WSSFC-CAP10-MN-EN-01

FEB-2022

SKU

WSSFC-G4F-NH3

HW Ver.

1.1

FW Ver.

1.0

Item Code

WSSFC-CAP10-8-1500

SIGFOX HIGH PRECISION CAPACITANCE FUEL LEVEL SENSOR FOR DIESEL OIL, VEGETABLE OIL,
LUBRICANT, 1500MM, FIELD CUTTABLE, INTERNAL ANTENNA, TYPE AA BATTERY 1.5VDC, IP67,
RC1 ZONE

 

WSSFC-CAP10-9-1500

SIGFOX HIGH PRECISION CAPACITANCE FUEL LEVEL SENSOR FOR DIESEL OIL, VEGETABLE OIL,
LUBRICANT, 1500MM, FIELD CUTTABLE, INTERNAL ANTENNA, TYPE AA BATTERY 1.5VDC, IP67,
RC2-RC4 ZONES

 

CAP10PROEXT0700

CAP10 PROBE EXTENSION LENGTH 700 MM

 

CAP10PROEXT1000

CAP10 PROBE EXTENSION LENGTH 1000 MM

 

CAP10PROEXT1500

CAP10 PROBE EXTENSION LENGTH 1500 MM

USER GUIDE FOR SIGFOX-READY
PRECISION FUEL LEVEL SENSOR
WSSFC-CAP10

This document is applied for the following products

0. Configuration Check List

0.1 Configuration Sigfox Sensor

Содержание WSSFC-G4F-NH3

Страница 1: ...PRECISION CAPACITANCE FUEL LEVEL SENSOR FOR DIESEL OIL VEGETABLE OIL LUBRICANT 1500MM FIELD CUTTABLE INTERNAL ANTENNA TYPE AA BATTERY 1 5VDC IP67 RC2 RC4 ZONES CAP10PROEXT0700 CAP10 PROBE EXTENSION LE...

Страница 2: ...s Configure parameters like cycle send data alarm a b Refer to the configuration section 6 STEP 4 Add device to Backend Sigfox refer to section 6 2 for details STEP 5 Installation refer to section 9 f...

Страница 3: ...ended up to 4000 Accuracy Resolution Repeatability 0 1 of Span 0 1 0 1 of span Thermal drift 0 03 of span per 10oC Connector M12 male 4 pin Coding A Sensor MTBF More than 10 years Sensor wetted materi...

Страница 4: ...0xW73xD42 250 grams Sigfox Device only Housing Polycarbonate IP67 Mounting Wall mount bracket Sensor cable 2m sensor cable with M12 male connector 4 Dimensions 4 1 Dimensions of the Sigfox sensor 4 2...

Страница 5: ...Sigfox Sensor Bracket Fuel Sensor Installation tool 5 Scope of delivery...

Страница 6: ...times of alarm did not pass the limit of number of alarms then it will send data to Base station immediately 2 When the sending time interval is reached it will send data to Base station immediately r...

Страница 7: ...ccess mechanism throughput coexistence with other radio technologies etc Each radio configuration includes 4 uplink classes 0u 1u 2u and 3u The Sigfox network globally works within the ranges from 862...

Страница 8: ...new emission before 20 s Listen Before Talk Devices must verify that the Sigfox operated 200 kHz channel is free of any signal stronger than 80 dBm before transmitting Sigfox s high limit EIRP recomm...

Страница 9: ...t a group Step 4 Fill in the required information Click on the text as shown below Note Some of our products may not have end product certification in time to add the product to Backend Sigfox please...

Страница 10: ...he box as shown below to register as a prototype When the sensor sampling time interval is reached for example 2 minutes the Sigfox node will wake up and switch ON 6 3 Measurement principle of Sigfox...

Страница 11: ...W_ALARM_SETPOINT_FACTOR Low alarm setpoint for calculated value 8 bit unsigned integer LOW_ALARM_SETPOINT HIGH_ALARM_SETPOINT LOW_ALARM_SETPOINT_FACTOR 200 0 ALARM_ENABLE Enable Disable ALARM event 0b...

Страница 12: ...fox Downlink tab 0b0000 Data name Description Encoding or Possible values Length in bits EVENT_ID Unique ID identifying the device event 4 bit unsigned integer 0 START_UP 1 HEARTBEAT 2 PARAMETERS_UPDA...

Страница 13: ...load EVENT_ID HW_VERSION FW_VERSION LATEST_SIGFOX_ DOWNLINK 10 0 bits 4 4 8 64 Value 0b0010 2 yes yes yes Size FORCE_DATA led blink SKY BLUE Payload EVENT_ID HW_ ERROR reserved ALARM BATTERY_LEVEL res...

Страница 14: ...LOW_ALARM_SETPOINT_FACTOR ALARM_ENABLE ALARM_PERIOD LED_BUZZER_ENABLE 8 0 bits 32 8 1 3 1 Value yes yes yes yes yes HEARTBEAT_PERIOD MEASURE_PERIOD TX_REPEAT CYCLIC_DATA_PERIOD DEVICE_RESET DOWNLINK_T...

Страница 15: ...Description Range Default Format Property Comment 270 10E 3 16 4 CURRENT_CONFIGURATION hex Read Write 274 112 3 16 1 SERVER_CONFIG uint16 Read Write 0 Send to Sigfox Network 1 Send to Dongle 276 114...

Страница 16: ...status PCB temperature Measured value alarm status Step to configure check data Step 1 Install the Modbus Configurator Software in the link below https filerun daviteq com wl id yDOjE5d6kqFlGNVVlMdFg1...

Страница 17: ...ion port Step 5 Import the configuration file by importing the csv file Go to MENU FILE Import New select the file with name CONFIGURATION TEMPLATE FILE FOR SIGFOX CAP10 SENSOR FW1 0 csv in the link b...

Страница 18: ...se station but the distance will be reduced significantly 9 Installation 9 1 Locate the good place for Radio signal ATTENTION DO NOT install the Sigfox sensor or its antenna inside a completedmetallic...

Страница 19: ...able 9 2 2 Site installation WARNING The sensor must be securely fixed near the measuring area Default communication of CAP10CNR RS485 Baudrate 19200 Data bit 8 Stop bit 1 Parity None Modbus Slave add...

Страница 20: ...Steps for battery installation Step 1 Open the cover by using flat head screwdriver 9 3 Battery installation...

Страница 21: ...ry Step 3 Insert the top plastic housing and locking by L hex key ATTENTION REVERSED POLARITY OF BATTERIES IN 10 SECONDS CAN DAMAGE THE SENSOR CIRCUIT ATTENTION When reinstalling the cover pay attenti...

Страница 22: ...switch has malfunctioned Or place the Magnet key not right position Locate the correct position for magnet key Read the status of the magnetic switch via modbus when powering or attaching the battery...

Страница 23: ...Connection to Antenna problem Check location of Sigfox node and distance to base station Check the antenna connector in the PCB Manufacturer Daviteq Technologies Inc No 11 Street 2G Nam Hung Vuong Re...