background image

Trouble Shooting Check List

a)  Motor runs when switched on but does not pump or pumps poorly
 

1.  Suction line and pump body not filled with water.

 

2.  Air leaks in suction lines or suction pipe not under water.

 

3.  Air trapped in suction lines (due to uneven rise in piping; eliminate 

humps and hollows).

 

4.  No water at source or water level too low.

 

5.  Valve on suction lines closed.

 

6.  Check valve installed in wrong direction.

 

7.  Suction lift too high.

 

8.  Blocked impeller.

b)  Motor doesn’t start when switched on
 

1.  Power not connected.

 

2.  Supply voltage too low.

 

3.  “Over temperature” cut-out tripped.*

 

4.  Motor not free to turn  eg a jammed impeller.

 

5.  Internal motor fault.

Priming and Operation

1.  Fill the pump body with water at the priming hole adjacent to the delivery 

outlet.

2.  Replace priming plug and switch on.

3.  Open gate valve in pump outlet to allow air from suction line to be expelled. 

With long suction lines it may be necessary to reprime the pump more 

than once.

4.  Once prime has been established a strong flow of water out of the pump 

will be evident. Adjust valve to required flow rate.

Spear Point Installations

The pumping capacity of your Dynaprime may need to be adjusted to match 

the water supply available from your bore. This should be done by closing 

the gate valve in the pump outlet until the flow to the sprinklers is equal to the 

water available to the spear point.

Be sure to choose the correct spear point to suit your water supply.

Installa

tion 

and

Oper

ating 

Instr

uctions

for 

Dyna

prime 

X201

Electric 

Pumps

Please pass these instructions on to the operator of this equipment.

Note: For protection, the Davey pump motor is fitted with an 

automatic “over temperature” cut-out.  Constant tripping of this 

overload device indicates a problem eg  low voltage at pump, 

motor overloaded.

Note:  If this pump is allowed to continually pump water 

containing sand or other abrasive material, the effective life of 

the pump will be shortened.

NOTE:  For protection, the Davey pump motor is fitted with an 

automatic reset thermal overload, constant tripping of this overload 

indicates a problem e.g. low voltage at pump, excessive temperature 

(above 50°C) in pump enclosure.

WARNING: Automatic reset thermal overloads will allow the pump to 

restart without warning. Always disconnect the pump motor from the 

electrical supply before maintenance or repairs.

 

 

WARNING: Do not use hydrocarbon based or hydrocarbon propelled

 

sprays around the electrical components of this pump.

WARNING:  When  servicing  or  attending  pump,  always  ensure  power 

is  switched  off  and  lead  unplugged.  Electrical  connections  should  be 

serviced only by qualified persons.

IMPORTANT:  

DO NOT USE petroleum based fluids or solvents 

(e.g. Oils, Kerosene, Turpentine, Thinners, etc) on the plastic pump 

components or seal components.

In accordance with AS 3350.2.41 we are obliged to inform you that this pump is 

not to be used by children or infirm persons and must not be used as a toy by 

children.

Care  should  also  be  taken  when  servicing  or  disassembling  pump  to 

avoid possible injury from hot pressurised water. Unplug pump, relieve 

pressure by opening a tap on the discharge side of the pump and allow 

any hot water in the pump to cool before attempting to dismantle.

W

ARNING:

 Failure

 to

 follow

 these

 instructions

 and

 

comply

 with

 all

 applicable

 codes

 may

 cause

 serious

 

bodily injury and/or property damage.

NOTE: Prior to installation remove the red transport  plugs & associated seals from the suction and/or  discharge ports.

Davey

®

 Repair or Replacement Guarantee

In the unlikely event in Australia or New Zealand that this Davey pr

oduct develops any malfunction within two years of the date of original pur

chase due to 

faulty materials or manufactur

e, Davey will at our option r

epair or r

eplace it for you fr

ee of char

ge, subject to the conditions below

.

Should you experience any difficulties with your Davey pr

oduct, we suggest in the first instance that you contact the Dav

ey Dealer fr

om which you 

pur

chased the Davey pr

oduct. Alter

natively you can phone our Customer Service line on 1300 367 866 in Australia, or 0800 654 333 in New Zealand, or 

send a written letter to Davey at the addr

ess listed below

. On r

eceipt of your claim, Davey will seek to r

esolve your difficulties or

, if the pr

oduct is faulty or 

defective, advise you on how to have your Davey pr

oduct r

epair

ed, obtain a r

eplacement or a r

efund.

Your Davey T

wo Y

ear Guarantee naturally does not cover normal wear or tear

, r

eplacement of pr

oduct consumables (i.e. mechanical seals, bearings or 

capacitors), loss or damage r

esulting fr

om misuse or negligent handling, impr

oper use for which the pr

oduct was not designed or advertised, failur

e to 

pr

operly follow the pr

ovided installation and operating instructions, failur

e to carry out maintenance, corr

osive or abrasive water or other liquid, lightning 

or high voltage spikes, or unauthorized persons attempting r

epairs.  Wher

e applicable, your Davey pr

oduct must only be connected to the voltage shown 

on the nameplate.

Your Davey T

wo Y

ear Guarantee does not cover fr

eight or any other costs incurr

ed in making a claim. Please r

etain your r

eceipt as pr

oof of pur

chase; you 

MUST

 pr

ovide evidence of the date of original pur

chase when claiming under the Davey T

wo Y

ear Guarantee. 

Davey shall not be liable for any loss of pr

ofits or any consequential, indir

ect or special loss, damage or injury of any kind whatsoever ar

ising dir

ectly 

or indir

ectly fr

om Davey pr

oducts. This limitation does not apply to any liability of Davey for failur

e to comply with a consumer guarantee applicable to 

your Davey pr

oduct under the Australian or New Zealand legislation and does 

not affect any rights or r

emedies that may be available to you under the 

Australian or New Zealand Consumer Legislation.

In Australia, you ar

e entitled to a r

eplacement or r

efund for a major failur

e and for compensation for any other r

easonably for

eseeable loss or damage. Y

ou 

ar

e also entitled to have the goods r

epair

ed or r

eplaced if the goods fail to be of acceptable quality and the failur

e does not amount to a major failur

e.

Should your Davey pr

oduct r

equir

e r

epair or service after the guarantee period; contact your near

est Davey Dealer or phone the Davey Customer Service 

Centr

e on the number listed below

.

For a complete list of Davey Dealers visit our website (davey

.com.au) or call:

Installation and operating instructions ar

e included with the pr

oduct when pur

chased new

They may also be found on our website.

AUSTRALIA

Customer Service Centre

6 Lakeview Drive, Scoresby, Australia 3179 Ph: 

1300 232 839

Fax: 

1300 369 119

Email: [email protected] Website: davey.com.au

Davey Water Products Pty Ltd

Member of the GUD Group

ABN 18 066 327 517

NEW ZEALAND

Customer Service Centre

7 Rockridge Avenue, Penrose, Auckland 1061 Ph: 

0800 654 333

Fax: 

0800 654 334

Email: [email protected] Website: daveynz.co.nz

® Davey is a r

egister

ed trademark of Davey W

ater Pr

oducts Pty Ltd.  © Davey W

ater Pr

oducts Pty Ltd 2016.

P/N 47727-7

47727-7_Dynaprime_X201_I&OI.indd   1

12/12/2016   3:35 PM

Отзывы: