Section 9).
Step 6.
Inspect the Stitched Impact Indicator:
The stitched impact indicator is a section of webbing
that is lapped back on itself and secured with a speci
fi
c stitch pattern holding the lap (see
Figure 16). The stitch pattern is designed to release when the harness arrests a fall or has been
subjected to an equivalent force If the impact indicator has been activated the harness must be
removed from service and destroyed.
Step 7.
Inspect Suspension Trauma Straps:
Check the trauma strap pouches for damage and secure
connection to the harness. Unzip the trauma strap pouch on each hip of the harness and inspect
suspension trauma straps. Webbing and pouch material must be free of frayed, cut, or broken
fi
bers. Check for tears, abrasions, mold, burns, discoloration, or knots. Verify that one pouch is
marked
‘Hook’
and the other marked
‘loop’
.
IMPORTANT:
If inspection reveals a defective condition, remove the unit from service immediately and
destroy it.
NOTE:
Only DBI-SALA or parties authorized in writing may make repairs to this equipment.
Figure 16- Stitched Impact Indicator
A. Stitched Impact Indicator
A
A
6.0 MAINTENANCE, SERVICING, AND STORAGE
6.1 WASHING
INSTRUCTIONS:
Washing procedures for the ExoFit NEX™ Full Body Harness are as follows:
Step 1.
Spot clean the ExoFit NEX™ full body harness with water and a mild soap solution.
IMPORTANT:
Use a bleach-free detergent when washing the harness and pads. Fabric softener or dryer
sheets SHOULD NOT be used when laundering and drying the harness and pads.
Step 2.
Water temperature for wash and rinse must not exceed 160° F (70° C).
Step 3.
The harness and pads may be air dried or tumble dried on low heat not exceeding 200° F (90° C).
NOTE:
More information on cleaning is available from Capital Safety. If you have questions concerning the
condition of your harness, or have any doubt about putting it into service, contact Capital Safety.
6.2 ADDITIONAL MAINTENANCE AND SERVICING:
Additional maintenance and servicing procedures must
be completed by a factory authorized service center. Authorization must be in writing. Do not attempt to
disassemble the unit.
6.3 STORAGE:
Store the ExoFit NEX™ Full Body Harness in a cool, dry, clean environment out of direct sunlight.
Avoid areas where chemical vapors may exist. Thoroughly inspect the full body harness after extended
storage.