RF FEATURES
PRODUCT REFERENCE GUIDE
339
RF FEATURES
Automatic Configuration Update
When this feature is enabled, the base station and reader will keep their configurations
synchronized. If a reader's configuration is altered by reading programming labels, this
change is automatically transferred and updated in a linked base station. Likewise, if the
base station's configuration is changed using Aladdin or by host commands, then the
reader's configuration will automatically be updated if this feature is enabled.
RF Address Stamping
Source Radio Address Delimiter Character
This option specifies the delimiter character to be placed between the label data and
radio address when address stamping is enabled.
Follow these instructions to select the delimiter character:
1. Determine the desired character, then find its hexadecimal equivalent on the ASCII
Chart on
. A setting of 00 specifies no delimiter character.
2. Scan the ENTER/EXIT PROGRAMMING MODE bar code to enter Programming
Mode.
3. Scan the bar code: SET SOURCE RADIO ADDRESS DELIMITER CHARACTER.
4. Scan the appropriate two digits from the keypad in
, that represent the
hexadecimal characters which were determined in the steps above. You will hear a
two-beep indication after the last character.
5. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit.
Table 26 Source Radio Address Delimiter Character Setting Examples
NOTE: This feature only applies if "
Source Radio Address Transmission" on
is enabled
NOTE: If you make a mistake before the last character, scan the CANCEL
bar code to abort and not save the entry string. You can then start again at
the beginning.
STEP
ACTION
EXAMPLES
1
Desired Setting
No delimiter
character
, (comma)
- (dash)
/ (slash)
2
Scan ENTER/EXIT PROGRAMMING MODE
3
Scan SET SOURCE RADIO ADDRESS DELIMiTER CHARACTER
4
Scan Two Characters From
‘0’ and ‘0’
‘2’ and ‘C’
‘2’ and ‘D’
‘2’ AND ‘F’
5
Scan ENTER/EXIT PROGRAMMING MODE
Содержание PowerScan Series
Страница 100: ...84 POWERSCAN PD PM PBT9600 CONFIGURATION USB OEM INTERFACE SECTION CONTENTS USB OEM Device Usage...
Страница 399: ...SAMPLE BARCODES PRODUCT REFERENCE GUIDE 383 Interleaved 2 of 5 Code 32 Codabar Code 93 Code 11 12345678901231...
Страница 402: ...SAMPLE BARCODES 386 POWERSCAN PD PM PBT9600 2D Barcodes continued QR Code 35900G9 Micro QR Code 123456 UCC Composite...
Страница 404: ...KEYPAD 388 POWERSCAN PD PM PBT9600 1 2 3 4 5 6 7 8 9 CANCEL...