The only regular attention your new pressure system requires is to check the pressure
tank’s air charge every 6 months. This is ‘factory set’ at 130kPa (19psi) and can be
checked at the air valve with a tyre gauge. Do not charge tank to a higher pressure
than 130kPa.
To check air pressure in tank:
1. Switch off pump.
2. Open outlet nearest to pump to release water pressure.
3. Charge tank to 130kPa (19psi) using air pump and check
with tyre gauge.
4. Switch on.
5. Close outlet.
Water Quality
Where the water being pumped contains high levels of dissolved solids
(hard water) or biological organisms, a scale build up on the Hydrascan
CL sensor plate may occur over time. This will cause the pump to cycle
at higher than normal flow rates (eg while using the shower). To fix the
problem, clean the sensor plate, using a blunt object, such as a timber
icy pole stick or toothbrush - as illustrated.
Trouble Shooting Check List
a) MOTOR RUNS FOR SHORT PERIOD ONLY WHEN SWITCHED ON BUT DOES
NOT PUMP - LOW PRESSURE INDICATOR LIGHT REMAINS ILLUMINATED
1. Suction line and pump body not filled with water.
2. Air leaks in suction lines or suction pipe not under water.
3. Air trapped in suction lines (also possible with flooded suction due to uneven
rise in piping; eliminate humps and hollows).
4. No water at source or water level too low.
5. Valve on suction lines closed.
b) PUMP SWITCHES ON AND OFF FREQUENTLY (CYCLING)
1. Check that tank air charge is 130kPa (19psi).
2. Cycling may occasionally be caused by float valves filling tanks. This can be
overcome by fitting a Davey Supercell 8C or 18C tank in place of the priming
plug.
3. Leaking taps, float valves etc. check plumbing.
4. Leaking check valve/foot valve.
5. Scale on sensor - see Water Quality.
c) MOTOR DOESN’T START WHEN SWITCHED ON - LOW PRESSURE
INDICATOR LIGHT NOT ILLUMINATED
1. Power not connected or no power available from supply outlet.
2. Supply voltage too low.
3. System already primed and pressurised.
d) MOTOR DOESN’T START WHEN SWITCHED ON - LOW PRESSURE
INDICATOR LIGHT IS ILLUMINATED
1. Supply voltage too low.
2. ”Over temperature” cut-out tripped - switch off, wait 10 minutes and switch on
again.
3. Motor not free to turn - e.g. a jammed impeller.
4. Internal motor fault.
e) PUMP WILL NOT STOP
1. Flow Cone not fitted in Hydrascan
®
.
2. Air lock in Hydrascan
®
.
3. Water leaks on discharge side of pump.
f) PUMP WILL OPERATE NORMALLY INITIALLY BUT WILL NOT RESTART ON
WATER DEMAND - LOW PRESSURE INDICATOR LIGHT NOT ILLUMINATED
1. Power supply problem - see c) 1 or c) 2 above.
2. Static discharge head too high - measure vertical height to top outlet.
i. If height over 10 metres, consult your Davey dealer for advice.
ii. If height less than 10 metres, adjust the cut-in screw setting.
3. Suction depth too great.
4. Suction air leak.
5. Hot water in suction pipe (75°C+).
g) PUMP WILL OPERATE NORMALLY INITIALLY BUT WILL NOT RESTART ON
WATER DEMAND - LOW PRESSURE INDICATOR LIGHT IS ILLUMINATED
1. Suction depth too great.
2. Suction air leak - pump has lost prime.
3. Blocked impellers or suction.
4. Cut-in pressure set too high - must be at least 50kPa below maximum pump
pressure.
After Sales Service
For professional after sales service or repair contact your Davey Dealer. For
assistance in locating your nearest dealer contact the Davey Customer Service Centre
on 1300 367 866.
Adjustable cut-in screw setting
How do I set or adjust?
Quick Set Method
Equipment required:
Flat blade screwdriver
Tea cup
Tyre pressure gauge
Step 1
Fill the pump with water.
Step 2
Start pump and open tap to purge
air out of pipework.
Step 3
Close tap and pump will turn off.
Step 4
Remove cut-in screw cover
and
gently
turn the adjusting screw
anticlockwise until it comes to a stop.
NB
If the pump starts during step 4,
simply wait a few seconds until the pump
stops then repeat step 4.
Step 5 Slowly
draw off
1
/
2
- 1 tea cup of
water and close the tap.
NB If you have a 8 litre or 18 litre tank
draw off
3
/
4
and 1
1
/
2
litres respectively,
close the tap.
Step 6 Slowly
turn the adjusting screw
clockwise until the pump starts. The pump
will start for a few seconds and then stop.
Step 7
Replace the cut-in screw cover.
Congratulations: Your pump is ready to
use.
Accurate Method
Equipment required:
Hydrascan
®
test kit
Flat blade screwdriver
Fit Hydrascan
®
test kit to top of
Hydrascan
®
to allow test to be conducted
at the pump.
Step 1
Fill the pump with water.
Step 2
Start pump and open tap to purge
air out of pipework.
Step 3
Close tap and pump will turn off.
Step 4
Remove cut-in
screw cover and
gently
turn the adjusting screw
anticlockwise until it
comes to a stop.
NB
If the pump starts
during step 4, simply wait
a few seconds until the
pump stops then repeat
step 4.
Step 5
Slowly
open
the tap and allow the
pressure gauge to drop
to the desired cut-in pressure. Close the
tap to hold the system at this pressure.
Step 6
Slowly
turn the adjusting screw
clockwise until the pump starts. The pump
will start for a few seconds and then stop.
The low pressure indicator light will be
illuminated momentarily when the pump
first starts. If the pump stops and the light
does not go out adjust to a lower cut-in
pressure or consult the trouble shooting
guide.
Step 7
Replace the cut-in screw cover.
Congratulations: Your pump is ready to
use.
P/N
48023-9
Supersedes
P/N
48023-8
DA
VEY W
A
TER PRODUCTS GUARANTEE FOR AUSTRALIA & NEW ZEALAND
Davey XP Pressure systems fitted with Hydrascan
®
control and sold after 31 Januar
y 1995 are guaranteed for a period of two years from the date
of original pur
chase to be free of material or manufacturing defects. Should any part fail as a result of such defects within this period, the pressure
system will be repaired free of charge. Additionally
, a three year pro-rata, parts only guarantee commencing from the end of the two years fol
-
lowing pur
chase shall apply only to the Hydrascan
®
control unit and to any pump component damaged as a direct consequence of a Hydrascan
®
malfuction.
TERMS AND CONDITIONS
1.
This guarantee applies to all states and territories of Australia and New Zealand only and is subject to the provisions of the T
rade Practices
Act (Aust.), the Goods and Consumer Protection Legislation of the various Australian states and the Consumers Guarantee Act 1993 (NZ) as applicable.
2.
The guarantee period commences on the date of original pur
chase of the equipment. Evidence of this date of original pur
chase must be
provided when claiming repairs under guarantee. It is recommended you retain all receipts in a safe place.
3.
This guarantee covers parts and workshop labour only
. Goods should be for
warded, with proof of date of original pur
chase, to an Authorised
Davey Ser
vice Centre freight paid.
4.
The pro-rata parts only guarantee means that after two years the owner will pay all labour costs for repairs and pay for parts used on the fol
-
lowing basis: for 25-36 months from pur
chase - 40% of list price; for 37-48 months from pur
chase - 60% of list price; for 49 -60 months from
pur
chase - 80% of list price.
NOTE: This guarantee only applies to Hydrascan
®
or parts damaged through a
Hydrascan
®
malfunction.
5.
This guarantee is subject to due compliance by the original pur
chaser with all directions and conditions set out in the Installation and Operat
-
ing Instructions. Failure to comply with these instructions, damage or breakdown caused by fair wear and tear
, negligence, misuse, incorrect
installation, chemical or additives in the water
, inadequate protection against freezing, rain or other adverse weather conditions, corrosive or
abrasive water
, lightning or high voltage spikes or through unauthorised persons attempting repairs are not covered under guarantee. The
product must only be connected to the voltage shown on the nameplate.
6.
W
ithout limiting the original pur
chaser’
s entitlements under the T
rade Practices Act (Aust.), the Goods & Consumer Protection Legislation of
the various Australian states, or the Consumers Guarantee Act 1993 (NZ), Davey shall not be liable for any loss of profits or any consequential, indirect or special loss, damage or injur
y of any kind whatsoever arising directly or indirectly from the product or any defect.
7.
Where the T
rade Practices Act (Aust.), the Goods and Consumer Protection Legislation of the various Australian states and the Consumers
Guarantee Act 1993 (NZ) does not apply
, Davey shall not be liable for any loss of profits or any consequential, indirect or special loss, dam
-
age or injur
y of any kind whatsoever suffered by the pur
chaser arising directly or indirectly from the product or any defect and the pur
chaser
shall indemnify Davey against any claim by any other person whatsoever in respect of any such loss, damage or injur
y.
8.
Nothing in this guarantee is intended to have the effect of contracting out of the provisions of the T
rade Practices Act (Aust.), the Goods and
Consumer Protection Legislation of the various Australian states and Consumers Guarantee Act 1993 (NZ) except to the extent permitted by the various Acts and this guarantee is to be modified to the extent necessar
y to give effect to that intention.
9.
Davey may be collecting personal information from you in order to provide you with a ser
vice. Davey W
ater Products Pty Ltd promises only
to use this information in accordance with the Provisions of the Privacy Act 1988 (Cth) and the Privacy Policy of Davey W
ater Products Pty Ltd
which is available at davey
.com.au.
®
Davey and Hydrascan are registered trademarks of Davey W
ater Products Pty Ltd.
©
Davey W
ater Products Pty Ltd 1999
Please pass these instructions on to the operator of this equipment.
WARNING: When servicing or attending pump, always ensure power is switched
off and lead unplugged. Electrical connections should be serviced only by
qualified persons. If the electrical supply lead of this pressure system is
damaged, it must only be replaced by authorised Davey service personnel as
special tools are required.
Care should also be taken when servicing or disassembling pump to avoid
possible injury from hot pressurised water. Unplug pump, relieve pressure by
opening a tap on the discharge side of the pump and allow any hot water in the
pump to cool before attempting to dismantle.
Always check air precharge in tank - see maintenance section.
During servicing, use only approved, non-petrochemical based oring and gasket
lubrication. If unsure, consult your Davey Dealer for advice.
WARNING: Do not use hydrocarbon based or hydrocarbon propelled sprays
around the electrical components of this pump.
D
av
ey
W
at
er
P
ro
d
u
ct
s
P
ty
L
td
Member of the GUD Group aBn
18 066 327 517
Head Office and Manufacturing
6 Lakeview Drive, Scoresby
, Australia 3179
Ph:
+61 3 9730 9222
Fax:
+61 3 9753 4100
W
ebsite:
davey
.com.au
Customer Ser
vice Centre
Ph:
1300 367 866
Fax:
1300 369 119
E-mail:
sales@davey
.com.au
Interstate Offices
Sydney • Brisbane • Adelaide Perth • T
ownsville
International
6 Lakeview Drive, Scoresby
, Australia 3179
Ph:
+61 3 9730 9222
Fax:
+61 3 9753 4248
AH:
+61 3 9730 9121
E-mail:
export@davey
.com.au
Germany
Kantstrasse 53, 04275 Leipzig Ph:
+49 341 301 0412
Fax:
+49 341 301 0413
E-mail:
n
ew Zealand
7 Rockridge A
venue,
Penrose, Auckland 1330 Ph:
+64 9 570 9135
Fax:
+64 9 527 7654
W
ebsite:
daveynz.co.nz
E-mail:
U.S.
a
. - Davey Pumps Inc.
1005 N. Commons Drive Aurora, Illinois 60504 Ph:
+1 630 898 6976
Fax:
+1 630 851 7744
W
ebsite:
daveyusa.com
E-mail:
*NOTE:
a) For protection, the Davey
®
pump motor is fitted with an automatic “over
temperature” cut-out. Constant tripping of this overload device indicates a
problem e.g. low voltage at pump, excessive temperature (above 45°C) in
pump enclosure.
b) The ‘Hydrascan
®
’ control device may have to be reset after rectifying any of
the above operating troubles. This is done by pushing in the yellow button
and releasing it after 2 seconds.
W
ARNING: Failure to follow these instructions and
comply with all applicable codes may cause serious
bodily injury and/or property damage.
NOTE: Prior to installation remove the red transport
plugs & associated seals from the suction and/or
discharge ports.