
INSTALLATION
14 SG4 EXTENDED
It is important to position the safety light curtain according to the minimum distance
from reflecting surfaces.
The minimum distance depends on:
•
operating distance between emitter (TX) and receiver (RX);
•
real aperture angle of ESPE (EAA); especially:
for ESPE Type 4 EAA = 5° (
α
= ± 2.5°)
Figure 6 - Minimum distance from reflective surface
The formula to get Dsr is the following:
For ESPE Type 4:
Dsr (m) = 0.13 for operating distance < 3 m
Dsr (m) = 0.5 x operating distance (m) x tg 2° for operating distance
≥
3 m
Distance between homologous devices
The following graphic shows the distance from the interfering devices (Ddo) according
to the operating distance (Ddo) of the couple (TXA – RXA).
If different safety devices have to be installed in adjacent areas, the emitter of one
device must not interfere dangerously with the receiver of the other device.
The TXB interfering device must be positioned outside a minimum Ddo distance from
the TXA – RXA emitter-receiver couple axis.
Figure 7 - Distance between homologous devices
Содержание SG4 FIELDBUS Series
Страница 1: ...SG4 Extended INSTRUCTION MANUAL Safety Light Curtains ...
Страница 8: ...VIII SG4 EXTENDED COMPLIANCE ...
Страница 10: ...X SG4 EXTENDED GENERAL VIEW Figure 1 Safety Light Curtain ...
Страница 123: ...DOUBLE MUTING ARMS INSTRUCTION MANUAL 113 Light curtain Active Passive Arms L Light curtain Active Passive Arms T ...
Страница 133: ......
Страница 134: ......
Страница 135: ......