1.8 FUME / DUST EXTRACTOR
During the marking process, dust and/or gas may be produced. It is important to use an adequate fume
extractor and/or air filtration.
WARNING!
Marking PVC (or other plastic material) can cause the release of chlorine gas which can be
harmful
to the laser operator and to the marking system itself. Always use adequate fume extractor during
PVC and plastic marking.
1.9 FAN INSTALLATION
The fan supplied with the device must be accurately positioned and fixed on the resonator so that it can work
properly.
The fan must be assembled so that the air flow is aimed at the unit containing the crystal (gold-coloured
section on the resonator).
Figure 10: Fan installation.