background image

Installation & 

Operating Manual

 UVT

VacTubes Solar Systems

Содержание DAYLIFF Ultrasun UVT VacTube

Страница 1: ...Installation Operating Manual UVT VacTubes Solar Systems...

Страница 2: ...EQUIPMENT SPECIFICATIONS 3 INDEX Davis Shirtliff Ltd 2020 Contents herein are not warranted 8 TROUBLE SHOOTING 15 9 TERMS OF WARRANTY 17 3 SYMBOLS WARNINGS 4 4 SITING 5 5 INSTALLATION 6 6 SYSTEM COMMI...

Страница 3: ...be and glass heating elements Storage tank comprising a stainless steel inner cylinder plastic painted insulated galvanised external casing and 1 5kW heating element Separate 8L cold water header tank...

Страница 4: ...3 28m Feeder Tank Tube bracket Outer tank Inner tank Air vent Cold water inlet Support structure For grouting Feeder Tank Support Front horizontal stay channel Front diagonal stay channel Cradle Main...

Страница 5: ...er Out Drain Plug Ball Valve Cold Water In Non return Valve For grouting Left lower main load channel Left tile channel Left diagonal load channel Right lower main load channel Tail Stock Back right l...

Страница 6: ...be collector out of reach of children WARNING WARNING Installers must adhere to the valid work protection regulations in particular when working on the roof Anti fall protection must be employed whene...

Страница 7: ...t connect any pressure relief device to the vent pipe of this solar water heater 4 SITING Correct siting is critical for the effective operating of a solar water heater the following being important g...

Страница 8: ...or installation South of the Equator Installation with feeder tank Feeder Tank Fig 2 Fig 3 The frame supplied with the Solar Tank is a dual purpose frame that can be used either on a flat roof or on a...

Страница 9: ...that when the Feeder Tank is in position it stands vertical this is important because of the operation of the control valve within the feeder tank Working on roof areas is dangerous particularly in th...

Страница 10: ...and the tank should be screwed into position using PTFE thread tape The final position of the Feeder Tank is correct when the inlet is facing the end of the Main Tank that it is closest to Fig 5 6 Co...

Страница 11: ...le weld breaking Fig 7 10 To reduce heat loss in the pipelines 3 4 outlet points are recommended In case the outlets exceed this or the water line is long it is recommended to expand the capacity of t...

Страница 12: ...tion is required when handling them to avoid breakages CAUTION Solar tanks are heavily insulated and the tubes pass through an aperture in the insulating foam before engaging with the silicon seal fit...

Страница 13: ...of the tank making it watertight Fit the dust seal a black white slightly dished ring seal supplied with the tubes The purpose of this is to exclude dust and dirt from the area around the silicon seal...

Страница 14: ...r is filled early in the morning when the temperature within the tubes is low to avoid damage to the glass tubes CAUTION 13 After the installation allow the solar water heater to heat the water for a...

Страница 15: ...will help to improve the overall efficiency of the solar water heater Hot water will flow from usage point only after unheated water in pipeline flows out first Plan the consumption of hot water in q...

Страница 16: ...k to make sure it s not damaged and that no rainwater runs into the tank insulation Also check for any rusting in the plumbing lines To drain the water from solar water heater for cleaning or repair d...

Страница 17: ...er to sunlight Excessive water consumption undersized Plan water usage as per installed c a p a c i t y I n c a s e o f h i g h consumption use the electric back up Not getting hot water Incorrect con...

Страница 18: ...the controller The solar water heater or plumbing line has a leak Determine the source of the leakage and fix If the problem persists call authorised service provider The solar water h e a t e r i s...

Страница 19: ...cludes defects caused by fair wear and tear the effects of careless handling lack of maintenance faulty installation incompetence on the part of the equipment user Acts of God or any other cause beyon...

Страница 20: ...INS465A 09 20...

Отзывы: