Battery 0.17 J, 0.33 J 9 V Energizer Value Service Guide
Issue 4, 08/2020
9 of 18
9
WARNING!
Do not connect to mains or line operated equipment (e.g. mains/line power supply). When
performing this test, always use a battery to power the energizer.
To ensure accuracy of measurement, the output voltage of this energizer should be tested using either an
Energizer Performance Meter
(EPM) or a Digital Voltmeter (DVM) (part number
880 0001-487
(822645) PEL,
880 0000-178
(806217) Patriot,
880 0001-528
(824663) Stafix,
880 0001-529
(824724) Speedrite).
0.17 J
8.27
3.88
0.16
2.54
0.15
0.33 J
9.06
4.47
0.32
2.93
0.31
WARNING!
Do not connect to mains or line operated equipment (e.g. mains/line power supply). When
performing this test, always use a battery to power the energizer.
Either use the pulse interval information provided by the Tru-Test Energizer Performance Meter (EPM) or, use a
stop-watch to time the number of seconds it takes for the energizer to pulse 10 times.
1.5