InstallatIon and operatIon 9
VENTILATION
airflow is critical for the correct operation of WatCHpaX 60. do not install WatCHpaX 60 in a con-
fined space.
air flows from the front of the unit to the rear (where the connectors are located). always keep both
front and rear panels clear of obstruction at all times.
INSTALLATION
GENERAL
•
this equipment is for professional use for installation at locations where only adults are normally
present. Check the
•
the WatCHoUt 60 must be connected to a properly grounded wall socket (a socket-outlet with
protective earth connection in the building).
•
Both power inlets should be connected when using the device to achieve redundancy.
•
the serial number is located on the base of the unit.
STANDALONE INSTALLATION
place the unit flat.
Mount the four self-adhesive rubber feet (supplied) at the points indicated on the base of the unit.
INSTALLATION IN 19-INCH RACK
the WatCHpaX 60 unit may be mounted in a 19-inch rack by using the optional rack kit. please refer
to separate instructions for rack kit assembly.
OPERATION
IMportant: only use the cables/adapters that are delivered with the WatCHpaX 60 unit, otherwise
dataton aB cannot guarantee full functionality.
the WatCHpaX 60 has two IeC 60320 C14 power inlets and both should be connected when using
the device to achieve redundancy. to obtain full redundancy, we recommend that the two power feeds
come from different electrical feeds/phases. this reduces the risk of the unit failing if one of the electri-
cal feeds is lost.
FIRST POWER ON
the first time you power up a WatCHpaX 60 (after delivery or after a reset) the system will finalize
installation and reboot several times. this procedure will typically take about 5 minutes to complete.
IMportant: do not interrupt this procedure. the first power-on updates firmware of critical compo-
nents. Forcefully powering off the system during the configuration process might result in non-working
hardware components (i.e., capture devices will stop working).
POWER ON
the WatCHpaX 60 is turned on by inserting the dC power cords and then pressing the power button
on the front of the unit. Wake on lan (Wol) may also be used.
POWER OFF
powering down should be initiated from within WatCHoUt production software.