Страница 1: ...1...

Страница 2: ...yourself In case of you use LPG gas do not mount your water heater in places below the ground level Check whether your device conforms to the gas type you will use or not Provide flexible connections...

Страница 3: ...er will be prevented The flame instability is prevented and the water is cooled after the flame is off with the features of blowing inside the water heater before the ignition air fan blows air for 2...

Страница 4: ...4 warnings In case of fault condition it gives information about fault reason with fault code 3 THE CONFIGURATION OF WATER HEATER...

Страница 5: ...5...

Страница 6: ...6 The control panel is not integrated on the water heater and provides remote control opportunity Maximum of three control panels can be used in the same water heater 3 1 Control Panel Configuration...

Страница 7: ...45 mm Weight 23 5 Kg The mounting of the water heater should be made by an authorized person Please contact with our authorized sales agencies or companies which are authorized by the authorized gas a...

Страница 8: ...ter or the rain water to the heater the part of the waste gas pipe remaining outside the environment should be placed as to make a horizontal angle of 3 degrees Squall to waste gas pipe may cause devi...

Страница 9: ...riate diameter from the bottom and top of the device according to the measurements of the water heater mounting holes Fix the appropriate diameter fixing plug to the holes Drill 135 mm waste gas pipe...

Страница 10: ...ntrol base with screws from the mounting holes on the wall in the desired area Connect the connector to the cable that will provide the connection between the water heater and the control panel and pl...

Страница 11: ...l be connected to water inlet of the water heater Installation of silt trap after valve is recommended for water installations which has probability of entering dirt inside of water heater from waters...

Страница 12: ...qualified personnel with suitable cable section There must be a fuse with a suitable specification and6 amperes value that can completely cut off the electricity of the device The fuse should be clos...

Страница 13: ...e water heater should be done by the Authorized Service For this please contact the authorized service in your region Conrol if the gas electricity and water properties are same values specified in th...

Страница 14: ...splay By pressing button it can be exit by confirming matching Even not pressed button matching will automatically confirmed after a while Repeat the above steps for more remote control panel matching...

Страница 15: ...t standby mode water temperature can be change with and buttons between 35 o C and 65 o C According to temperature valueeach pressing incerasing value will show dfferences Temperature Range Increasing...

Страница 16: ...case completely empty the water inside the water heater against the risk of freezing as the frost protection will not work To operate the water heater again follow the steps in 6 1 2 Make sure the use...

Страница 17: ...for not blocking of heat exchanger because of specification of water such as hard water Blocking of water heater exchanger is out of warranty If your pressure of installation is high because of water...

Страница 18: ...s pipe during using and after a short time of using against skin burns In case of failure of your water heater do not panic and stop using the heater Disconnect the gas and the electricity Consult the...

Страница 19: ...cturing defect When you have a problem during using please contact our after sales service department The unauthorized repair and the maintenance of the device will void its warranty cover Our company...

Страница 20: ...ode 11 12 13 Water Temperature is over 95 o C Control Water Flow 32 Blocking of pipe duct Remove blocking and dirts at pipe duct 40 Fan operation error Call authorised service 50 Outlet water is 85 o...

Страница 21: ...Authorised Services Water valve is not turn on enough Turn On water valve completely Insufficient fresh air Control device pipe Windy weather Do not use it until the wind passes Freezing water Use ag...