background image

16

DAY TO DAY OPERATION

Four Prime rules must be observed if your unit is to give the best possible service:

1. STABILISER

The importance of pool stabiliser cannot be over – emphasised. It is essential in helping retain chlorine 

in your pool. Chlorine is rapidly dissipated by sunlight and the use of stabiliser will reduce this dissipation 

substantially. Without stabiliser, it may be necessary to run the Unit for up to three times as long!
Stabiliser should be added at the rate of 500 grams for every 10,000 litres of water. Stabiliser should be 

maintained at a level of 30 – 50 ppm. Before adding more stabiliser, have your pool water analysed at your 

pool shop to ensure that you do not add too much. 

(FOR OUTDOOR POOLS ONLY, INDOOR DO NOT 

REQUIRE STABILISER)

2. pH AND TOTAL ALKALINITY

A correct pH level must be maintained to prevent problems such as black spot, staining, cloudy water, etc.  

An incorrect pH level can damage the pool. Correct pH levels are as follows; Fibreglass – 7.2 to 7.4 

Concrete & tiled – 7.4 to 7.6 If you allow the pH level to rise to 8.0 or above, the chlorine required could be 

as much as three times the normal amount.
Total Alkalinity should not be confused with pH, although the two are closely related. Total Alkalinity 

determines the speed and ease of pH change. The ideal range is 80 – 150 ppm, or refer to your pool 

professional.
You should use a test kit which includes a test for Total Alkalinity. Low Total Alkalinity can cause unstable  

pH levels – i.e. An inability to keep the pH constant may cause staining, etching and corrosion of metals. 

High Total Alkalinity will cause constantly high pH levels.

3. TDS LEVELS

WARNING: Some people recommend that you put salt directly in the skimmer 

box. This is a very poor practice as it allows very high concentrations of salt 

to be passed through your filtration and other pool equipment.

EcoMineral Salt and Activator are the essential elements by which your Unit operates. Insufficient 

EcoMineral Salt and Activator will damage your Cell.

RECOMMENDED TDS LEVEL RANGE: 4,000 - 6,000ppm

WARNING: Do not add Hydrogen Peroxide to pool water or through 

swimming pool hydraulic or sanitiser system. Use of Hydrogen Peroxide 

will void warranty on Davey products.

EcoMineral Salt and Activator is NOT used up in the sanitisation process or by evaporation. It is only lost 

through backwashing, splash-out, overflow or by leakage from the pool or plumbing. Heavy rain can dilute 

the TDS levels in your pool; therefore TDS levels should be checked during these events.

Low TDS levels will destroy the coating on the Anode plates and will void all Warranty.

The EcoMineral has a built in warning indicator to minimise damage resulting from insufficient TDS levels, 

however, the ultimate responsibility is on the owner to ensure adequate TDS levels are maintained all year round.

4. RUNNING TIMES

These instructions cover EcoMineral for residential use only.
If you run your Sanitiser for 24 hours a day, or for long periods, the Cell life will be greatly reduced. It is important that 

the correct model EcoMineral has been installed on your pool. Many models are available from Davey to cope with 

small courtyard pools up to commercial applications. (Consult your local EcoMineral Dealer for more information).

Note: The EcoMineral guarantee does not apply to commercial or semi-commercial installations, i.e. where the 

system runs more than an average of 8 hours per day over the year. Guarantee on commercial and semi-commercial 

installations is 12 months only on both power supply and cells.

Содержание EMX3600

Страница 1: ...this equipment The installation of this product should be carried out by a person knowledgeable in swimming pool plumbing requirements following the installation instructions provided in this manual...

Страница 2: ...he chlorination process Periodically check the safety flow switch to ensure it is free to move in the direction of flow as indicated by the arrow on the cell see Diagram A Always check Davey s website...

Страница 3: ...POWER SUPPLY 6 PRE START UP PROCEDURE 7 OPERATION OF YOUR ECOMINERAL SYSTEM 8 CONTROL PANEL LAYOUT 9 ECOMINERAL SPECIAL FEATURES 10 AUTOMATIC TIME CLOCK OPERATION 11 MAINTENANCE OF POWER SUPPLY 13 MAI...

Страница 4: ...ar monitoring of the electrolytic cell is recommended The Cell is the clear plastic housing containing the plates During the sanitisation process a white powdery Calcium scale may naturally build up o...

Страница 5: ...d ventilation is necessary for correct operation Return to pool line Suction Line PUMP FILTER ACCESSORIES IN LINE CELL FLOW SWITCH POWER SUPPLY 240V Two self tapping screws and wall plugs have been pr...

Страница 6: ...to the outer titanium rods Fit the white connector to the middle titanium rod as per illustration below EMX2400 EMX3600 NOTE The EcoMineral Cell is supplied with a paddle type flow switch which is to...

Страница 7: ...the terminal holes at right angles and tighten the terminals CONNECTING THE FILTER CIRCULATION PUMP TO THE POWER SUPPLY Insert the 3 pin male plug into the 3 pin female socket located at the bottom o...

Страница 8: ...0ppm 4 When using the Davey EcoMineral Salt and Davey EcoMineral Activator ensure that TDS levels do not exceed 6 000ppm after its addition to the pool 5 Ensure pH levels are between 7 4 7 6 after the...

Страница 9: ...ly for at least 24 hours or until a reading of 3 ppm is reached STABILISER It is essential that pool stabiliser be added and maintained at the rate of 30 50 ppm at all times Do not exceed 100 ppm FOR...

Страница 10: ...w Note Polarity LED may be either A or B whichever is on or brightest The RED Operation LED will indicate a number of different possible problem situations Possible Problem Action TDS Level Below Mini...

Страница 11: ...the TDS level in the pool decreases the wear on the Cell increases Although EcoMineral Salt and Activator is not consumed in the sanitisation process it is lost through splashing backwashing and on ba...

Страница 12: ...ong as the selector switch remains at this position Use the up and down buttons to reach the desired times Hold the buttons down for fast increments Set Timer 1 ON 2 SET THE START TIME FOR THE FIRST R...

Страница 13: ...uction to change time Automatic ON 6 FILTRATION SYSTEM SWITCHES ON AND OFF AUTOMATICALLY ACCORDING TO YOUR SET TIMES Select the Automatic ON position on the selector switch A number 6 will appear on t...

Страница 14: ...chlorite for an extended period Calcium in the plaster surfaces of a concrete pool Because these conditions vary so much check the Cell at least weekly to begin with to see when either scale or a blue...

Страница 15: ...cale is being dissolved from the plates the solution will foam when this foaming action has stopped the Cell is clean and the solution can be returned to the container for future use or discarded appr...

Страница 16: ...that you put salt directly in the skimmer box This is a very poor practice as it allows very high concentrations of salt to be passed through your filtration and other pool equipment EcoMineral Salt a...

Страница 17: ...Control can be turned anti clockwise Test your chlorine level again the following morning at around the same time If your chlorine level is still high repeat the above process until the correct level...

Страница 18: ...l by rain wind and dust There are numerous varieties some are free floating whilst others grow on walls and in cracks and come in different colours Some are more resistant to chemical treatment than o...

Страница 19: ...ng 6 Sanitiser fuse blown 7 Dirty Cell 8 Filter needs back washing 9 Flow switch not connected 10 Insufficient water flow through cell 11 Running times incorrect 12 Main house fuse blown 13 Pump motor...

Страница 20: ...eplacement of product consumables i e seals bearings or capacitors loss or damage resulting from misuse or negligent handling improper use for which the product was not designed or advertised failure...

Отзывы: