Dataplex OPTO-SPLITTER Скачать руководство пользователя страница 17

 

 

DATAPLEX DEVICES—Opto-Splitters User Manual v1.2—09122020                                            

17

 

 

 

 

TECHNICAL

 

SPECIFICATION 

 

 

Model 

1x8 XLR 

1x8 RDM XLR 

1x8 PTB 

1x8 RDM PTB 

1x8 IDC 

1x8 RDM IDC 

Part Number 

DPDDS185XLR 

DPDDS185XLRR 

DPDDS183TB 

DPDDS183TBR 

DPDDS18IDC 

DPDDS18IDCR 

DMX Input 

1x Neutrik XLR 5-Pin Male 

1x Pluggable Terminal Block (PTB) 

1x IDC Terminal Block  

DMX Thru 

1x Neutrik XLR 5-Pin Female 

1x Pluggable Terminal Block (PTB) 

1x IDC Terminal Block 

DMX Outputs 

8x Neutrik XLR 5-Pin Female 

8x Pluggable Terminal Block (PTB) 

8x IDC Terminal Block 

DMX 
Protocol 

DMX-512A 

RDM 

No 

Yes 

No 

Yes 

No 

Yes 

DMX 
Isolation 

Optical, up to 1000V 

Power Input 

100-240 VAC, 50-60 Hz 

Power 
Consumption 

10W 

Power 
Connector 

IEC with fuse holder, accepts IEC C13 cable (included) 

Fuse 

5x20 mm 1A, 250V 

Cooilng 

Convection 

Operating 
Temperature 

-4º to +104º F (-20º to +40º C) 

Unit 
Dimensions 
(WxHxD) 

19 x 1.72 x 4.3 in 

 [482.6 x 43.7 x 109.1 mm] 

19 x 1.72 x 4.1 in  

[482.6 x 43.7 x 104.3 mm] 

Shipping 
Dimensions 
(WxHxD) 

20.5 x 3.5 x 7.38 in 

[520.7 x 88.9 x 187.5 mm] 

Unit Weight 

3.4 lb  [1.54 kg] 

3.2 lb [1.45 kg] 

Shipping 
Weight 

3.8 lb [1.72 kg] 

3.6 lb [1.63 kg] 

 
 
 
 
 

 

 
 

Содержание OPTO-SPLITTER

Страница 1: ......

Страница 2: ...distribution of this document for any other purposes without express written consent Specifications are subject to change without notice The information in this document supersedes all previously sup...

Страница 3: ...IDC 9 SETUP 10 UNPACKING INSTRUCTIONS 10 POWER REQUIREMENTS 10 SAFETY INSTRUCTIONS 10 FUSE REPLACEMENT ERROR BOOKMARK NOT DEFINED OPERATION ERROR BOOKMARK NOT DEFINED RDM DMX SERIAL LINK OPTO SPLITTER...

Страница 4: ...ssume responsibility for any labor expended or materials used to replace and or repair the Product without TMB s prior written authorization Any repair of the Product in the field and any associated l...

Страница 5: ...oring o Multiple connector configurations with IDC PTB or XLR o Rugged Neutrik connectors o Durable RackMount enclosure o Black chassis with rear connectors enables a cleaner front of rack MODEL DIFFE...

Страница 6: ...DATAPLEX DEVICES Opto Splitters User Manual v1 2 09122020 6 MODEL ILLUSTRATION...

Страница 7: ...DATAPLEX DEVICES Opto Splitters User Manual v1 2 09122020 7 DIMENSIONS OPTO SPLITTER 1X8 RDM XLR...

Страница 8: ...DATAPLEX DEVICES Opto Splitters User Manual v1 2 09122020 8 DIMENSIONS OPTO SPLITTER 1X8 RDM PTB...

Страница 9: ...DATAPLEX DEVICES Opto Splitters User Manual v1 2 09122020 9 DIMENSIONS OPTO SPLITTER 1X8 RDM IDC...

Страница 10: ...er user make sure they also receive this instruction booklet o Ensure the unit is connected to proper voltage and that line voltage is not higher than that stated on the device o Make sure there are n...

Страница 11: ...REPLACEMENT Dataplex Opto Splitters use a 1 0A 250V barrel fuse 5x20mm 0 2x0 8 in To replace fuse 1 With a screwdriver open the fuse drawer to access the fuse 2 Remove old fuse and fasten new fuse sec...

Страница 12: ...ng from the lighting console to the 5 pin male input connector of the Opto Splitter 1x8 XLR 3 Connect additional DMX cables to output connectors of the Opto Splitter Mini 1x5 RDM and link them to fixt...

Страница 13: ...diagram for common data positive and data negative conductors 1 Strip the bare end wire insulation back 7mm or roughly inch from cable end 2 Insert bare wires into connector per the diagram below Tur...

Страница 14: ...ows the same diagram for common data positive and data negative conductors 1 Insert a small screwdriver into each of the 3 orange tabs on the IDC connector Using gentle upwards pressure push open the...

Страница 15: ...EX DEVICES Opto Splitters User Manual v1 2 09122020 15 FRONT PANEL LED INDICATORS POWER STATUS INPUT STATUS Indicates whether the DMX signal is received at the input Input status indicators have two s...

Страница 16: ...DATAPLEX DEVICES Opto Splitters User Manual v1 2 09122020 16 REAR PANEL LED INDICATORS INPUT STATUS Indicates whether the DMX signal is received at the input Input status indicators have two states...

Страница 17: ...utrik XLR 5 Pin Female 8x Pluggable Terminal Block PTB 8x IDC Terminal Block DMX Protocol DMX 512A RDM No Yes No Yes No Yes DMX Isolation Optical up to 1000V Power Input 100 240 VAC 50 60 Hz Power Con...

Страница 18: ...an RMA prior to shipping the unit Be prepared to provide the model number serial number and a brief description of the cause for the return Be sure to properly pack the unit any shipping damage result...

Страница 19: ...T H I S P A G E I N T E N T I O N A L Y B L A N K...

Страница 20: ...418 techsupport tmb com LOS ANGELES 1 818 899 8818 LONDON 44 0 20 8574 9700 NEW YORK 1 201 896 8600 BEIJING 86 10 8492 1587 CANADA 1 519 538 0888 A full service company providing technical support cus...

Отзывы: