background image

17

 

anything before the gas leaves out completely. Do not forget that    any flame or 

a spark that may occur in such a case, will lead to fire or explosion.  

  Pipe  and  connection  pipes  must  be  controlled  regularly.  If  it  is  suspected  that 

there is gas leakage because of pipes apply to necessary gas distributor  

  If  it  is  suspected  that  there  is  leakage  except  from  pipe  and  connection  pipes, 

must be consulted to our service department.  

  Old  or  cracked  pipes  must  be  changed  urgently  by  controlling  gas  pipes 

regularly. 

  If  it  is  heard  abnormal  combustion  voice  from  water  heater,  stop  using  water 

heater then consult to service department.  

  In  the  first  contact  with  hot  water,  check  the  temperature  of  the  water  before 

touching the body. 

 

  Check the newly mounted water heater carefully and make sure that it operates 

correctly before using.  

  Do not drink the water passing inside the water heater  

  Take precautions for not blocking of heat exchanger because of specification of 

water  such  as  (hard  water).  Blocking  of  water  heater  exchanger  is  out  of 

warranty.  

  If  your  pressure  of  installation  is  high,  because  of  water  quantity  passing  from 

water heater will be more, noise can occur at device and your installation can be 

damage. In such cases, absolutely you need to install pressure reduce valve to 

device inlet.  

  If  necessary  precautions  are  not  taken,  situations  which  ambient  temperature 

deduct under the 0 degree, water inside heater can give damage to your heater 

by freezing. It is possible to prevent this situation by doing following information.  

  With freezing prevention of your water even device inside temperature reduce 

under  “0”  degree,  it  can  be  prevented  freezing  of  water  which  is  inside  the 

device.  When  ambient  temperature  decreases  specific  value,  your  water 

heater  will  heat  water  by  automatically  operating  in  short  period  and  will 

prevent  freezing.  In  the  meantime,  “AF”  warning  will  be  seen.  For  the 

operation of this system, gas and electricity must not be cut off and the light of 

6.4. For The Safe Use

 

Содержание UKDAX-20VT

Страница 1: ...1...

Страница 2: ...yourself In case of you use LPG gas do not mount your water heater in places below the ground level Check whether your device conforms to the gas type you will use or not Provide flexible connections...

Страница 3: ...er will be prevented The flame instability is prevented and the water is cooled after the flame is off with the features of blowing inside the water heater before the ignition air fan blows air for 2...

Страница 4: ...4 warnings In case of fault condition it gives information about fault reason with fault code 3 THE CONFIGURATION OF WATER HEATER...

Страница 5: ...5...

Страница 6: ...6 The control panel is not integrated on the water heater and provides remote control opportunity Maximum of three control panels can be used in the same water heater 3 1 Control Panel Configuration...

Страница 7: ...45 mm Weight 23 5 Kg The mounting of the water heater should be made by an authorized person Please contact with our authorized sales agencies or companies which are authorized by the authorized gas a...

Страница 8: ...ter or the rain water to the heater the part of the waste gas pipe remaining outside the environment should be placed as to make a horizontal angle of 3 degrees Squall to waste gas pipe may cause devi...

Страница 9: ...riate diameter from the bottom and top of the device according to the measurements of the water heater mounting holes Fix the appropriate diameter fixing plug to the holes Drill 135 mm waste gas pipe...

Страница 10: ...ntrol base with screws from the mounting holes on the wall in the desired area Connect the connector to the cable that will provide the connection between the water heater and the control panel and pl...

Страница 11: ...l be connected to water inlet of the water heater Installation of silt trap after valve is recommended for water installations which has probability of entering dirt inside of water heater from waters...

Страница 12: ...qualified personnel with suitable cable section There must be a fuse with a suitable specification and6 amperes value that can completely cut off the electricity of the device The fuse should be clos...

Страница 13: ...e water heater should be done by the Authorized Service For this please contact the authorized service in your region Conrol if the gas electricity and water properties are same values specified in th...

Страница 14: ...splay By pressing button it can be exit by confirming matching Even not pressed button matching will automatically confirmed after a while Repeat the above steps for more remote control panel matching...

Страница 15: ...t standby mode water temperature can be change with and buttons between 35 o C and 65 o C According to temperature valueeach pressing incerasing value will show dfferences Temperature Range Increasing...

Страница 16: ...case completely empty the water inside the water heater against the risk of freezing as the frost protection will not work To operate the water heater again follow the steps in 6 1 2 Make sure the use...

Страница 17: ...for not blocking of heat exchanger because of specification of water such as hard water Blocking of water heater exchanger is out of warranty If your pressure of installation is high because of water...

Страница 18: ...s pipe during using and after a short time of using against skin burns In case of failure of your water heater do not panic and stop using the heater Disconnect the gas and the electricity Consult the...

Страница 19: ...cturing defect When you have a problem during using please contact our after sales service department The unauthorized repair and the maintenance of the device will void its warranty cover Our company...

Страница 20: ...ode 11 12 13 Water Temperature is over 95 o C Control Water Flow 32 Blocking of pipe duct Remove blocking and dirts at pipe duct 40 Fan operation error Call authorised service 50 Outlet water is 85 o...

Страница 21: ...Authorised Services Water valve is not turn on enough Turn On water valve completely Insufficient fresh air Control device pipe Windy weather Do not use it until the wind passes Freezing water Use ag...

Страница 22: ...imited irketi Nam k Kemal Mah Marmara Cad No 74 mraniye stanbul Tel 90 216 369 85 36 37 Fax 90 216 385 95 45 E Mail info daxom com Merkez Servis Nam k Kemal Mah Marmara Cad No 74 mraniye stanbul Tel 9...

Отзывы: