Frequently the cooled air flowing through raised floor panels does not 

reach servers and IT equipment at top of the server cabinets. Hardware is not 
cooled properly, overheats and can fail. High-plume airflow and high cold air 
pressure can resolve these problems. Increasing static air pressure via the CRAC 
units only increases energy costs and rarely gives the desired effect - pushing 
cold air to the top of the server racks. The result of using inefficient perforated 
floor tiles is enormous power consumption, ever increasing energy costs and 
hotspots which shorten the life of data centre hardware. There is another solu-
tion that is cost effective and efficient - CoolControl Tiles are passive perforated 
floor panels that have 65% airflow throughput ensuring cooler hardware and 
lower energy costs.

Patented fin design with high airflow for optimum 
cooling and efficiency 

 

Conventional perforated raised 

floor panels achieve airflow rates of 
20-30%. The CoolControl Tile achieves 
65% airflow as well as directing con-
ditioned air to the upper most levels of 
server racks. The higher the flow rate, 
the higher the volume of cold air that 
reaches your rack equipment. It is 
critical that the perforated raised floor 
tiles provide enough cold air via high-
plume stratification. Only then can the cold air reach the top of the cabinets to 
cool the upper most hardware. Sufficient cool air is the primary factor in prevent-
ing system failures and downtime created by overheating and hotspots. Cool-
Control Tile‘s Hi-Plume Stratification Fin scoops air to the upper most servers, 
while ensuring middle and lower servers also receive required cooling capacity. 
Through this unique design server temperatures can be decreased by 3-8°C while 
simultaneously lowering energy consumption. In choosing the most effective 
perforated floor tiles, remember the following: The higher the airflow rate and the 
higher the airflow stratification the lower the required cooling capacity resulting 
in energy and cost savings. 

CoolControl Tiles 

– Incorporating Triad Technology 

Cooler server temperatures with lower  
energy consumption

Rack airflow  
with conventional 
floor tiles

Rack airflow  
with CoolControl 
Tiles 

CoolControl Tiles Highlights

•   Optimised hi-plume stratification fins 

•   Patent protected Lift-n-Lock handles provide  
  safe lifting and placement

•   Airflow rate up to 65 percent 

•   Protects cabinet hardware against overheating  
  and downtime

•   Optional dampers to reduce airflow

•   Significant reduction of energy consumption  
  and costs

•   Ultimate load of up to 1360kg

Please click on the graphic for a demo.