INSTRUCTION MANUAL 35
CHAPTER 6
COMMISSIONING AND
CONFIGURATION
RESTART MODE SELECTION AND RESTART FUNCTION
The interruption of a beam due to an opaque object causes the opening of OSSD out-
puts and the stop of the safety light curtain, SAFE condition.
ESPE standard operation can be reset (OSSD safety contact closing = NORMAL OP. condi-
tion) in two different ways:
•
Automatic Restart
, After activation, ESPE resets to Normal Operation once the
object has been removed from the controlled area.
•
Manual Restart
, After activation, ESPE resets to Normal Operation only once the
RESTART function has been activated (see
) and provided that
the object has been removed from the controlled area.
This condition, called interlock, is signaled on the display (see "
).
Figure 1 - Auto/Manual Restart selection