background image

Technical Features

26

   QUICKSCAN™ QD2590

TECHNICAL FEATURES

QuickScan™ QD2590

PHYSICAL FEATURES

Color

Black
White

Dimensions

Height 14.8 cm (5.8”)
Length 12.6 cm (4.96”)
Width 6.8 cm (2.7”)

Weight (without 
cable)

QD2590 approx. 145gr. (5.1oz.)

ELECTRICAL FEATURES

Power Supply

QD2590: 5 VDC ± 5%

Consumption

Operating (Typical): <450 mA @ 5V
Standby/Idle (Typical): <90 mA @ 5V

Max. Scan Rate

60 frames/sec

Reading Indicators

Top illumination, Good Read Spot, Beep

ENVIRONMENTAL FEATURES

Operating Tem-
perature

0 °C to + 50 °C (+32° F to +122 °F)

Storage Tempera-
ture

-40 °C to + 70 °C (-40 ° F to +158 °F)

Humidity

95% non condensing

Drop Resistance

IEC 68-2-32 Tested
1.5 m (4.9 ft)

Trigger Resistance

10 Mhits

ESD Protection

16 KV

Protection Class

IP52

Cable Length

Refer to 

www.datalogic.com

Содержание QuickScan QD2590

Страница 1: ...QuickScan QD2590 QUICK REFERENCE GUIDE General Purpose Corded Handheld Area Imager Bar Code Reader...

Страница 2: ...y be downloaded from the Data logic website www datalogic com If you visit our website and would like to make comments or suggestions about this or other Datalogic publica tions please let us know via...

Страница 3: ...System Pattern on 2D Matrix Symbol 6 Relative Size and Location of Aiming System Pattern on Linear bar code 7 Relative Size and Location of Green Spot 7 Parts of the Reader 8 Selecting the Interface T...

Страница 4: ...26 LED and Beeper Indications 30 Troubleshooting 31 Warranty 32 Ergonomic Recommendations 33 Cleaning Procedure 34 Common Cleaning Solutions 34 Cleaning enclosure and window surfaces 34 Technical Sup...

Страница 5: ...which it is intended for use in machine readable form only solely for End User s internal business purposes 1 2 End Users shall not distribute sublicense rent loan lease assign export re export resel...

Страница 6: ...any time Subject to the foregoing termination shall be effective upon notice to the other party In the event that this Agreement terminates for any rea son End User s license to use the Software will...

Страница 7: ...software hardware systems or other items not provided by Datalogic 7 Support End User may request support for Software from Datalogic at Datalogic s standard support fees and under Datalogic s standa...

Страница 8: ...ed in its native language form without modification or translation Please reference and review the above mentioned information to identify which Open Source Software packages have source code provided...

Страница 9: ...ty shall be entitled to reasonable attorneys fees both at trial and on appeal For Asia Pacific Countries The validity interpretation and construction of the Agreement shall be governed by and construe...

Страница 10: ...customers with the very latest in Datalogic soft ware technology The only exception to this policy is when the buyer has a signed contract with Datalogic that clearly defines the terms and conditions...

Страница 11: ...m developed with the unique intent to reduce visual stress of the operator during the daily scanning activities The outstanding aimer consists of two blue LED triangles pointing at the targeted bar co...

Страница 12: ...nside the field of view and switch the reading system from trigger mode to auto sense mode Decoding The QuickScan QD2590 reliably decodes all standard 1D linear and 2D bar codes including GS1 DataBar...

Страница 13: ...with integrated stand at a convenient angle allow ing hands free scanning of items It can also be used as a holder The holder cup can be positioned in any of the three angles shown in the figure belo...

Страница 14: ...below to connect and get your reader up and communicating with its host 1 Connect the Cable to the reader and the Host as shown below 2 Configure the Interface see page 9 3 Program the Reader starting...

Страница 15: ...take a paper clip and modify it as shown in the figure below Insert the end of the paper clip into the hole and press it to push on the clip that holds the connector As you apply pressure pull out th...

Страница 16: ...decoding codes The reader is equipped with an inter nal Motionix motion sensing function which activates the aiming system on device motion The intelligent aim ing system indicates the field of view w...

Страница 17: ...aller bars or ele ments mil size should be read closer to the unit Symbologies with larger bars or elements mil size should be read farther from the unit If the aiming system is centered and the entir...

Страница 18: ...ur application For interfaces other than those listed in this manual see the QuickScan QD2590 Product Reference Guide PRG available online at www datalogic com Interface Selection The reader will supp...

Страница 19: ...Unlike some other programming fea tures and options interface selections require that you scan only one programming bar code label DO NOT scan an ENTER EXIT bar code prior to scanning an interface se...

Страница 20: ...standard interface Select RS232 STD RS 232 Wincor Nixdorf Select RS232 WN RS 232 for use with OPOS UPOS JavaPOS Select RS 232 OPOS USB Com to simulate RS 232 standard interface Select USB COM STD1 1...

Страница 21: ...uring the Interface QUICK REFERENCE GUIDE 11 USB OEM USB OEM can be used for OPOS UPOS JavaPOS Select USB OEM USB COMPOSITE USB Composite Select USB Composite IBM46XX IBM46xx Port 9b Select IBM46xx Po...

Страница 22: ...figuring the Interface 12 QUICKSCAN QD2590 USB FOR TERMINALS USB HID POS Select USB HID POS USB Toshiba TEC Select USB Toshiba TEC USB FOR MAGELLAN SCANNERS USB for Magellans Select USB Magellan Scann...

Страница 23: ...AT PS 2 25 286 50 50Z 60 70 80 90 95 w Standard Key Encoding Select KBD AT Keyboard Wedge for IBM AT PS2 with standard key encoding but without external keyboard Select KBD AT NK AT PS 2 25 286 30 286...

Страница 24: ...with alternate key encoding USB Keyboard with standard key encoding AT PS 2 25 286 30 286 50 50Z 60 70 80 90 95 w Std Key Encoding Keyboard Wedge for IBM AT PS2 with standard key encoding but without...

Страница 25: ...lowing Country Modes U S Belgium Britain France Germany Italy Spain Sweden Default value Supports only the interfaces listed in the Country Mode feature description COUNTRY MODE ENTER EXIT PROGRAMMING...

Страница 26: ...QD2590 Supports only the interfaces listed in the Country Mode feature description COUNTRY MODE CONTINUED Country Mode Denmark Country Mode France Country Mode French Canadian Country Mode Germany Co...

Страница 27: ...UIDE 17 Supports only the interfaces listed in the Country Mode feature description COUNTRY MODE CONTINUED Country Mode Japanese 106 Key Country Mode Lithuanian Country Mode Norway Country Mode Poland...

Страница 28: ...the interface bar code from the Interfaces section select other options and cus tomize your reader through use of the programming bar codes available in the QuickScan QD2590 PRG Check the correspondin...

Страница 29: ...n Configure Other Settings Additional programming bar codes are available in the PRG to allow for customizing programming features If your installation requires different programming than the standard...

Страница 30: ...ing of the Numbers Lock Numlock key while in keyboard wedge interface This only applies to alternate key encoding interfaces It does not apply to USB keyboard Default value NUMLOCK ENTER EXIT PROGRAMM...

Страница 31: ...alternate key encoding key board is selected Default value READING PARAMETERS Move the reader toward the target and center the aiming pattern and illumination system to capture and decode the image Se...

Страница 32: ...you are holding the reader Aiming System A number of options for customizing control of the Aiming System are available See the QuickScan QD2590 PRG for more information and programming bar codes GOOD...

Страница 33: ...an on time 1 has elapsed Reading a label does not disable scanning Double Read Timeout1 pre vents undesired multiple reads while in this mode Trigger Hold Multiple When the trigger is pulled scanning...

Страница 34: ...g area If a predefined amount of movement is detected the white illumination switches on Scanning continues until a label is read or maximum scan on time is reached Default value SCAN MODE ENTER EXIT...

Страница 35: ...owledged or transmit ted to the host It is active only while the scanner is in Trig ger Single mode If the scanner switches to a different Read Mode Pick Mode is automatically disabled Default value M...

Страница 36: ...VDC 5 Consumption Operating Typical 450 mA 5V Standby Idle Typical 90 mA 5V Max Scan Rate 60 frames sec Reading Indicators Top illumination Good Read Spot Beep ENVIRONMENTAL FEATURES Operating Tem pe...

Страница 37: ...x 2453 um V Active Pixels 1280 H x 800 V Illumination System LED source Red Emission wavelength 617 nm Aiming System LED source Blue Emission wavelength 470nm Ambient Light Up to 100 000 lux Tilt Tol...

Страница 38: ...tion 10 2 The values are obtained with the item DOF Enhancement enabled Symbology DOF range Code 39 5 mil 0 5 25 0 cm 0 19 9 8 10 mil 0 5 38 cm 0 19 14 9 EAN13 13 mil 0 5 41 0 cm 0 19 16 1 PDF417 6 7...

Страница 39: ...d Codes The QuickScan QD2590 scanner is capable of decoding the following symbolo gies using multiple frames i e Multi Frame Decoding Datamatrix Inverse Datamatrix Datamatrix is configurable for the f...

Страница 40: ...LED blinks until enumeration with the host is completed Imager beeps four times at highest frequency and volume upon power up Good Read Upper green LED comes on for programmed time default LED behavi...

Страница 41: ...ode type Ensure imager is programmed to read the type of bar code scanned Refer to the PRG for more information Bar code label is unreadable Check the label to ensure it is not defaced Try scanning an...

Страница 42: ...le unit consumable items 7 use of counterfeit or replacement parts that are neither manu factured nor approved by Datalogic for use in Datalogic manufactured Products 8 any damage or malfunctioning ca...

Страница 43: ...orrect heights Reduce or eliminate vibration Reduce or eliminate direct pressure Provide adjustable workstations Provide adequate clearance Provide a suitable working environment Improve work procedur...

Страница 44: ...a recommended cleaning solution Be sure to apply the solution to your cloth first Wring excessive liquid from the cloth CAUTION Do not use abrasive pads or cleaning agents CAUTION Be sure to turn off...

Страница 45: ...website Log on to www datalogic com For quick access from the home page click on the search icon and type in the name of the product you re looking for This allows you access to download Data Sheets M...

Страница 46: ......

Страница 47: ......

Страница 48: ...ted in any form or by any means or for any purpose without the express written permission of Datalogic S p A and or its affiliates Datalogic and the Datalogic logo are registered trademarks of Datalog...

Отзывы: