This product is covered by one or more of the following patents.
European Patent 851,211 B1; 1,111,690 B1; 1,148,346 B1; 1,209,487 B1.
Italian Patent IT 1,321,772.
S5N-Mx SERIES
INSTRUCTION MANUAL
Information on IO-Link communication is available on the last
page of this manual.
CONTROLS
OUTPUT LED (S5N-
Mx…B01/C01)
The yellow LED ON indicates that the N.O. (normally open) output
status is closed.
STABILITY LED (S5N-
Mx…B01/C01)
The green LED ON indicates that the received signal has a reserve
greater than 30% compared to the output switching value.
TRIMMER (S5N-
Mx…B01/C01)
The trimmer can be used to adjust sensitivity; the operating distance
increases turning the trimmer clockwise.
WARNING: The trimmer rotation is limited to 270° by a mechanical stop.
Do not apply excessive torque when adjusting (max 40 Nmm).
INSTALLATION
The sensor can be fixed by means of the M18x1 threaded body through
a
18 mm hole, using the two CH.24 nuts enclosed (22 Nm maximum
tightening torque).
Wide range of accessories available: various orientable fixing brackets
ease the sensor positioning (please refer to the accessories listed in the
general catalogue).
The operating distance is measured from the front surface of the sensor
lens.
C models
: To improve the detection, the
object has to be moved closer or further away
from the front surface of the sensor lens.
In case of lateral translation, the object must
move as indicated in the figure.
CONNECTIONS
The connections are compliant to the EN 60947-5-2 standard.
M12 CONNECTOR
10 … 30 Vdc
-
+
N.O. OUTPUT/
IO-Link
0 V
N.C. OUTPUT
2
3
1
4
DIMENSIONS
24
mm
RADIAL VERSION
FIBRE OPTIC VERSION
57
38
without trimmer
L
X
M O D E L S
with trimmer
67
43
AXIAL VERSION
69
38
without trimmer
L
X
M O D E L S
with trimmer
79
43
CABLE VERSION
24
4
4
M18x1
=
2.5
X
TRIMMER
10
M12
=
Ø4
OUTPUT LED
STABILITY LED
24
=
6.2
4
12
Ø
22
M18x1
Ø
2.2
TRIMMER
54.5
=
M12
10
STABILITY LED
OUTPUT LED
STABILITY LED
OUTPUT LED
14
12
LED STABILITY
LED DI USCITA
6°
4
4
14.5
10
M18x1
L
L
X
M12
50
14.5
72.5
49
14.5
61
14.5
10
TRIMMER
TECHNICAL DATA
S5N-MA AXIAL VERSION
S5N-MR RADIAL VERSION
Power supply:
10 … 30 Vdc (limit values)
Ripple:
2 Vpp max.
Current consumption
(output current excluded):
35 mA max.
Outputs:
N.O. and N.C.; PNP or NPN
(short-circuit protection)
Output current:
100 mA max.
Output saturation voltage:
2 V max.
Response time:
0.5 ms (2 ms mod.F01/G00)
Switching frequency:
1 kHz (250 Hz mod.F01/G00)
Indicators:
OUTPUT LED (YELLOW) excluding mod.G00
STABILITY LED (GREEN) (mod.B01/C01/C21/E01/F01)
POWER ON LED (GREEN) (mod.G00)
Setting:
sensitivity trimmer (mod.B01/C01/C21/E01/F01/T01)
Operating temperature:
-
25 … 55 °C
Storage temperature:
-
25 … 70 °C
Dielectric strength:
500 Vac / 1 min. between electronic parts and housing
Insulation resistance:
>20 M
/ 500 Vdc, between electronic parts and housing
Operating distance (typical values):
B01: 0.1…3.5 m on R2
C01: 0…60 cm
B01: 0.1…2 m on R2
C01: 0…35 cm
Emission type:
red (630 nm) (mod. E01) / red (660 nm) (mod.B01/T01)
infrared (880 nm) (mod. C01/C21/G00)
Ambient light rejection:
according to EN 60947-5-2
Vibrations:
0.5 mm amplitude, 10 … 55 Hz frequency, for every axis (EN60068-2-6)
Shock resistance:
11 ms (30 G) 6 shock for every axis (EN60068-2-27)
Housing material:
Nickel-plated brass
Lens material:
PMMA
Mechanical protection:
IP67 Type 1 enclosure
Connections:
M12 - 4 pole connector
Weight:
60 g. max. connector vers.
AtEx 2014/34/EU
I I 3G EX nA II T6 ;
I I 3D EX tD A22 IP67 T85°C
SETTING
Setting of S5N-
Mx…B01
Position the sensor and reflector on opposite sides.
Turn the sensitivity trimmer to the maximum position.
Moving the sensor both vertically and horizontally, determine the power on
and off points of the yellow LED (OUT) and then mount the sensor in the
middle of the points defined. Optimum operation is obtained when the
green LED (mod.B01) is ON and the yellow LED is OFF.
B01 models
: If necessary reduce sensitivity in order to detect very small
targets. In order to improve alignment, repeat the procedure detailed
above whilst progressively reducing the sensitivity.
Setting of S5N-
Mx…C01
Turn the sensitivity trimmer to minimum: the green LED is ON, the yellow
LED is OFF. Position the target to detect in front of the sensor or of the
fibre terminals. Turn the sensitivity trimmer clockwise until the yellow LED
turns ON
(Target detected state, pos.A).
Remove the target, the yellow
LED turns OFF. Turn the sensitivity trimmer clockwise until the yellow LED
turns ON
(Background detected state, pos.B).
The trimmer reaches maximum if the background is not detected.
Turn the trimmer to the intermediate position C, between the two positions
A and B. The green LED must be ON.
Datalogic S.r.l.
Via S. Vitalino 13 - 40012 Calderara di Reno - Italy
Tel: +39 051 3147011 - Fax: +39 051 3147205 - www.datalogic.com
Helpful links at www.datalogic.com:
Contact Us,
Terms and Conditions,
Support
.
The warranty period for this product is 36 months. See General Terms
and Conditions of Sales for further details.
For information about the disposal of Waste Electrical
and Electronic Equipment (WEEE), please refer to the
website at
© 2007 - 2019 Datalogic S.p.A. and/or its affiliates
ALL
RIGHTS RESERVED.
Without limiting the rights under copyright, no
part of this documentation may be reproduced, stored in or introduced into
a retrieval system, or transmitted in any form or by any means, or for any
purpose, without the express written permission of Datalogic S.p.A.
and/or its affiliates. Datalogic and the Datalogic logo are registered
trademarks of Datalogic S.p.A. in many countries, including the U.S.A.
and the E.U. All other trademarks and brands are property of their
respective owners. Datalogic reserves the right to make modifications
and improvements without prior notification.
82100631
1
Rev.
B
MIN
MAX
A
B
C