background image

Battery 0.17 J, 0.33 J 9 V Energizer Value Service Guide 

Issue 4, 08/2020 

 

15 of 18 

 

15

 

 

Terms and acronyms are used throughout this service guide. A fuller explanation of them is provided with this glossary. 

Datamars part 
number 

Part numbers are being transitioned from the older Tru-Test manufacturing system format 
(JDE) to the new Datamars part number format (SAP). Both numbers can be used for 
ordering parts for 2020/2021 and are displayed in the format 

SAP #

 (JDE#). For example: 

880 0000-963

 (830037P). 

Datamars Livestock 
Service Portal 

Service guides and other resources are available for service agents to download via a 
website portal called the 

Datamars Livestock service portal

, available at :  

service.tru-

test.com

 

Feedback address 

All feedback communications can be sent by email to

 

[email protected]

 

Firmware 

A specific class of computer software that provides the low-level control for a device's 
specific hardware. Can also be termed internal software or software. 

FFC 

The display and the keypad use FFCs (flat flexible circuits) to connect to the main PCA 
(cables and connectors). 

FPC 

Flexible Printed Circuit. 

LCD 

A Liquid-Crystal Display is a flat-panel display or other electronically modulated optical device 
that uses the light-modulating properties of liquid crystals to display information on a screen. 

PCA 

Printed circuit assembly. 

PCB 

Printed circuit board. 

Pozidriv 

A cross-head screwdriver (and screw) with parallel flanks which prevents the ejection force 
during tightening or loosening. The name Pozidriv is the abbreviation or acronym for 
"positive drive". 

PPE 

Personal Protective Equipment (PPE). What you should wear (as a service agent during 
servicing). 

Return 
Authorisation (RA) 
number 

Before a product or assembly is returned to Datamars Ltd for service or analysis, please 
advise us beforehand so that a Return Authorisation (RA) number can be allocated. The RA 
number will ensure that we are ready for the product when it is received and assist us in 
providing efficient and prompt service. Please mark all packaging with the RA number. 

Содержание Livestock Speedrite SV170

Страница 1: ...Issue 4 08 2020 1 of 18...

Страница 2: ...g please contact your local city recycling office or the dealer from whom you purchased the product For instructions on how to dismantle this product for recycling email service dept datamars com 2020...

Страница 3: ...ng precautions 5 Deciding whether to undertake a repair 6 Service levels 6 Technical bulletins and useful resources 6 Spare parts list 7 Troubleshooting 8 Testing procedures 9 Testing the output volta...

Страница 4: ...lectrical discharge and to keep hands clean from handling metal coatings Safety Glasses Safety plastic glasses for use if operating any machinery that is pneumatic or air driven e g air impact wrenche...

Страница 5: ...age some components on the device Such damage may degrade an electronic component and may result in faults developing within that component over time When working on this device ensure that the correc...

Страница 6: ...izer This service guide and all instructions are designed for Service Level 1 assistance Where more involved or skilled repairs or servicing is required please arrange by contacting Datamars See page...

Страница 7: ...0 0009 738 828185 Each PEL 102BV blue 880 0002 662 828182 Each Patriot P9 17 black 880 0009 737 828183 Each Patura P15 green 880 0002 417 828184 Each Speedrite SV330 red 880 0009 740 828189 Each PEL 1...

Страница 8: ...arent repair or replace parts as required See the parts list on page 1 To replace the handle see page 10 To replace the switch knob see page 11 Test the energizer s output voltage and output energy Me...

Страница 9: ...M or a Digital Voltmeter DVM part number 880 0001 487 822645 PEL 880 0000 178 806217 Patriot 880 0001 528 824663 Stafix 880 0001 529 824724 Speedrite 0 17 J 8 27 3 88 0 16 2 54 0 15 0 33 J 9 06 4 47 0...

Страница 10: ...palm of your hand in the direction shown 2 Continue tapping until the handle slides away from the case lid If the handle has broken off use a flat bladed screwdriver or blunt chisel and a hammer to t...

Страница 11: ...y replace faulty components i e if the switch knob is damaged but the magnet is OK recycle the magnet If the magnet is missing but the switch knob is OK recycle the switch knob 1 Turn the switch so th...

Страница 12: ...2 of 18 2 Holding the switch as shown below use the fingers of your right hand to gently lever the switch up while holding it vertical using the fingers of your left hand 3 Fit the magnet into the new...

Страница 13: ...2020 13 of 18 4 Align the new switch in the 1 o clock 30 position Align it with the spigot and press down firmly Rotate the switch from off to on and check that it clicks into each position 5 Connect...

Страница 14: ...need to recycle the handle and terminal knobs from the old case lid See Replacing the handle on page 10 This applies to house brand models HB17 and HB33 only In order to request a replacement energize...

Страница 15: ...n also be termed internal software or software FFC The display and the keypad use FFCs flat flexible circuits to connect to the main PCA cables and connectors FPC Flexible Printed Circuit LCD A Liquid...

Страница 16: ...ble on the Datamars Livestock service portal EID stick reader An EID electronic identification stick reader in terms of scales is a device that provides a digital readout This is displayed when an ite...

Страница 17: ...he fence earth terminal of the energizer and that is dependent of other earthing arrangements Connecting lead An electrical conductor used to connect the energizer to the electric fence or the earth e...

Страница 18: ...recycling please contact your local city recycling office or the dealer from whom you purchased the product Battery energizers that cannot be connected to mains operated equipment Do not connect to ma...

Отзывы: