DigaStudio Installation Notes

Page 5 of 15

Before you come into contact with any electronic components make
sure that you are grounded and have discharged any static electricity!

1.  Turn the PC off and open the case so that you have access to the rear slot-covers.

2.  Select any free slot and remove its slot-cover. (Note: no ISA slot will be required).

3.  Mount the slot-adapter in the space left by the slot-cover.

4.  Attach an internal power cable to the adapter. Use the supplied Y-cable if no spare power cables

are available.

5.  Make sure that there are no loose parts (screws, washers, etc) inside the PC and close the cover.

6.  Connect the slot-adapter to a free RS-232 interface (COM port). Use either the 25 pol sub-D con-

nector or the long (2m) cable with the 9 pol sub-D connector depending on how the RS-232 inter-
faces are configured. Use the 

lower

 connector on the slot-adapter.

7.  Now use the long (5m) connection cable to attach the slot-adapter with the DigaStudio Box. On the

slot-adapter use the 

upper

 connection, on the DigaStudio Box use the connection labelled 

PC

.

2.3 PC software

The necessary software is included on diskette or will be sent via email

1

. The software is comprised of

the two files DSINTERFACE.EXE and DIGASTUDIO.EXE.

Proceed as follows to install the software:

1.  Copy the two files into any directory on your computer. If the DigAS system is already installed on

your system then copy the two files into the DigAS system root.

2. First start the interface driver DSINTERFACE.EXE. In the system tray this program’s icon

should be visible.

 

3. Click with the right mouse button on this icon and from the context menu select

the option SHOW. This brings up a larger window with the name DigaStudio In-
terface Manager.

 

                                                     

1

In the future the latest updates can be downloaded from our mailbox. Information concerning updates is
available in our ISDN mailbox and on our internet homepage http://www/david-gmbh.de.

Содержание DigAS DigaStudio

Страница 1: ...DigaStudio DigAS...

Страница 2: ...ration 8 4 1 Manual configuration 8 4 1 1 Channels 1 4 9 4 1 2 Sensitivity 9 4 1 3 I O Settings 9 4 1 4 Limiters 9 4 1 5 Key assignments 9 4 1 6 Program Settings 10 4 2 Configuration via profiles 10 4...

Страница 3: ...ion keys 1 set alternative fader buttons red blue PC connection kit comprising RS422 PC slot blanking plate adapter power supply cable RS422 connection cable DigaStudio Box PC adapter 5 m connection c...

Страница 4: ...t is available for direct analog connection of an PCX card PCX The necessary audio cable is available as an optional extra make sure that the cable is connected the right way around as indicated by th...

Страница 5: ...the slot adapter 7 Now use the long 5m connection cable to attach the slot adapter with the DigaStudio Box On the slot adapter use the upper connection on the DigaStudio Box use the connection labell...

Страница 6: ...flict exists another application is using the COM port If necessary correct the situation by repeating step 4 6 Close the window by clicking on the HIDE button The icon should still be visible in the...

Страница 7: ...if this has not already been done via the Autostart folder The respective icon should be visible in the system tray 2 Start the actual application DIGASTUDIO EXE In the upper left corner the DigaStudi...

Страница 8: ...ned in the DigaStudio User Manual which will be available at a later date As a general rule the last active system configuration prior to the system being turned off is retained and is loaded unchange...

Страница 9: ...TE EQ buttons allow the current EQ settings to be quickly copied to other channels 4 1 2 Sensitivity The input sensitivity for each analog source can be set here 4 1 3 I O Settings A number of paramet...

Страница 10: ...uration Manager DigaStudio Parameter Setup allows for the saving and loading of user or global profiles To create a profile simply enter any name for the profile in the title field then click on the S...

Страница 11: ...nd is automatically activated when the device is turned on Downloading the operating software is normally only required to resolve problems or for function updates e g DSP software The three software...

Страница 12: ...DigaStudio Installation Notes Page 12 of 15 2 Select the required module to be downloaded...

Страница 13: ...mmyy HEX where ddmmyy represents the creation date of the respective software module 4 4 By means of the respective Erase button the load procedure in this example the Master software is initiated Thi...

Страница 14: ...in the respective devices and is automatically activated when the device is turned on Downloading the operating software is normally only required to resolve problems or for function updates e g DSP s...

Страница 15: ...f 15 Landsberger Stra e 87 80339 Munich Germany Fon 49 89 540 139 0 Fax 49 89 540 139 50 Document information Author Andreas Hildebrand Revision date 26 11 98 18 35 File pluto daten david produkt diga...

Отзывы: