SG2 MUTING
40/96
7.3 RESET
When ESPE locks into failure state user can go back to Normal Operation with a power cycle or using the
activation of RESET function (non critical failures only).
To activate RESET function the 24VDC normally-open button connected to RESET/RESTART/ALIGN input (pin 3
of M12-12 poles
– RX side) has to be kept pressed for at least 5 seconds in non critical failure state.
For all critical failures a power cycle is necessary.
When in failure state the light curtain can be reset with the procedure explained above except the case of failure on
microprocessor, for which a power cycle is necessary.
Fig 47 - Reset timings
If the error is not removed, the light curtain goes in lockout failure again.
Содержание SG2 BASE Series
Страница 1: ......
Страница 3: ......
Страница 83: ...SG2 MUTING 83 96 Fig 113 Light curtain Active Passive arms L Fig 114 Light curtain Active Passive arms T ...
Страница 96: ...SG2 MUTING 96 96 ...