QuickScan™
QBT2400
General Purpose Handheld
Area Imager Bar Code Reader
with Bluetooth® Wireless Technology
Quick Reference Guide
Страница 1: ...QuickScan QBT2400 General Purpose Handheld Area Imager Bar Code Reader with Bluetooth Wireless Technology Quick Reference Guide...
Страница 2: ...ting your Datalogic repre sentative Electronic versions may either be downloadable from the Datalogic website www datalogic com or provided on appropriate media If you visit our website and would like...
Страница 3: ...ing the Quickscan QBT2400 13 Linking the Reader 14 Link Datalogic RF Devices to Base 14 Linking to a Bluetooth Adapter in Serial Port Profile Mode 14 Linking to a Bluetooth Adapter in HID mode 15 Vari...
Страница 4: ...C RF Radiation Exposure Statement 42 Canadian Notice 42 Power Supply 43 Imager Labeling 43 WEEE Statement 45 Datalogic ADC Limited Factory Warranty 46 Warranty Coverage 46 Warranty Claims Process 46 W...
Страница 5: ...de secrets related to the Software b any other trade secrets marked appropriately or identified as proprietary or confidential and c any information that End User under the circumstances should recogn...
Страница 6: ...of the Datalogic Product exclusively for End User s internal business purposes End User shall take steps to protect the Propri etary Information no less securely than if it were End User s own intelle...
Страница 7: ...L DATALOGIC BE LIABLE TO END USER OR ANY THIRD PARTY FOR LOST PROFITS LOST DATA INTERRUPTION OF BUSINESS OR SERVICE OR FOR ANY OTHER SPECIAL CONSE QUENTIAL CONTINGENT INDIRECT INCIDENTAL PUNITIVE EXEM...
Страница 8: ...y of End User s assets are located 11 5 Attorneys Fees In the event an action is brought to enforce the terms and conditions of this Agreement the prevailing party shall be entitled to reason able att...
Страница 9: ...ntation of the symbol is not important Datalogic s exclusive patented Green Spot for good read feedback helps to improve productivity in noisy environments or in situations where silence is required W...
Страница 10: ...ion see page 14 4 Select the Interface Type see page 24 5 Configure the Reader starting on page 17 optional depends on settings needed Locking the Reader to the Base The Base Station provides a lockin...
Страница 11: ...m by pushing up the lever as far as it will go Figure 2 Lever in locked position it is good practice to put the scanner in the locked condition at the end of the working shift or when not in use for a...
Страница 12: ...ng 1 Remove the rubber Cable Stopper from the bottom of the Base Station 2 Securely plug the Power Cable and Interface I F Cable connectors into their respective ports in the underside of the Base Sta...
Страница 13: ...Host Connection Verify before connection that the reader s cable type is compatible with your host equipment The QuickScan QBT2400 reader can be set up to require a PIN code when connecting to the hos...
Страница 14: ...le from the keyboard and the remaining e nd at the key board port on the terminal PC Figure 4 Connecting to the Host Power Connection Plug the AC Adapter into an approved AC wall socket with the cable...
Страница 15: ...gure 6 QuickScan Base LEDs Table 1 Radio Base LEDs LED STATUS Power on Data Yellow On Base is powered Yellow Blinking Base receives data and commands from the Host or the Reader Charging Red On the Ba...
Страница 16: ...n on the bat tery follow the instructions in this manual Before using the Battery read Battery Safety in the following section Datalogic recommends annual replacement of rechargeable battery packs to...
Страница 17: ...the battery to get wet Do not apply voltages to the battery pack contacts WARNING In the event the battery pack leaks and the fluid gets into your eye do not rub the eye Rinse well with water and imm...
Страница 18: ...battery in direct sunlight or use or store the battery inside cars in hot weather Doing so may cause the battery to generate heat explode or ignite Using the battery in this manner may also result in...
Страница 19: ...nd other laws and regulations about the environment Replacing the Battery Pack 1 Using a coin or screwdriver unscrew the bottom of the battery pack until it is disengaged The battery pack will rise sl...
Страница 20: ...the new battery pack reverse the process 1 Insert the top of the new pack inside the reader s han dle 2 Rotate the battery pack downward while pressing the bottom side of the battery pack to seat secu...
Страница 21: ...system will be smaller when the reader is closer to the bar code and larger when it is farther from the code Symbolo gies with smaller bars or elements mil size should be read closer to the unit Symb...
Страница 22: ...s then scan the Unlink bar code before re linking to the new base Linking to a Bluetooth Adapter in Serial Port Profile Mode 1 Install any drivers provided with the Bluetooth adapter 2 Scan the Enable...
Страница 23: ...evices and select Datalogic Scanner If you receive an error message it may be necessary to disable security on the device 4 Use a text editor to see incoming data on the port designated by the compute...
Страница 24: ...numeric entry enter the required variable PIN Code by scanning the cor responding bar codes in the Hex Numeric Keypad sec tion at the back of this manual for alphanumeric entry Finish by scanning the...
Страница 25: ...de scan the desired parameter settings scan the ENTER EXIT bar code again to accept your changes which exits Programming Mode and returns the reader to normal operation Configure Other Settings Additi...
Страница 26: ...ode Read the configuration command label below for the HID Alt Mode feature Power Off Scan the bar code below to shut off power to the handheld until the next trigger pull PowerOff ENTER EXIT PROGRAMM...
Страница 27: ...e for IBM AT PS2 with standard key encoding but without external keyboard AT PS 2 25 286 30 286 50 50Z 60 70 80 90 95 without Alternate Key Keyboard Wedge for IBM AT PS2 without alternate key encoding...
Страница 28: ...ontinued Country Mode Croatia Country Mode Czech Republic Country Mode Denmark Country Mode France Country Mode French Canadian Country Mode Germany Supports only the interfaces listed in the Country...
Страница 29: ...ODE continued Country Mode Hungary Country Mode Italy Country Mode Japanese 106 key Country Mode Lithuanian Country Mode Norway Country Mode Poland Supports only the interfaces listed in the Country M...
Страница 30: ...ODE continued Country Mode Portugal Country Mode Romania Country Mode Spain Country Mode Sweden Country Mode Slovakia Country Mode Switzerland Supports only the interfaces listed in the Country Mode f...
Страница 31: ...only to keyboard wedge interfaces It does not apply when an alternate key encoding keyboard is selected The following bar codes can be used either while in HID mode when reader is connected using Blue...
Страница 32: ...aults and additional information associated with each interface proceed to the corresponding chapter in the Quick Scan Q2400 PRG Configuring the Interface Scan the programming bar code which selects t...
Страница 33: ...RS232 STD RS 232 Wincor Nixdorf Select RS232 WN RS 232 for use with OPOS UPOS JavaPOS Select RS 232 OPOS USB COM to simulate RS 232 standard interface Select USB COM STDa a Download the correct USB C...
Страница 34: ...PS 2 25 286 30 286 50 50Z 60 70 80 90 95 w Standard Key Encoding Select KBD AT Keyboard Wedge for IBM AT PS2 with standard key encoding but without external keyboard Select KBD AT NK AT PS 2 25 286 3...
Страница 35: ...KBD XT Keyboard Wedge for IBM Terminal 3153 Select KBD IBM 3153 Keyboard Wedge for IBM Terminals 31xx 32xx 34xx 37xx make only keyboard Select KBD IBM M Keyboard Wedge for IBM Terminals 31xx 32xx 34xx...
Страница 36: ...en configured through the base See Country Mode on page 19 for programming bar codes and informa tion Caps Lock State This option specifies the format in which the reader sends character data See Caps...
Страница 37: ...red beam to decode the barcode label The aiming system will briefly switch off during the acquisition time and if no code is decoded will switch on again before the next acquisition The illuminator w...
Страница 38: ...d by a good read green spot Use the bar codes below to specify the duration of the good read pointer beam after a good read ENTER EXIT PROGRAMMING MODE Green Spot Duration Disable Green Spot is Off Gr...
Страница 39: ...nd released scanning is activated until programmable duration1 has elapsed or the trigger has been pulled again to transition to another state Double Read Timeout1 prevents undesired multiple reads wh...
Страница 40: ...32 QuickScan QBT2400 SCAN MODE ENTER EXIT PROGRAMMING MODE Scan Mode Trigger Single Scan Mode Trigger Hold Multiple Scan Mode Trigger Pulse Multiple Scan Mode Flashing Scan Mode Always On Scan Mode S...
Страница 41: ...s in Trigger Single mode If the scanner switches to a different Read Mode Pick Mode is automatically disabled Multiple Labels in a Volume Enables disables the ability of scanner to decode multiple lab...
Страница 42: ...ly 200 g reader 230 g base charger Electrical Characteristics Battery Type Li Ion battery pack Typical charge time for full charge from full discharge 6 hours with Host Power through the micro USB cab...
Страница 43: ...3 mils DOF based on EAN All other 1D codes are Code 39 All labels grade A typical environmental light 20 C label inclination 10 Symbology Code 39 5mil 0 2 5 9 0 5 15cm 10mil 0 8 7 0 22cm 20mil up to 1...
Страница 44: ...ztec Datamatrix Inverse Datamatrix Data matrix is configurable for the following parameters Normal or Inverted Square or Rectangular Style Data length 1 3600 char acters Maxicode QR Codes QR Micro QR...
Страница 45: ...to concrete Ambient Light Immunity Up to 100 000 Lux Contaminants Spray rain Dust particulates IEC 529 IP42 scanner only ESD Level 16 KV Regulatory Electrical Safety UL 60950 CSA C22 2 No 60950 IEC 60...
Страница 46: ...highest fre quency and vol ume upon power up Good Read Beep A label has been successfully scanned by the reader LED behavior for this indication is configurable via thefeature Good Read When to Indica...
Страница 47: ...Label A label has been rejected N A Reader sounds three times at lowest fre quency and cur rent volume Label Program ming Mode Accep tance of Partial Label In cases where multiple labels must be scann...
Страница 48: ...Configuration Contact Helpdesk for assis tance 2 Interface PCB 6 Digital PCB 12 Imager Indication LEDs Power up Complete Yellow LED on Reader Disabled by the HOST or the communication with HOST is no...
Страница 49: ...uipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful...
Страница 50: ...dio electriques depassant les limites applicables aux appareils numeriques de la classe B prescrites dans le Reglement sur le brouillage radioelectrique edicte par le ministere des Commu nications du...
Страница 51: ...ment purposes only Please view the labels on your product for actual details as they may vary from those depicted Atenc on Caracter sticas de la fuente de alimentaci n el ctrica Entrada 100 240 Vca mi...
Страница 52: ...ead Pb Mercury Hg Cadmium Cd Hexavalent Chromium Cr VI Polybrominated biphenyls PBB Polybrominated diphenyl ethers PBDE PART Cable X O O O O O Printed Circuit Board Assy X O O O O O Assembly Module X...
Страница 53: ...nternet www datalogic com German Informationen zur Entsorgung von Elektro und Elektronik Altger ten WEEE erhalten Sie auf der Webseite www datalogic com Spanish Si desea informaci n acerca de los proc...
Страница 54: ...c to scrap all parts removed from the repaired prod uct The warranty period shall extend from the date of ship ment from Datalogic for the duration published by Datalogic for the product at the time o...
Страница 55: ...personnel or its authorized represen tatives ii any claimed defect failure or damage which Data logic determines was caused by faulty operations improper use abuse misuse wear and tear negli gence im...
Страница 56: ...FROM DELAYS IN THE REPLACEMENT OR REPAIR OF PRODUCTS UNDER THE ABOVE THE REMEDY SET FORTH IN THIS WARRANTY STATE MENT IS THE CUSTOMER S SOLE AND EXCLUSIVE REMEDY FOR WARRANTY CLAIMS UNDER NO CIRCUMSTA...
Страница 57: ...orrect heights Reduce or eliminate vibration Reduce or eliminate direct pressure Provide adjustable workstations Provide adequate clearance Provide a suitable working environment Improve work procedur...
Страница 58: ...d as needed to ensure a good connection Be sure to unplug the reader and base before cleaning Use a soft dry cloth to clean the product If the product is very soiled clean it with a soft cloth moisten...
Страница 59: ...ing Datalogic Aladdin a multi platform utility pro gram that allows device configuration using a PC It provides RS 232 interface configuration as well as bar code printing Service Support Technical Su...
Страница 60: ...Hex Numeric Keypad 52 QuickScan QBT2400 Hex Numeric Keypad Use the bar codes that follow to enter numbers as you would select digits characters from a keypad 0 1 2 3 4 5...
Страница 61: ...Hex Numeric Keypad Quick Reference Guide 53 Hex Numeric Keypad continued 6 7 8 9 A B...
Страница 62: ...E F For HID Variable Pin Code only If you make a mistake scan the CANCEL barcode below to abort and not save the entry string You can then restart Finish by scanning the Exit HID Variable PIN Code lab...
Страница 63: ...Cette d claration repose sur la conformit des produits aux normes suivantes Diese Erkl rung basiert darauf da das Produkt den folgenden Normen entspricht Esta declaraci n se basa en el cumplimiento de...
Страница 64: ...he Datalogic logo are registered trademarks of Datalogic S p A in many countries including the U S A and the E U Datalogic ADC Inc 959 Terry Street Eugene OR 97402 USA Telephone 1 541 683 5700 Fax 1 5...