Enter/Exit Programming Mode
LED and Beeper Indicators
74
QuickScan™ I QD24XX/QBT24XX/QM24XX
Good Read LED Duration
This feature specifies the amount of time that the Good Read LED remains on following a good
read. The good read LED on time can be set within a range of 100 milliseconds to 25,500 milli-
seconds (0.1 to 25.5 seconds) in 100ms increments. A setting of 00 keeps the LED on until the
next trigger pull.
See
in “References” for detailed instructions and examples for setting this feature.
$CLAGL00(CR)
Good Read LED Duration Setting =
Keep LED on until next trigger pull
$CLAGL
Select Good Read LED Duration Setting
To configure this feature, scan the ENTER/EXIT PRO-
GRAMMING MODE bar code above, then the bar code at
left followed by the digits from the Alphanumeric char-
acters in
representing your
desired character(s). End by scanning the ENTER/EXIT
bar code again.
Make a mistake? Scan the CANCEL bar code to abort and
not save the entry string. You can then start again at the
beginning.
~
CANCEL
DEFAULT
003 = Good Read LED
stays on for 300 ms.
NOTE
Indicators are dimmed during sleep.