The strips can be used to fit the system to the battens of the roof to provide additional
support. Please note that longitudinal channel should coincide with or be as closely
located to the rafters of the roof structure as possible. The strip fastening method is
depicted below in section view. Use all six fastening points to support the structure.
13
After the bracket system is securely fastened to the roof, the tank can be re-fitted. Use the
straight compression couplers to connect collectors in parallel for double panel systems
and re-fit the collectors between the angled sections and fasten with screws.
Step 10
Connect piping as shown on
Fig 1
. Use appropriate roof seals supplied to seal off any
pipe entry points into the roof.
Step 11
Apply pipe insulation to all exposed pipes.