INSTALLATION
23
2
2.5 POSITIONING
Position the reader so that the distance from the reading window to the code surface
is that indicated in the figure below for your model.
Figure 23 - Positioning
Special models with different FOV and focus distance are available on request. Refer
to your local Datalogic distributor.
focus distance
115 mm
(4.52 in)
code surface
FOV
25 x 19 mm
(0.19 x 0.75 in)
HD
focus distance
155 mm
(6.10 in)
code surface
FOV
34 x 26 mm
(1.34 x 1.02 in)
SD
focus distance
110 mm
(4.33 in)
code surface
FOV
54 x 40 mm
(2.13 x 1.57 in)
LD
focus distance
210 mm
(8.26 in)
code surface
FOV
95 x 70 mm
(3.74 x 2.75 in)
MR