Datavideo TPC-700P Скачать руководство пользователя страница 1

 

PoE 

Содержание TPC-700P

Страница 1: ...PoE...

Страница 2: ...VIEW 14 CHAPTER 4 HOW TO TURN ON AND TURN OFF THE POWER OF THE TPC 700 TPC 700P 15 CHAPTER 5 BASIC SETUP 16 5 1 CONNECT BY STATIC IP ADDRESS 16 5 2 CONNECT BY DHCP 16 CHAPTER 6 NETWORK SETTINGS 17 6...

Страница 3: ...THE AUX FUNCTION 42 9 3 CROSS POINT 44 9 3 1 HOW TO USE THE CROSS POINT FUNCTION 44 9 4 FLEX SOURCE 47 9 4 1 HOW TO USE THE FLEX SOURCE FUNCTION 48 9 5 PIP 50 9 6 SETUP 51 CHAPTER 10 INTRODUCTION OF...

Страница 4: ...plete This manual may contain typing errors omissions or incorrect information Datavideo Technologies always recommend that you double check the information in this document for accuracy before making...

Страница 5: ...protect it from overheating do not block or cover these openings Do not place this unit on a bed sofa rug or similar surface as the ventilation openings on the bottom of the cabinet will be blocked Th...

Страница 6: ...under normal operating conditions Adjust only those controls that are covered by the operating instructions in this manual improper adjustment of other controls may result in damage to the unit and m...

Страница 7: ...and batteries are not covered under warranty Warranty only valid in the country or region of purchase Your statutory rights are not affected Three Year Warranty All Datavideo products purchased after...

Страница 8: ...point for the recycling of waste electrical and electronic equipment The separate collection and recycling of your waste equipment at the time of disposal will help to conserve natural resources and...

Страница 9: ...resets Each button can be customized to your liking Multi camera Virtual Studio switching AUX output Crosspoint Flex Source and PIP assignment can be done by the TPC 700 TPC 700P Easy to transport to...

Страница 10: ...10 Chapter 2 System Diagram...

Страница 11: ...connections of the TPC 700 TPC 700P Touch Panel Controller For the details of the TPC 700 TPC 700P please refer to following chapters 3 1 Front View Interface Description Touch Panel This is the touc...

Страница 12: ...12 3 2 Rear View Interface Description Rear Panel This is the rear panel of the TPC 700 TPC 700P Touch Panel Controller It provides standard VESA 10cm x 10cm 7 5cm x 7 5cm mounting holes...

Страница 13: ...rol only If users use the TPC 700 TPC 700P to control the SE 3200 it is no need for this interface to connect due to that the TPC 700 TPC 700P adopts the DVIP protocol to control the SE 3200 USB Inter...

Страница 14: ...ase connect one end of an RJ 45 Ethernet cable to this interface and then please connect the other end of this cable to the device that must be controlled by the DVIP protocol This interface can be us...

Страница 15: ...to turn on the power of the TPC 700 TPC 700P How to Turn Off the Power Use the ON OFF switch Please use the ON OFF power switch which is located on the right side of the TPC 700 TPC 700P to turn off...

Страница 16: ...ing steps 5 1 Connect by Static IP Address 1 Please use an RJ 45 Ethernet cable to connect from the Ethernet interface on the rear panel of the SE 3200 to the DVIP RJ 45 Ethernet interface on the righ...

Страница 17: ...P address mode and the IP address is 192 168 100 102 If users want to connect the TPC 700 TPC 700P to the SE 3200 by the static IP mode please connect the TPC 700 TPC 700P and the SE 3200 with an RJ 4...

Страница 18: ...18 Please follow following steps for operation 1 After opening the TPC 700 TPC 700P interface please select the Setup option 2 Please press the Network button...

Страница 19: ...9 3 Please select the Static from the Addr Mode drop down menu 4 Please press the IP Addr to enter the IP address which is within the same IP range as the SE 3200 After that please press the OK button...

Страница 20: ...20 5 Please press the Network Mask and the Gateway respectively and then please set those two items to be the same value as the SE 3200...

Страница 21: ...21 6 Please press the Save button 7 Please press the Connect button...

Страница 22: ...22 8 Please press the Scan button and then it will scan the IP address of the connected device 9 Please press the Connect button for completing the connection...

Страница 23: ...CP Please follow following steps for connecting the TPC 700 TPC 700P and the SE 3200 by the DHCP Mode 1 Please open the TPC 700 TPC 700P interface and then please press the Setup option 2 Please press...

Страница 24: ...24 3 Please press the DHCP from the drop down menu and then please press the Save button 4 Please press the Connect button...

Страница 25: ...25 5 Please press the Scan button and then it will scan the IP address of the connected device 6 Please press the Connect button for completing the connection...

Страница 26: ...ngs Default Values Please follow following steps for restoring the TPC 700 TPC 700P network related settings to default values 1 Please open the TPC 700 TPC 700P App and then please press the Setup op...

Страница 27: ...3 Please press the Network Def button 4 The following dialogue box will appear Please press the Yes button and then the network related settings will be restored to factory default values successfull...

Страница 28: ...C 700 TPC 700P combination allows users to recall the pre saved 4 camera EFP Chromakey effect virtual scenes easily and rapidly The default setting for the TPC 700 TPC 700P is that the TPC 700 TPC 700...

Страница 29: ...w the corresponding relationship between each interface of the SE 3200 rear panel and the elements for each pre saved virtual scene Connections for the SE 3200 rear panel Reminders for Setting up the...

Страница 30: ...in the middle to shoot the close up for the talent and guests who are sitting in front of the green mat SDI IN 3 CH3 The Camera 3 must be set on the right side to shoot the close up for the talent wh...

Страница 31: ...The built in virtual scene from the SE 3200 Wide Angle virtual scene CH6 The built in virtual scene from the SE 3200 The close up picture is located in the middle CH7 The built in virtual scene from...

Страница 32: ...tual scenes for the SE 3200 and TPC 700 TPC 700P Combination User No Combination of Screen Elements Final Composite Screen 101 Wide Angle with Background CH1 Chromakey CH5 Virtual Scene Full Body Chro...

Страница 33: ...CH7 Virtual Scene Half Body Talent A Chromakey with Virtual Scene 104 Talent B Close up with Background CH4 Chromakey CH8 Virtual Scene Talent B Chromakey with Virtual Scene 105 Talent A PC Source CH...

Страница 34: ...107 Talent A Close up with Background PC Source CH3 Chromakey CH7 Background CH9 PIP Talent A Half Body Chromakey with Virtual Scene Content 108 Talent B Close up with Background PC Source CH4 Chromak...

Страница 35: ...d Still related functions of the SE 3200 for controlling the SE 3200 and for recalling the pre saved virtual scenes directly by the TPC 700 TPC 700P For the setting details and the operating steps ple...

Страница 36: ...for the Datavideo TPC 700 TPC 700P includes Virtual Studio AUX Cross Point Flex Source PIP and Setup options for users to control the SE 3200 remotely by the TPC 700 TPC 700P and an RJ 45 Ethernet cab...

Страница 37: ...users including Wide Angle with background Close up with background Talent A close up with background Talent B close up with background Talent A PC Source Talent B PC Source Talent A close up with bac...

Страница 38: ...38 2 Close up with background 3 Talent A close up with background...

Страница 39: ...39 4 Talent B close up with background 5 Talent A PC Source...

Страница 40: ...40 6 Talent B PC Source 7 Talent A close up with background PC Source...

Страница 41: ...ng steps 1 Please make sure that all of the 8 virtual scenes are saved into the No 101 to No 108 User Mems in advance Moreover please make sure that the SE 3200 main unit the control panel the TPC 700...

Страница 42: ...MULTIV MULTIV2 STILL1 STILL2 FLEX SRC and FLEX SRC2 randomly to the output interfaces such as SDI1 SDI2 SDI3 SDI4 SDI5 SDI5 SDI6 HDMI1 HDMI2 and HDMI3 to be the output sources The main interface of t...

Страница 43: ...43 2 Please select your desired signal source for output from the SELECT area 3 Users can finish the signal assigning for the AUX function 1 2...

Страница 44: ...e input 2 will be shown on the window of input 1 The main interface of the Cross Point is shown as following diagram 9 3 1 How to Use the Cross Point Function Please follow following steps for using t...

Страница 45: ...VIDEO XPT area please tap the OFF button If you want to use the embedded audio of the output video as the output audio source please tap the Follow button How to Enter the PGM AUDIO SETTING Interface...

Страница 46: ...ce to adjust the audio Gain and audio Delay How to Use the PGM AUDIO SETTING Interface 1 Please tap the No 1 arrow to decrease the Audio Gain and Audio Delay 2 Please tap the No 2 arrow to increase th...

Страница 47: ...and four sets of smaller source videos which are overlaid on the background picture Those four smaller source videos will be displayed by their corresponding sub picture windows The FLEX1 FLEX2 button...

Страница 48: ...ture from the SELECT area The source signal channels include BLK 1 12 Still 1 Still 2 MATTE and BARS How to Set the Sub Picture Source Signal for the P In P of Flex Source 1 At first please tap the Sr...

Страница 49: ...ctures which are shared by the FLEX 1 and FLEX 2 to form a variety of Flex Source screen combinations Please refer to following examples for realizing the relation between the FLEX 1 FLEX 2 screen com...

Страница 50: ...cture Source Signal for the PIP 1 At first please tap the Src 1 Src 2 Src 3 or Src 4 button from the PIP area 2 Please tap the source signal channel that you want to use to be the Src 1 Src 2 Src 3 or...

Страница 51: ...orbidden to adjust the scale of X Y or SIZE 9 6 Setup The built in SE 3200 control interface of the TPC 700 TPC 700P allows users to set many parameters including Language Network Connect FW Version M...

Страница 52: ...pressed it will go back to previous page after the setting is saved If the Cancel button is pressed it will go back to previous page directly 2 Network This Network option will show current IP address...

Страница 53: ...this drop down menu 2 IP Address Network Mask Gateway Primary DNS and Secondary DNS Once the IP Addr Network Mask Gateway Primary DNS or Secondary DNS is pressed the keyboard which is shown as followi...

Страница 54: ...m Please press the Scan button and then it will scan current IP address Press the Connect button for connecting the TPC 700 TPC 700P to the SE 3200 Press the Disconnect button for canceling the connec...

Страница 55: ...OFF The screen saver will be closed for easy operation 7 Quit App Press this button can exit current App and go back to the main screen of the TPC 700 TPC 700P 8 Shut Down Press this button can shut...

Страница 56: ...the User Memory of the SE 1200MU is set users can use the TPC 700 Touch Panel Controller to apply their needed default mode directly 10 1 Main Interface of the TPC 700 App Single Dual Please see follo...

Страница 57: ...d effects when shooting the teaching videos For the operation of the TPC 700 please see following steps Step 1 At first please use a D Sub 9 pin to RJ 45 adapter cable to connect from the RS 232 inter...

Страница 58: ...58 Close Up Interactive Pen Mark Logo Interactive Pen Mark Logo...

Страница 59: ...59 Interactive Pen Mark Close Up with Chromakey Slides...

Страница 60: ...60 Dual Camera Effects Close Up Interactive Pen Mark Close Up Interactive Pen Mark Logo...

Страница 61: ...61 Interactive Pen Mark Logo Interactive Pen Mark...

Страница 62: ...62 Close Up with Chromakey Wide Angle with Chromakey...

Страница 63: ...63 Wide Angle with Chromakey Interactive Pen Mark...

Страница 64: ...or the Setting option of the VGB 2000 App please see following section 1 Please click the Setting option of the VGB 2000 App and then you can enter the Setting interface which includes Language Quit A...

Страница 65: ...lified Chinese for you to select After the selection is finished please click the Save button to save the settings Quit APP After clicking the Quit App button you can quit the VGB 2000 App and then go...

Страница 66: ...latest software update files which the folder name is datavideo after the software is unzipped 4 Please copy the whole datavideo folder to the root directory of your USB thumb drive 5 Please insert y...

Страница 67: ...pdate procedure is done Note After the software update is finished there is a file which the file name is done will be generated automatically by the TPC 700 TPC 700P system and will be saved in your...

Страница 68: ...de of the main screen After clicking the Settings button you can enter the Settings interface In the Settings interface there are several options including Network Config Auto execute last APP ON OFF...

Страница 69: ...e last product automatically Click the Auto execute last APP ON OFF once allows you to switch between ON and OFF Install APP Install APP option allows you to install the APP of needed device Please se...

Страница 70: ...nterface of the TPC 700P 6 After the rebooting or unplugging and replugging is finished the device will enter its initial screen Please click Settings 7 Please click Install APP and then the software...

Страница 71: ...emoved Please see following steps for knowing how to uninstall APP by the Uninstall APP option 1 At first please click the Uninstall APP button 2 And then you can select the APP for the model which is...

Страница 72: ...72 Chapter 13 Dimensions Unit mm...

Страница 73: ...7 capacitive touch screen Touch Screen Resolution 800 x 480 Software Upgrade via USB 2 0 interface Control Protocol via RS 232 RJ 45 interface Power DC 12V PoE 802 3af For TPC 700P Only Power Consump...

Страница 74: ...74 Note...

Страница 75: ...75 Note...

Страница 76: ...https www datavideo com product TPC 700 https www datavideo com product TPC 700P May 26 2021 Ver E4 Datavideo Technologies Co Ltd All rights reserved 2020...

Отзывы: