background image

 

 

UNIVERSAL REMOTE

 

RMC-300A 

CONTROL PANEL 

Instruction Manual 

Содержание RMC-300A

Страница 1: ...UNIVERSAL REMOTE RMC 300A CONTROL PANEL Instruction Manual ...

Страница 2: ... PANEL 11 Camera Control 11 Switcher Control 15 Camera Preset Switcher Multi Functional Composite Keys 16 Camera Selection Composite Keys 1 13 12 24 17 Keyboard Brightness Control 17 3 OSD MENU 18 3 1 CAMERA 18 Camera Settings 19 Shutter 19 Gain 19 Focus 19 Video Mode 19 White Balance 19 Video Setting 20 Audio Setting 21 Serial Port Settings 22 3 2 RMC 300A 23 Manage Device 23 System 25 Language 2...

Страница 3: ...not exclude that some information in this manual from time to time may not be correct or may be incomplete This manual may contain typing errors omissions or incorrect information Datavideo Technologies always recommend that you double check the information in this document for accuracy before making any purchase decision or using the product Datavideo Technologies is not responsible for any omiss...

Страница 4: ...s the ventilation openings on the bottom of the cabinet will be blocked This unit should never be placed near or over a heat register or radiator This unit should not be placed in a built in installation unless proper ventilation is provided 7 This product should only be operated from the type of power source indicated on the marking label of the AC adapter If you are not sure of the type of power...

Страница 5: ...as been damaged f When the product exhibits a distinct change in performance indicating a need for service Warranty Standard Warranty Datavideo equipment is guaranteed against any manufacturing defects for one year from the date of purchase The original purchase invoice or other documentary evidence should be supplied at the time of any request for repair under warranty The product warranty period...

Страница 6: ...ing This symbol on the product or on its packaging indicates that this product must not be disposed of with your other household waste Instead it is your responsibility to dispose of your waste equipment by handing it over to a designated collection point for the recycling of waste electrical and electronic equipment The separate collection and recycling of your waste equipment at the time of disp...

Страница 7: ...D screen designed for intuitive device configuration The controller is affordable easy to set up hassle free and perfect for electronic field production 1 1 Features Remote Control via RS 422 or DVIP port Able to control up to 24 Datavideo PTZ block cameras with 7 presets for each camera RGB keyboard for easy identification of keyboard functions User friendly UI on 5 touch screen for easy camera s...

Страница 8: ...8 1 2 System Diagram ...

Страница 9: ...panel operations 2 1 Rear Panel DVIP Control The DVIP port connects the camera controller directly to the PC or a network router via any RJ 45 cables allowing the controller to control up to 24 cameras See DVIP for more details USB 2 0 Firmware Upgrade Port Connect the USB storage device to the USB firmware upgrade port for firmware upgrade See Firmware Update for instructions ...

Страница 10: ... 3 14 GND 15 Preview Channel 4 Power Switch Power switch ON OFF DC IN DC in socket connects the supplied 12V PSU The connection can be secured by screwing the outer fastening ring of the DC In plug to the socket 8 Serial Communication Ports On rear panel of the RMC 300A there are 8 RJ 45 communication ports designed for establishing direction connection with PTZ cameras The communication protocol ...

Страница 11: ...o zoom in or out the selected PTZ camera Note Make sure the LOCK button is not enabled If the LOCK button LED is ON the joystick is locked press the LOCK button to unlock the joystick LOCK Button When enabled the joystick will be in the lock state To resume its functional status simply press the button once to unlock the joystick ...

Страница 12: ... Use the P T joystick to move between options and select Note Before attempting to use the joystick to PAN or TILT a selected camera first make sure the LOCK button is not enabled If the LOCK button LED is ON the joystick is locked press the LOCK button to unlock the joystick Recorder Activation Button REC Press the REC button to activate recording on HDR 80 90 Currently unavailable Recorder Deact...

Страница 13: ...ed at the user s request button push The One Push White Balance data is lost when the power is turned off in other words turning off the machine power resets the One Push White Balance setting The One Push White Balance mode can also be used for white balance calibration Zoom in the camera lens on a white piece of paper which basically serves as a reference for what is white then press the PUSH AU...

Страница 14: ...d camera AUTO IRIS Button Press the AUTO IRIS button to enable auto iris adjustment of the selected camera The 5 inch color touch screen displays the 4 in 1 OSD menu of camera switcher recorder and RMC 300A The knob allows the user to manually adjust the camera s shutter speed focus iris and gain ...

Страница 15: ...ansition Scroll Wheel The wheel triggers transition of PVW and PGM views currently not available CUT Button Pressing the Cut button performs immediate manual switch between PVW and PGM views without the transition effect Currently unavailable MIX WIPE Button Pressing the M W button selects either MIX or WIPE transition effect which can be activated by either moving the transition scroll wheel or p...

Страница 16: ...creen tap the Preset button to activate Presets 1 7 or tap the Preset Shift button to activate Presets 8 14 Note Camera preset composite keys should illuminate purple if presets 1 7 are selected and cyan if presets 8 14 are selected 3 On the physical control panel press the STR button which should illuminate red after that 4 Now on the physical control panel press the PST button to which the PTZ s...

Страница 17: ...s you to select up to two camera numbers as labelled To switch between cameras 1 12 and cameras 13 24 simply press the Camera Shift button on the touch screen Keyboard Brightness Control Keyboard Brightness Slider The LED style slider adjusts the keyboard brightness currently unavailable ...

Страница 18: ... enable Camera Selection Composite Keys which should illuminate yellow the color of the camera button indicating that the keys are activated for selection of cameras 1 to 12 Preset Tap to enable Camera Preset Switcher Multi Functional Composite Keys which should illuminate purple the color of the Preset button indicating that the keys are activated for selection of presets 1 to 7 Camera Shift Tap ...

Страница 19: ... described below Shutter Displays the camera s shutter speed such as 1 30 Note This field currently works for PTC 150 PTZ camera only Gain Currently unavailable Focus Displays the camera s focus mode such as AF or auto focus Video Mode Currently unavailable White Balance Displays the camera s white balance mode such as WB Auto or auto white balance If the camera is in manual white balance mode you...

Страница 20: ... the configuration page Video Setting Tap to open the camera video configuration page Note For PTC 150 and PTC 200 PTZ cameras only video mode video orientation and 3DNR are allowed for configuration for PTC 140 PTC 280 and PTC 300 PTZ cameras the rest of setting options other than video mode video orientation and 3DNR are allowed for configuration ...

Страница 21: ...select the following video orientations as shown in the diagram below Selecting OFF disables this option Other Video Settings Currently unavailable 3DNR Contrast Sharpness Saturation Exposure Hue AGC Gamma HDR High Dynamic Range Audio Setting Currently unavailable ...

Страница 22: ...te that the Serial Port Configs page is currently unavailable Baud Rate Available rates are listed as follows 9600 19200 38400 57600 115200 Data Bits You can choose either 7 or 8 bits but the most frequently used data bit is 8 bits Parity You can turn ON OFF the parity bit Stop Bits You can turn ON OFF the stop bit Flow Control You can turn ON OFF flow control Gear Icon ...

Страница 23: ...23 3 2 RMC 300A The RMC 300A s system configuration interface is illustrated below Manage Device Once you are in the device management page you should be able to see function keys for SCAN LOAD and SAVE ...

Страница 24: ...l of the connected devices within the same network environment will be shown according to the order of the IP addresses Load System will load the latest pre saved order of the devices After the Load button is clicked you will see a progress bar indicating the status of the load Save System will memorize current order of the devices ...

Страница 25: ... the System page you will see the following function buttons Language Currently unavailable Information Tap to view the device information and upgrade device firmware Serial Port Tap to enable disable serial ports ...

Страница 26: ...ed will be numbered from 9 24 as cameras connected to the serial ports take the priority over numbers from 1 8 OFF Cameras 1 24 are reserved for DVIP connection Network Setting Tap to modify network settings The network options are described below Host Name Tap to open an on screen keyboard to modify the device name ...

Страница 27: ...ptions to open a number keyboard and enter relevant settings IP Address Network Mask Gateway Primary DNS Secondary DNS MAC Address 11 22 33 44 55 66 cannot be modified After you have finished configuring the network settings tap Save at the top right corner to save new settings To reset simply tap the Reset button Camera Tally Currently unavailable ...

Страница 28: ...c and Fixed Nonlinear Speed increases exponentially Arithmetic Speed increases linearly Fixed Speed remains constant Screen Saver The screen saver can be automatically activated after the device is idle for a period of time The slider sets the time to activate the screen saver which is basically a black screen on the 5 LCD display To deactivate the screen saver and wake up RMC 300A simply tap any ...

Страница 29: ...note that you will be prompted of an error message if connection to the camera fails An example of the error prompt is shown below Cannot connect to Camera 9 Please reboot that device then scan again 4 1 DVIP DVIP is a communication protocol designed by Datavideo for transfer of data between network devices The diagram below best illustrates the connection between RMC 300A and multiple cameras via...

Страница 30: ...e connection mode is set to static IP you will then need to manually configure the network settings Note RMC 300A s network setting is DHCP by default To access or modify the RMC 300A s network settings tap RMC 300A at the top right corner of the touch screen then tap System at the bottom right corner to open the system configuration page Tap Network Setting then select DHCP or Static IP according...

Страница 31: ...ary DNS After you have configured your static IP settings you can then connect the DVIP port of your RMC 300A to the router and the connection will be immediately established Note The gateway IP should be set to the router IP the first three octets of the IP addresses of the RMC 300A and the gateway IP should be identical Because Static IP involves advanced settings please contact your IT departme...

Страница 32: ... 422 There are 8 RS 422 ports on the rear panel of RMC 300A Each port can only connect one camera at a time The diagram below best illustrates the connection between the RMC 300A and multiple cameras via RS 422 ...

Страница 33: ...own 8 NC Note If you experience difficulties in making your RS 422 connection cable please contact your local dealer or Datavideo office for further assistance and recommendations See the camera s user manual for its RS 422 connection settings After you ve successfully established device connections please tap RMC 300A on the touch screen then tap System to open the configuration page as shown bel...

Страница 34: ...s page is currently unavailable Below are descriptions of various RS 422 configuration options Baud Rate Available rates are listed as follows 9600 19200 38400 57600 115200 Data Bits You can choose either 7 or 8 bits but the most frequently used data bit is 8 bits Parity You can turn ON OFF the parity bit Stop Bits You can turn ON OFF the stop bit Flow Control You can turn ON OFF flow control ...

Страница 35: ...e process which should not be interrupted once started as this could result in a non responsive unit 1 Go to the official product page to download the latest firmware file to the datavideo folder on the USB disk F datavideo rmc300a_fwup Note The directory name datavideo must be in lower case and the firmware file name must not contain any extension and must not be renamed 2 Plug the USB disk conta...

Страница 36: ...36 4 On the System page tap the version number in Information 5 On the Information page tap the Update button ...

Страница 37: ...37 6 While the firmware is being updated you will be prompted as shown below 7 Reboot your RMC 300A after the firmware has been successfully updated ...

Страница 38: ...38 6 Dimensions RMC 300A Unit Millimeters mm ...

Страница 39: ...ection to Camera RS 422 Ethernet Input Output USB 2 0 x 2 10 100 Mbps Ethernet RJ 45 connector x 1 RS 422 RJ 45 connector x 1 Built in Monitor Size 5 Resolution 1280 x 720 Firmware Update USB 2 0 Dimensions 420 x 294 x 134 mm Weight 1 504 Kg Operating Temperature 0 C 40 C 32 F 104 F Storage Temperature 10 C 60 C 14 F 140 F Operating Humidity 10 to 80 non condensing Power DC 12V 19W ...

Страница 40: ...Mar 19 2021 Version E3 Datavideo Technologies Co Ltd All rights reserved 2020 www datavideo com product RMC 300A ...

Отзывы: