background image

 

This product is covered by one or more of the following patents. 

European Patent 851,211 B1; 1,111,690 B1; 1,148,346 B1; 1,209,487 B1. 

Italian Patent IT 1,321,772. 

 
 

S5N-PH/MH SERIES 

INSTRUCTION MANUAL 

 
 
 
 
 
 
 
 

IEC 60825-1 

“Caution –

 use of controls or adjustments or performance of 

procedures other than those specified herein may result in hazardous 
radiation exposure

 

CONTROLS 

OUTPUT LED (S5N-

PH/MH…B01/C01/F01) 

The  yellow  LED ON indicates that the N.O. (normally open) output status 
is closed. 

POW ER ON LED 

The green LED indicates that the sensor is operating. 

TRIMMER (S5N-

PH/MH…B01/C01/F01) 

The  trimmer  can  be  used  to  adjust  sensitivity;  the  operating  distance 
increases turning the trimmer clockwise. 
 

W ARNING: The trimmer rotation is limited to 270° by a mechanical stop. 
Do not apply excessive torque when adjusting (max 40 Nmm). 

INSTALLATION 

S5N-PH:

  The  sensor  can  be fixed by means of the M18x1 threaded body 

through  a 

  18  mm  hole,  using  the  specific  washer  and the two CH.24 

nuts enclosed (1.5 Nm maximum tightening torque). 
Amongst  the  various  possible  solutions,  we  suggest  to  choose  the 
combination  that  offers  the  best  visibility  of  the  signalling LEDs and the 
easiest access to the trimmer. 
22 mm nuts, h=8 mm, (2 Nm maximum tightening torque) are available to 
guarantee an improved torque. 

S5N-MH:

  The  sensor can be fixed by means of the M18x1 threaded body 

through  a 

  18  mm  hole,  using  the  two  CH.24  nuts  enclosed  (22  Nm 

maximum tightening torque). 

 
Various  orientable  fixing  brackets  for  both  plastic  and  metallic versions 
are  available  to ease sensor positioning (please refer to the accessories 
listed in the general catalogue). 
The  operating  distance  is  measured from the front surface of the sensor 
lens. 

 

CONNECTIONS 

The connections are compliant to the EN 60947-5-2 standard. 
 

S5N-

PH/MH…B01/C01/F01 

+

 

 

10 … 30 Vdc 

N.C. OUTPUT 

BROWN 

WHITE 

BLACK 

BLUE 

N.O. OUTPUT 

0 V 

 

S5N-

PH/MH…G00 

+

 

 

10 … 30 Vdc 

TEST + 

BROWN 

WHITE 

BLACK 

BLUE 

NOT USED 

0 V 

 

M12 CONNECTOR 

 
 

2

3

1

4

 

 

DIMENSIONS 

24

=

1.5

4

4

2

=

3.8

TRIMMER

mm

=

S50-MH VERSION

POWER ON LED

OUTPUT LED

S50-PH VERSION

69
42
36

without

L
X

X1

M O D E L S

79
43
46

X

X1

L

OUTPUT LED

POWER ON LED

X

4

L
X

79
43

69
38

CABLE VERS.

OUTPUT LED

POWER ON LED

Ø4

POWER ON LED

OUTPUT LED

CABLE VERS.

L

14

12

3.5

14.5

14

trimmer

trimmer

with

M O D E L S

without

trimmer

trimmer

with

24

14.5

15

25

10

10

M12

M18

x1

N°.2 Ø3.8

14

12

4

14.5

14.5

10

M18

x1

61

M12

10

Ø4

 

TECHNICAL DATA 

 

S5N-PH PLASTIC VERSIONS 

S5N-MH METAL VERSIONS

 

Power supply: 

10 … 30 Vdc limit values 

Ripple: 

2 Vpp max. 

Current consumption  
(output current excluded): 

35 mA max. (mod.B01/C01/F01) 

30 mA max (mod.G00) 

Outputs: 

N.O. and N.C.; PNP or NPN

 

(short-circuit protection) 

Output current: 

100 mA max.  

Output saturation voltage: 

2 V max. 

Response time: 

333 

Switching frequency: 

1.5 kHz 

Indicators: 

OUT PUT  LED (YELLOW) (mod.B01/C01/F01) 

POWER ON LED (GREEN) 

Setting: 

sensitivity trimmer (mod.B01/C01/F01) 

Operating mode: 

LIGHT  mode on N.O. output / DARK mode on N.C. output (mod.C01) 

DARK mode on N.O. output / LIGHT  mode on N.C. output (mod.B01/F01) 

Operating temperature: 

-

10 … 50 °C 

Storage temperature: 

-

25 … 70 °C 

Insulating strength: 

500 Vac 1 min., between electronics and housing 

Insulating resistance: 

>20 M

 500 Vdc, between electronics and housing 

Operating distance (typical values): 

B01: 0.1…9 m on R2 reflector 

C01: 0…25 cm 

F01/G00: 0…50 m 

Emission type: 

RED LASER: Class 1 IEC 60825-1 (2014) (mod.B01/C01/G00) 

Class 1 CDRH 21 CFR PART  1040.10 (mod.B01/C01/G00) 

Max. power 

 1 mW; Pulse = 5 

s; 

 

= 645…660 nm; Frequency 

 

25 kHz 

Ambient light rejection: 

According to EN 60947-5-2 

Vibrations: 

0.5 mm amplitude, 10 … 55 Hz frequency, for every axis (EN60068-2-6) 

Shock resistance: 

11 ms (30 G) 6 shock for every axis (EN60068-2-27) 

Housing material: 

PBT   

Nickel-plated brass  

Lens material: 

PMMA 

Mechanical protection: 

IP67 Metal versions type 1 enclosure 

Connections: 

2 m cable 

 4 mm / M12 - 4 pole connector  

Weight:  

75 g. max. cable vers. /25 g. max. conn. vers. 

110 g. max. cable vers. /60 g. max. conn. vers. 

 

SETTING 

Setting of S5N-

PH/MH…B01 

Position the sensor and reflector on opposite sides. 
Turn the sensitivity trimmer to the maximum position. 
Moving  the  sensor  both  vertically  and  horizontally,  determine  the power 
ON  and  OFF  points  of  the  OUTPUT  LED and then mount the sensor in 
the middle of the points defined. 
If necessary reduce sensitivity in order to detect very small targets. 
In  order  to  improve  alignment,  repeat  the  given  procedure  whilst 
progressively reducing the sensitivity. 

Setting of S5N-

PH/MH…F01/G00 

Position the sensor and reflector on opposite sides. 
Turn  the  sensitivity  trimmer  to  maximum:  moving  the  sensor  both 
vertically and horizontally, determine the power ON and OFF points of the 
OUTPUT  LED  and  then  mount  the  sensor  in  the  middle  of  the  points 
defined. 
If  necessary,  reduce  sensitivity  using  the trimmer, in order to detect very 
small  targets.  In  order  to  improve  alignment,  repeat  the  procedure 
detailed above whilst progressively reducing the sensitivity. 

Setting of S5N-

PH/MH…C01 

Turn  the  sensitivity  trimmer  to  minimum: the OUTPUT 
LED is OFF. 
Position the target to detect in front of the sensor.

 

Turn  the  sensitivity  trimmer  clockwise  until  the 
OUTPUT LED turns ON 

(Target detected state, pos.A). 

Remove the target, the OUTPUT LED turns OFF. 
Turn  the  sensitivity  trimmer  clockwise  until the OUTPUT LED turns ON 

(Background detected state, pos.B). 

The trimmer reaches maximum if the background is not detected. 
Turn  the  trimmer  to  the  intermediate  position  C,  between  the  two 
positions A and B. 

TEST FUNCTION (S5N-

PH/MH…G00) 

The  TEST+  input  can be used to deactivate the emitter and verify that the 
system is operating correctly. 
The  receiver  output  should  switch  when  the  test  is  activated  while  the 
beam is uninterrupted. 
The input activating voltage range is 10…30 Vdc. 
 

Datalogic S.r.l. 

Via S. Vitalino 13 - 40012 Calderara di Reno - Italy 
Tel: +39 051 3147011 - Fax: +39 051 3147205 - www.datalogic.com

 

 
Helpful  links  at  www.datalogic.com: 

Contact  Us,

 

Terms  and 

Conditions,

 

Support

 
The warranty period for this product is 36 months. See General Terms 
and Conditions of Sales for further details. 
 

 

For information about the disposal of Waste Electrical 
and Electronic Equipment (WEEE), please refer to the 
website a

www.datalogic.com

 

 
©  2018  -  2019  Datalogic  S.p.A.  and/or  its  affiliates 

  ALL  RIGHTS 

RESERVED. 

  Without  limiting  the  rights  under  copyright,  no  part  of 

this  documentation  may  be  reproduced,  stored  in  or  introduced  into  a 
retrieval  system,  or  transmitted  in  any  form  or  by  any  means,  or  for any 
purpose,  without  the  express  written  permission  of  Datalogic  S.p.A. 
and/or  its  affiliates.  Datalogic  and  the  Datalogic  logo  are  registered 
trademarks  of  Datalogic  S.p.A.  in  many  countries,  including  the  U.S.A. 
and  the  E.U.  All  other  trademarks  and  brands  are  property  of  their 
respective  owners.  Datalogic  reserves  the  right  to  make  modifications 
and improvements without prior notification. 
 

826000422 Rev.C

 

 

MIN 

MAX 

 

CLASS 1 IEC 60825-1 (2014) 

LASER PRODUCT 

S5N-PH VERSION 

S5N-MH VERSION 

TRIMMER 