Davies Craig 0401 Скачать руководство пользователя страница 1

 

 

 

 

 

 

P/No. 0960 

 

 

 

 

 

PART NO. 0401 & 0404 - THERMAL SWITCH INSTALLATION INSTRUCTIONS 

(12 & 24 VOLT) 

BEFORE BEGINNING INSTALLATION, READ THESE INSTRUCTIONS FULLY.

 

Note: For automobile applications, controller terminals marked 

as “H” & “C” (terminal 6 & 7 in wiring diagram) can be used for either ignition or to the 

relay positive. The earth terminal on controller (not shown in wiring diagrams) is not applicable for automobile applications.

 

INSTALLATION OF THERMAL SWITCH 

1.

 

When  the  engine  is cold,  remove  the  top  radiator  hose  at  the 
radiator end.

 

 

2. 

Mount  the  Thermal  Switch  to  the  bracket  using  the  two  small 
screws provided. Do not remover the two large screws holding 
the  thermal  switch  together.  IF  THEY  ARE  REMOVED  THE 
WARRANTY WILL BECOME VOID. 

 

 

3. 

Mount  the  bracket  onto  a  panel  near  the  radiator  so  that  the 
stainless steel bulb will easily reach into the top radiator hose. 
Ensure that the adjustment shaft is accessible. Fix the bracket 
in place with the two large self-tapping screws provided. 
 

4. 

Lay  the  rubber  seal  along  the  radiator  ferrule  and  place  a 
section  of  the  stainless  steel  capillary  of  the  Thermal  Switch 
down the groove in the rubber seal. Keep the capillary loosely 
coiled  and  avoid  sharp  bends.  Do  not  pass  the  bulb  further 
down the hose than is necessary as the constant movement of 
the  engine in relation  to  the  radiator may  cause  fatigue of the 
capillary.  The  seal  and  tube  may  be  held  in  place  with 
insulation tape. 

 

Fit the hose and clamp so that the clamp is over the centre of 
the rubber seal and the clamp screw is in the opposite side of 
the tube to the capillary and seal. 

A good silastic type sealant 

may be useful if there is a persistent leak. 
 

5. 

Top up the radiator with the appropriate coolant. 
 

6. 

For wiring purposes, please refer to appropriate wiring diagram 
overleaf. 

WARNING

:

 

Do  not  use  the  vehicle’s  engine  management 

system  or  wiring  connected  to  the  management  system  as  an 
ignition  source  as  it  may  cause  failure  of  the  management 
system and/or the electrical system.  The ignition source must be 
a steady positive supply of 12-24VDC. 

 

SETTING THE ADJUSTABLE THERMAL SWITCH

 

1. 

Install control know on the shaft. 
 

2. 

Turn  on  the  ignition  and  rotate  the  adjustment  know  anti-
clockwise  until  it  stops.  The  fan(s)  will  run  if  the  engine 

temperature  is  above  40

°

–  if  the  fan(s)  do  not  cut  in, 

partially warm the engine to bring the engine temperature into 
the range of the Thermal Switch. 

 

3. 

Check that the fan(s) rotate in the correct direction. If the fan(s) 
rotate in the wrong direction, swap the two wires connected to 
the motor leads (reversing the polarity). 

 

4. 

Ensure  that  all  electrical  connections  are  permanent  and 
properly  insulated  and  that  all  wiring  is  fitted  so  as  to  avoid 
sharp edges and hot parts of the engine. 

 

5. 

Turn the adjustment know fully clockwise. 

 

6. 

Run  the  engine  until  the  engine  temperature  is  about  halfway 
between  “normal  highway  operating  temperature”  and  “too 
hot”. This will indicate a coolant temperature between 5

°

C and 

10

°

C higher than normal. 

 

7. 

Immediately  turn  the  adjustment  shaft  very  slowly  anti-
clockwise, just until the fan(s) switch on, and no more. 

 

8. 

Allow the fan(s) to run long enough to reduce the temperature 
by  approximately  the  thickness  of  the  temperature  gauge 
needle  before  the  Thermal  Switch  turns  the  fan(s)  off.  On  a 
cool  day  it  should  run  between  30  and  60  seconds  at  a  time, 
on a hot day somewhat longer. 

NOTE:

  If  the  fan(s)  run  for  more  than  a  few  minutes  at  a  time, 

turn  the  adjustment  clockwise  slightly  to  increase  the  cut-in 
temperature.  The  fan(s)  must  be  set  to  cut-in  above  normal 
operating  temperature  otherwise  they  will  run  more  frequently 
and for longer periods than necessary, and you may not achieve 
all the benefits of electric fan cooling. 

NOTE:   

Remember  that  coolant  under  pressure  in  a  radiator 

boils at about 118

°

C. 

FAILURE  TO  COMPLY  WITH  ALL  THE  INSTRUCTIONS  OR 
TAMPERING  WITH  THE  PRODUCT  MAY  INVALIDATE  THE 
MANUFACTURERS WARRANTY. 

If  in  any  doubt  about  any  of  these  instructions,  consult  your 
retailer or DAVIES, CRAIG direct on +61 (3) 9369 1234. 

WARRANTY: 

We hereby guarantee that for a period of  2 years 

from  the  date  hereof  we  shall  replace  your  Electronic  Thermal 
Switch,  if  it  is  faulty,  provided  that  such  a  fault  is  directly 
attributable  to  a  defect  in  workmanship  or  materials  used  in  the 
manufacture  of  the  Electronic  Thermal  Switch.  Labour  and 
consequential costs are excluded.  

Register Warranty at: 

 

www.daviescraig.com.au

 

77 Taras Avenue 
P.O. Box 363 
Altona North, Vic 3025 Australia 
Phone: +61(0)3 9369 1234 
Fax:   +61(0)3 9369 3456 
E-mail: [email protected] 
Web: www.daviescraig.com.au 

 

 

 

 

 

 

40°C 