4
NOTE
Maximum heating output is based on average
2
irradiation levels of 6000W/m /day prevailing in
September- March and minimum Heating output is
2
basedon average irradiation levels of 4000W/m /day
prevailing in June/July and are for indicative purposes
only.
A
D
E
B
3. WARNING AND SYMBOLS
The installation of the solar system must be in accordance with
the relevant requirements of the local authority building
regulations as well as regulations for the prevention of
accidents when carrying out works such as solar installation. It
is necessary to do so in a safe and professional manner, taking
due care of any aspects of the works that could result in injuries
to the person, buildings as well as general public.
Work should be preceded by a risk assessment covering all
aspects of health and safety risks, or training requirements
that are reasonably foreseen.
These instructions describe mounting and installation of
thermosiphon solar water heaters. All installations must be
done by qualified people.
Installers must adhere to the valid work protection regulations,
in particular when working on the roof. Anti-fall protection
must be employed whenever there is a risk of falling.
To avoid the risk of being burned or scalded by hot
components, Installation and replacement of collectors or
parts should be done on cloudy days. Installation work on
sunny days should be carried out only in the morning or
evening or with the collector covered.
To avoid the risk of being burned or scalded by hot solar fluid
or components, fill and flush the solar system when the
collectors are cold. The collectors should be covered while
doing so.