2-12
001-4006-101
Transmitted information includes:
z
Short ID
z
Supply Voltage (in Volts)
z
Internal Temperature (in Celsius)
z
Forward and Reverse Power (in Watts) (T-96S and T-96SR only)
z
Received Signal Strength (in dBm)
T-Base Option
Available when connected to a T-96SR Wireless Modem, the “T-Base Option” makes the necessary circuit
changes to allow using the modem as a special diagnostic unit in the T-Base/R. The default value is
“Disabled” (unchecked).
Repeater Mode (Extended T1 RTS-CTS refer to Table 2-8, page 2-13)
The Repeater Mode option extends transmitter turn-on time to allow use in a repeater network. The default
value is “Disabled” (unchecked).
Extended Turn-off (T2)
The Extended Turn-off option extends transmitter turn-off time to enforce a quiet period at the end of each
transmission. Select “Enabled” if data equipment does not clearly terminate each data frame and is
susceptible to extraneous bits (dribble bits) at the end of data transmission. The default value is “Disabled”
(unchecked).
Values are: 4800 b/s = 16 ms; 9600 b/s = 8 ms; 19200 b/s = 4 ms
An end-of-transmission quiet period approximately 8 characters long can be invoked on the T-96SR by
holding its transmitter on briefly after RTS is dropped. This quiet period (which occurs between the last
valid data character and any possible extraneous “noise” bits) may be of benefit to some DTE that would
otherwise be adversely affected by the extraneous bits.
Output Raw Diagnostic Data Only
The Output Raw Diagnostic Data Only option instructs the modem to receive diagnostic information
received from other modems only. Enabling this option disables user data delivery. This function is
provided to use with the Diagnostic Unit incorporated in a T-Base or T-Base/R. The default value for this
option is “Disabled” (unchecked).
Baud Rate
This field selects the RS-232 Interface and Network (over the air) baud rates.
Table 2-7 lists programming possibilities for this field.