UM-0085-B09
DT80 Range User Manual
Page 234
RG
Alternatively, if a DHCP server was available on the network then you could simply use:
PROFILE ETHERNET IP_ADDRESS=AUTO
By default, the above command is assigned to one of the
DT80
's user defined functions, accessible from the front panel;
see User Defined Functions (P120). This makes it easy to enable Ethernet on a new logger without having to connect to
it.
Setting DNS Server address
To set the DNS server address use
PROFILE NETWORK DNS_SERVER_1=192.168.42.4
PROFILE NETWORK DNS_SERVER_2=192.168.42.5
The first setting is for the primary DNS server; the second is for an optional alternative server, which will only be used if
the primary server is offline.
These settings will be ignored if valid DNS server address(es) were obtained from the DHCP server.
Ethernet Email
To send an email, an Internet-connected computer needs to send the message to an
SMTP server
(Simple Mail
transport Protocol). This server, and its brethren around the world, will then take care of delivering the message to the
specified email address.
Thus in order for the
DT80
to be able to send data or alarm messages via email, it will need to know the name of a
suitable SMTP server. This may be a corporate email server on the local LAN, or it may be a mail service provided by
your ISP, or it may be a third-party public SMTP server on the Internet (both free and paid email services are available).
The
DT80
only supports SMTP servers that:
•
support LOGIN authentication
•
do not require SSL (Secure Sockets Layer) encryption
Note:
gmail
SMTP service
aspmx.l.gmail.com
may be used with some limitation on destination address since it may get filtered by
destination server.
Your email service provider will supply you with the SMTP server name, a username and a password, which you will
need to enter into the
DT80
's profile, as follows:
PROFILE ETHERNET_SESSION SMTP_SERVER=
server name
PROFILE ETHERNET_SESSION SMTP_ACCOUNT=
email account name
PROFILE ETHERNET_SESSION SMTP_PASSWORD=
password
You also need to specify the sender name and email address that the
DT80
will use when sending email. For example:
PROFILE ETHERNET_SESSION SENDER_NAME="Benjamin Bunny"
PROFILE ETHERNET_SESSION [email protected]
If
SENDER_NAME
is not set then the
DT80
model and serial number is used, e.g. "
DT82EM-3 096605
".
The
RETURN_ADDRESS
profile should be set to the email address associated with your account. In the event that an
email sent by the logger is unable to be delivered, a "bounce" error message will normally be sent to this address.
In
dEX
, email settings are configured using the Ethernet email configuration page:
Figure 92: Email configuration page
In the above screen shot, the logger has been set up to use the (fictitious) third party email provider
yourdomain.com
.
The server name, as specified by the provider, is
smtp.yourdomain.com
. The account name (
user
) and password have
also been entered.
Email sent by this logger will appear to come from "
Turbine 12
", with email address of
.
Содержание DT80
Страница 29: ...UM 0085 B09 DT80 Range User Manual Page 29 RG The DT80 File System P114 ...
Страница 184: ...UM 0085 B09 DT80 Range User Manual Page 184 RG Figure 71 DT80 communications options ...
Страница 185: ...UM 0085 B09 DT80 Range User Manual Page 185 RG Figure 72 DT80 communications options integrated modem models ...