15. Replace the junction board cover.

16.

R

eplace the two cap plates. (Note that the closed plate goes on top.) 

17. Replace the solar bracket, being 

careful to use the correct holes in the 
bracket as shown.

18. Align the top of the screws with the 

holes in the mounting base. 

19. Replace the nuts, lock washers and 

flat washers.

20. Reconnect the temperature/humidity 

sensor cable.

Replacing the Fan Motor and Batteries 

To replace the fan motor and batteries in the 24-Hour Fan-Aspirated Radiation Shields, use 
product no. 7758B: Standard Motor Kit for Fan-Aspirated Radiation Shield with Batteries.

Troubleshooting

“I am not receiving data from my sensors.”

Make sure the sensor cable is firmly connected. Try reseating the connections. 

“My data does not seem to be accurate.”

Make sure the screened opening at the bottom of the radiation shield is not blocked and air 
can circulate up the tube. Make sure the fan is running, by listening for it or by placing a 
small piece of tissue paper against the screen under the shield.

“The fan is not running.”

Make sure the solar panel cable is firmly connected. If you have changed the batteries, make 
sure the fan batteries they were inserted in the right orientation (+ to + and - to -).

USE THESE HOLES

Lock Washer

Hex Nut

Flat Washer

Содержание 6832

Страница 1: ...Hour Solar Powered Fan Aspirated Radiation Shield Product number 6832 Temperature Humidity Sensor USER MANUAL Davis Instruments 3465 Diablo Avenue Hayward CA 94545 2778 U S A 510 732 9229 www davisne...

Страница 2: ......

Страница 3: ...the impact of solar radiation on sensor readings Tools for Setup In addition to the hardware provided you will need some or all of the following materials Adjustable wrench or 7 16 wrench Drill and 3...

Страница 4: ...e Pull the tabs You should hear the fan come on Before You Install the Temperature Humidity Sensor Choose a Location It is important to remember to choose a location that best represents the environme...

Страница 5: ...e to the pole use the 8 cable ties to secure the uncoiled sensor cable to pole to prevent fraying in wind Mounting on a Post 1 Using four 1 4 x 1 1 2 lag screws attach the mounting bracket to the surf...

Страница 6: ...ris or insect nests several times a year and thoroughly clean as often as necessary A buildup of material inside the shield reduces its effectiveness and may cause inaccurate temperature and humidity...

Страница 7: ...convenient work place such as a table a piece of cardboard or a pickup truck tailgate Note Take note of the cable placement and routing as you disassemble the shield so you can replace them correctly...

Страница 8: ...move the two cap plates Plates Screen Stand offs Fan Plate Temp Humidity Cable Solar Panel Cable Plugged into Junction Board Closed Cap Plate Open Cap Plate hole in center Solar Panel Bracket Junction...

Страница 9: ...p into the interior of the radiation shield Replace the screen 13 Replace the temperature humidity sensor It fits one way into the slots on the side Route the cable up through the channel and replace...

Страница 10: ...rd Motor Kit for Fan Aspirated Radiation Shield with Batteries Troubleshooting I am not receiving data from my sensors Make sure the sensor cable is firmly connected Try reseating the connections My d...

Страница 11: ...Induced Error 4 F 2 C at solar noon insolation 1040 W m2 avg wind speed 2 mph 1 m s Update Interval 10 seconds Alarms High Low Threshold from Current Reading Relative Humidity Resolution and Units 1 R...

Страница 12: ...2 9188 E mail info davisnet com www davisnet com Contacting Davis Instruments If you have questions about your temperature humidity sensor or encounter problems installing or operating the sensor plea...

Отзывы: