background image

 Via monte Nero, 40/B – 21049 TRADATE (VA) ITALY 
 Phone: +39 (0)331841070 Fax:+39 (0)331841950 - e-mail:

[email protected]

 - 

www.datexel.it

Configuration interface for 

serial ports RS-232

GENERAL DESCRIPTION

The configuration interface PRODAT-04 allows to program, by dedicated software, all the DATEXEL devices of the SMART and SLIM series using both fixed 
workstations and laptops with communication serial ports RS-232 on board.
An internal battery is available for the eventual supply of the transmitter on programming; the battery's output voltage is provided on the connector J4; the same 
voltage is used to power the interface when the output voltage of the serial port is lower of the minimum voltage value necessary to the right working of the 
device (± 7Vdc).
The  1500  Vac  galvanic  isolation  between  the  lines  of  input/power  supply  and  output  is  obtained  by  means  of  opto-couplers  on  the  data  lines  and  a  DC/DC 
converter on the power supply. 
By the dedicated cable (CVPR-03) it is possible to configure the Intrinsically Safe devices.
With the PRODAT-04 are provided the standard cable CVP or the cable CVPR-03, the CD-ROM containing the drivers to install the programming software and 
two Jack connectors for the terminals J3 and J4.
The configuration interface PRODAT-04 is in compliance with the Directive 2004/108/EC on the Electromagnetic Compatibility.

FEATURES

- Adapt to configure the devices of SMART and SLIM series
- Galvanic isolation between the transmission and receiving sides 
- Internal battery
- Connector for external supply input
- Connector for external supply output
- EMC compliant – CE mark
- Programming of the DATEXEL devices, on field too

USER INSTRUCTIONS
A) Use with Standard devices.
The device on programming must be always powered as shown on its technical data-sheet.

The interface PRODAT-04 must be connected to the serial port RS-232 by pin-to-pin cable to the connector J1 ; connect the ' CVP ' cable from the connector J2 
to the PRGM connector of the device on programming.
It is also possible to power the device on programming using the internal battery (only for transmitters) connecting the connector J4 to power supply terminal of 
the transmitter.  

B) Use with Intrinsically Safe devices.
The device on programming must be always connected in according to the Safety Specifications reported on the technical data-sheet of the device .
The configurable devices are the following:
- DAT 1010 IS , DAT 1010 IS/HT;
- DAT 1015 IS , DAT 1015 IS/HT;
- DAT 1065 IS , DAT 1065 IS/HT;
- DAT 2015 IS , DAT 2015 IS/HT;
- DAT 4035 IS , DAT 4035 IS/HT.

The connection diagrams A and B are shown on next page in the section “PRODAT-04: Connections”.
To use the PRODAT-04 refer to the section “Installation Instructions”.

PRODAT-04

Type of battery ( Optional )

6LF22 / 9 Vdc

External supply ( Optional )

10 ÷ 30 Vdc (Transmitters)

18 ÷ 30 Vdc (Converters)

Current consumption

< / =10 mA

RS-232 connection (pin-to-pin cable)

DB9 connector 

CVP/CVPR-03 connection 

4 ways RJ11 plug

External supply IN connection 

2.1 mm JACK connector

External supply OUT connection  

2.5 mm JACK connector

Galvanic isolation among the ways

1500 Vac, 50 Hz, 1 minute

Electromagnetic Compatibility

Emission: EN 61000-6-3 

Immunity: EN 61000-6-1

Operative temperature

0 ÷ 40 °C

Storage temperature (without battery)

-20 ÷ 60 °C

Relative Humidity (not condensing)

0 ÷ 90 %

Weight

about 250  g. 

Optional  accessories

             -  CVPR03  for  the  programming  of  SMART 

series  DAT  xxxx  IS  modules  suitable  for 

application in hazardous areas

                                TECHNICAL SPECIFICATIONS (Typical at 25 °C and in nominal conditions)