ENTER/EXIT PROGRAMMING MODE
1D SYMBOLOGIES
196
POWERSCAN™ PD/PM/PBT9600
ABC Codabar Dynamic Concatenation Timeout
This parameter specifies the timeout in 10-millisecond ticks used by the ABC Codabar
Dynamic Concatenation Mode. The timeout can be set within a range of 05 to 255 in
10ms increments. A setting of zero specifies no delay.
ABC Codabar Force Concatenation
When ABC Codabar Concatenation is enabled and Force Concatenation is disabled, both
Codabar stand alone labels and ABC Codabar concatenated labels are transmitted.
When ABC Codabar Concatenation is enabled and Force Concatenation is enabled only
ABC Codabar concatenated labels are transmitted while Codabar stand alone labels are
not transmitted.
Force Concatenation has no effect if the ABC Codabar Concatenation is disabled. The
Force Concatenation mode has effect both in Static and Dynamic Concatenation Modes.
Select ABC Codabar Dynamic Concatenation
Timeout Setting
$CCBDT
To configure this feature, scan the ENTER/EXIT PRO
-
GRAMMING MODE bar code above, then the bar
code at left followed by the digits from the Alphanu
-
-
ing your desired character(s). End by scanning the
ENTER/EXIT bar code again.
Make a mistake? Scan the CANCEL bar code to abort
and not save the entry string. You can then start
again at the beginning.
CANCEL
Timeout = 20 (200 msec)
$CCBFC00
ABC Codabar Force Contatenation = Disable
ABC Codabar Force Concatenation = Enable
$CCBFC01
Содержание PowerScan Series
Страница 100: ...84 POWERSCAN PD PM PBT9600 CONFIGURATION USB OEM INTERFACE SECTION CONTENTS USB OEM Device Usage...
Страница 399: ...SAMPLE BARCODES PRODUCT REFERENCE GUIDE 383 Interleaved 2 of 5 Code 32 Codabar Code 93 Code 11 12345678901231...
Страница 402: ...SAMPLE BARCODES 386 POWERSCAN PD PM PBT9600 2D Barcodes continued QR Code 35900G9 Micro QR Code 123456 UCC Composite...
Страница 404: ...KEYPAD 388 POWERSCAN PD PM PBT9600 1 2 3 4 5 6 7 8 9 CANCEL...