Error Codes
Quick Reference Guide
35
Error Codes
Upon startup, if the reader sounds a long tone, this means the
reader has not passed its automatic Selftest and has entered
FRU (Field Replaceable Unit) isolation mode. If the reader is
reset, the sequence will be repeated. The following table
describes the LED flashes/beep codes associated with an
error found.
Base Station Indications
Number of
LED Flashes/
Beeps
Error
Corrective Action
1
Configuration
Contact Helpdesk for
assistance
2
Interface PCB
6
Digital PCB
12
Imager
Indication
LEDS
Power-up Complete
Yellow LED on
Reader Disabled by the HOST or the
communication with HOST is not
established
Yellow LED blinking ~1Hz
Data/labels are transmitted to the
HOST
Yellow LEDs turned off for
100mSec
Programming Mode
Yellow LED blinks quickly
Configuration alignment with the HH
is in progress
Red LED blinks quickly
Battery charger in progress
Red LED on
Battery charger complete
Green LED on
Battery charger error
Green LED and Red LEDs
blink alternatively ~1Hz
No HH is placed on the cradle
Red and Green LEDs off