INTERLEAVED 2 OF 5 (I 2 OF 5)
ENTER/EXIT PROGRAMMING MODE
PRODUCT REFERENCE GUIDE
167
INTERLEAVED 2 OF 5 (I 2 OF 5)
The following options apply to the I 2 of 5 symbology.
I 2 of 5 Enable/Disable
When disabled, the reader will not read I 2 of 5 bar codes.
I 2 of 5 Check Character Calculation
This option enables/disables calculation and verification of an optional I 2 of 5 check
character.
CAUTION: When reading this symbology, the settings for I 2 of 5 Length
Control AND I 2 of 5 Check Character Calculation MUST be enabled to
increase decoding safety.
$CI2EN00
I 2 of 5 = Disable
I 2 of 5 = Enable
$CI2EN01
$CI2CC00
I 2 of 5 Check Character Calculation = Disable
I 2 of 5 Check Character Calculation
= Calculate Std Check (Modulo 10 no AR)
$CI2CC01
$CI2CC02
I 2 of 5 Check Character Calculation
= Calculate German Parcel Check
Содержание PowerScan Series
Страница 100: ...84 POWERSCAN PD PM PBT9600 CONFIGURATION USB OEM INTERFACE SECTION CONTENTS USB OEM Device Usage...
Страница 399: ...SAMPLE BARCODES PRODUCT REFERENCE GUIDE 383 Interleaved 2 of 5 Code 32 Codabar Code 93 Code 11 12345678901231...
Страница 402: ...SAMPLE BARCODES 386 POWERSCAN PD PM PBT9600 2D Barcodes continued QR Code 35900G9 Micro QR Code 123456 UCC Composite...